Runco SP-42DHD, SP-60DHD, SP-50DHD manual Service, Should be used by ISF-certified technicians only

Page 54

Service

Service

Test Video

Input Names

Remote Control

Analog Out Mode

Display Device

HD Format

Triggers

Miscellaneous

Resolution

System Reset

Restore Saved Settings

Noise Filter: To apply noise filtering to the input signal, select Noise Filter from the Input Color menu. The Noise Filter is useful for clearing up noisy images from 480i video sources.

Use the left- or right-arrow buttons to select the desired amount of noise reduction, keeping in mind that higher settings (which reduce high frequencies) may also “soften” the image.

ISF Day - Display Color: Refer to ISF Night - Display Color.

ISF Day - Input Image: Refer to ISF Night - Input Image.

ISF Day - Input Color: Refer to ISF Night - Input Color.

Save ISF Settings: Whenever you make a change to the ISF settings, you should always save it. Select Save ISF Settings from the ISF Calibration menu to do this. In the event you ever have to perform a System Reset, you can restore the saved ISF settings by selecting Restore Saved Settings in the Service menu. (System Reset and Restore Saved Settings are described on page 47.)

Output Shift: The controls in the Output Shift menu are similar to those in the Input Position menu, except that they change the characteristics of the output signal. These settings are saved independently for each aspect ratio.

Splash Configure: Use the Splash Configure menu to customize the appearance of the start-up message that appears on the vacuum fluorescent display upon power-up. You can have the PlasmaWall display the owner’s name, your name, the phrase “ISF Calibrated” and/or any other string, up to 20 characters in length.

Use the up or down cursor button to select a character. Use the right and left cursor buttons to change the cursor position. Press MENU when you have finished entering text. Then, check the “Splash Enable” box to have the PlasmaWall display the information you enter here when it is turned on.

OSD Position: Select OSD Position, press ENTER and use the arrow buttons to change the size and position of the OSD controls.

Use the Service menu to access advanced display configuration settings. This menu

should be used by ISF-certified technicians only.

You must enter a passcode to access the Service menu.

Note

Test Video: Select Test Video from the Service Menu to access the internal test patterns on the PlasmaWall. Four patterns are available, consisting of white/gray or colored bars. These are useful for calibrating other theater source components (DVD player, HD tuner etc.) that have their own picture controls.

Press MENU to exit test pattern mode.

44

PlasmaWall SP Series Owner’s Operating Manual

Image 54
Contents SP-42DHD SP-50DHD SP-60DHD Page Three Year Limited Warranty For Plasma DisplaysRIGHTS, Limits and Exclusions Runco INTERNATIONAL, INC Safety Precautions Table of Contents Appendix A. PlasmaWall Service Remote Control Maintenance and TroubleshootingSpecifications OperationList of Figures List of Figures Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Indicators Controls and FunctionsPlasmaWall at a Glance PlasmaWall Model SP-42DHD Rear Panel PlasmaWall Model SP-50DHD Rear Panel PlasmaWall Model SP-60DHD Rear Panel External Speaker Output Right Main Power SwitchDigital RGB Input 2 DVI-D External Speaker Output LeftRunco Icon Power ButtonDHD Controller Front Panel IR SensorEnter Button UP ButtonLeft Button Down ButtonDVI OUT Component Video RCA connectorsDHD Controller Rear Panel Inputs 3. DVI 1 / DVI 2 DigitalComposite Video Input RS-232 Control PortMain AC Fuse DHD Controller Remote Control DHD Controller Remote ControlLight IR Output IndicatorEnter MenuISF Night CinemaSVC ISF DAYInstallation Remote ControlOther surfaces Quick Setup Step Procedure For Details, refer toHigh-Altitude Operation InstallationConsiderations Mounting the PlasmaWallAmbient Light VentilationInstallation Connecting PlasmaWall to the DHD Controller Connections to the PlasmaWall and DHD ControllerRS-232 Connection from the DHD Controller to the PlasmaWall DVI Connections See Figure Connecting SourceComponents to the DHD DVI Source DVD Player or HD Tuner with Hdmi or DVI outDigital DTV RGB Connections See Digital DTV RGB ConnectionsRefer to Computer/Video Signal Compatibility on page 64 for Analog Computer RGB Connections See FigurePersonal Computer Composite/S-Video/Component Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcConnecting 12-Volt Trigger Outputs to External Equipment RS-232 ControllerConnection 11. Installing the Cable Ties Turning on the Power OperationYou must enter a passcode to access the Service menu Operation Using the On-Screen Menus Input Source ISF PresetsService Aspect RatioAspect Ratio Main MenuInput Source HD Pass Thru 1 HD Pass ThruAspect Ratio Settings Remote Aspect Ratio Control Description KeyPicture Picture Brightness Contrast Color Tint SharpnessTypical Gray Bar Pattern for Adjusting Contrast Gray Yellow Cyan Green Magenta Red Blue Input Position Input Position Left/Right Up/Down Width Height OverscanInformation ISF PresetsISF Presets ISF Night ISF Day Custom Save Factory Default Serial Number Hardware Firmware 0002.034B Date Nov 25Gain/Offset Refer to ISF Night Display Color, above CalibrationService Should be used by ISF-certified technicians onlyInput Names Restore Composite Video Component SD HD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Cleaning the Display Panel Body and Remote Control Maintenance and TroubleshootingCleaning Cleaning the ScreenTroubleshooting Tips Symptom Possible Causes SolutionComputer/Video Signal Maintenance and Troubleshooting Serial Communications Letterbox EnterInput Selection Commands CommandValue Description Min/max Stored? Power On/Off Commands Aspect Ratio CommandsImage Preset Commands Value Description Min/max Stored? Input Position Commands Output Shift CommandsBkgnd Command Parameter min/max Value Stored? Description Enter keyModel SP-42DHD SpecificationsPlasmaWall Specifications Model SP-50DHDDHD Controller Specifications Dimensions PlasmaWall14.8 34.3 49.1 M8 Screw Horiz Computer/Video Signal CompatibilityInput Refresh Rate Resolution Remarks KHz56.0 45.1 Specifications Figure A-1. PlasmaWall Service Remote Control OverviewRGB-HD RGB SetupAspect Ratio DVI-DService/Setup Menu Video NR NoiseReduction PlasmaWall Service Remote Control Page Runco CL-810 Owner’s Operating Manual