VXI user manual Option 1 SVM2608-01

Page 21

www.vxitech.com

OPTION 1 - SVM2608-01

NUMBER OF CHANNELS

 

2

VMEBUS INTERFACE

 

 

Address Mode

A32

Data Transfer Mode

D16 or D32

SAMPLING RATE

 

 

Range

 

7.15 Samples/s to 20.0 MSamples/s

Resolution

 

8.333 ns

Accuracy

1%

MEMORY

 

 

 

1 MSamples per channel

VOLTAGE MEASUREMENTS

 

 

Range

±0.5 V, ±1.0 V, ±2.0 V, ±5.0 V, ±10.0 V, ±20.0 V

Resolution

Range/211

Accuracy

1%

INPUT IMPEDANCE

 

 

 

1 MΩ or 50 Ω (software selectable)

INPUT MODE

 

 

 

ac or dc (software selectable)

INPUT FILTER

 

 

 

 

5 MHz (-3 dB)

TRIGGER LEVELS

 

 

Internal

 

trigger level determined by selected voltage range (see Voltage Measurement above)

Range

 

Trigger level resolution

 

Full scale/211

Level accuracy

1%

External

 

 

Range

 

-10 V to +10 V

Trigger level resolution

 

4.88 mV

Level accuracy

1%

DELAYED TRIGGER

 

 

Range

 

0 samples to (224 -1) samples

Resolution

 

1 sample

TRIGGER ACCURACY

 

 

 

1%

EXTERNAL TRIGGER ACCURACY

 

1%

TIMEOUT

 

 

Range

 

10 µs to 227 hrs

Resolution

 

10 µs to 100 s

WARM-UP TIME

10 min

MTBF

80,000 hrs (based on 20% Ground Mobile, 80% Ground Fixed environment, T ≥ 52°C)

SVM2608 Introduction

21

Image 21
Contents SVM2608 VXI Technology, Inc Table of Contents Self Test Command Limitation of Warranty WarrantyCertification Restricted Rights LegendSteve Mauga, QA Manager EMCTerms and Symbols Service should only be performed by qualified personnelUse Proper Power Cord Use Proper Power SourceGround the Product Avoid Electric ShockOperating Conditions Improper UseVXI Technology Cleveland Instrument Division VXI Technology World HeadquartersVXI Technology Lake Stevens Instrument Division Technical SupportVXI Technology, Inc SVM2608 Preface Overview IntroductionScale Triggering Acquiring DataLinear Mode Delayed TriggerPre-Trigger Commands Fifo ModeCalibrations Test BusOption SVM2608 Block Diagram Physical Description SVM2608 Environmental SpecificationsGND CH1I CH3I Front Panel Interface WiringGND CH1I+ GND CH3I+ Exttrigin CH0I CH2IMtbf SVM2608 SpecificationsOption 1 SVM2608-01 VXI Technology, Inc SVM2608 Introduction Setting the Chassis Backplane Jumpers Calculating System Power and Cooling RequirementsRotary Switch Locations Setting the Base AddressExample Divide DecimalMSB LSB Module INSTALLATION/REMOVAL Switch to C and the front switch toFunction Offset Device Memory MapsReserved Register OffsetMS = Most Significant LS = Least Significant SVM2608 A32 Register MAP0x72 Command Register Channel 0x74 Databyte Ordering Determining the Register Address Accessing the Registers Description of RegistersSysfailctl INTLVL2 Force Trigger, Start Register 0x02 Read & WriteHSTRIGSRC2 EXT Trig SlopeTimeoutctl ReservedExternal Trigger Level 0x06 Read & Write 4WIREOHMS 2WIREOHMSLINEAR/FIFO ATTN-GAIN1-GAIN0Sample Rate 0x0C, 0x34, 0x5C, 0x84 Read & Write Sample Rate 0x0E, 0x36, 0x5E, 0x86 Read & WriteKHz Channels 0-3/5 MHz Channels 4-5 LPF Control This bit Sample Rate, High-Speed 0xAE, 0xD6 Read & Write Sample Rate, High-Speed 0xAC, 0xD4 Read & WriteTimeout 0x1C, 0x44, 0x6C, 0x94, 0xBC, 0xE4 Read & Write Fifo Data 0x24, 0x4C, 0x74, 0x9C, 0xC4, 0xEC Read Only Fifo Data 0x26, 0x4E, 0x76, 0x9E, 0xC6, 0xEE Read OnlyReserved Registers 0xF8 0xFC Trigger Delay = Measurement Commands Microprocessor CommandsCaptured Data Calculations Self Test Command Resistance Measurement Offset MethodResistance Measurement Dynamic Method Example Preset Setting Measurement CommandsSample Points Calibration CommandsSample Rate Trigger Event Forced TriggerPage Error Processing There are no errors in the queue Diagnostic Commands Changes become effective the next time the module powers up Examples Example 2 Setting Channel 2 to Acquire 200,000 SamplesExample 3 Setting Channel 2 to Pre-acquire 100,000 Samples Timeout Register = Timeout Base * 213 + Timeout Counter Timeout Counter = Timeout / Timeout Base ClockVXI Technology, Inc SVM2608 Programming Data Swapping Example Appendix aVXI Technology, Inc SVM2608 Appendix a Index