VXI SVM2608 user manual Self Test Command

Page 4

 

VXI Technology, Inc.

Measurement Commands

41

Captured Data Calculations

42

Resistance Measurement – Offset Method

43

Resistance Measurement – Dynamic Method

43

Self Test Command

43

Preset Setting Measurement Commands

44

Calibration Commands

45

Error Processing

47

Diagnostic Commands

49

Examples

51

Example 1: Setting the Channel 2 and 4 Sample Rate to 123 ms (8.13 kHz)

51

Example 2: Setting Channel 2 to Acquire 200,000 Samples

51

Example 3: Setting Channel 2 to Pre-acquire 100,000 Samples

52

Example 4: Setting Channel 2 to Delay Acquisition by 1,500,000 Samples

52

Example 5: Setting Channel 2 and 4 Timeout Register to Timeout after 2.5 s

53

APPENDIX A

55

APPENDIX A

55

Data Swapping Example

55

INDEX

57

4

SVM2608 Preface

Image 4
Contents SVM2608 VXI Technology, Inc Table of Contents Self Test Command Warranty Limitation of WarrantyCertification Restricted Rights LegendEMC Steve Mauga, QA ManagerService should only be performed by qualified personnel Terms and SymbolsUse Proper Power Cord Use Proper Power SourceAvoid Electric Shock Ground the ProductOperating Conditions Improper UseVXI Technology World Headquarters VXI Technology Cleveland Instrument DivisionVXI Technology Lake Stevens Instrument Division Technical SupportVXI Technology, Inc SVM2608 Preface Introduction OverviewScale Acquiring Data TriggeringDelayed Trigger Linear ModePre-Trigger Fifo Mode CommandsCalibrations Test BusOption SVM2608 Block Diagram SVM2608 Environmental Specifications Physical DescriptionFront Panel Interface Wiring GND CH1I CH3IGND CH1I+ GND CH3I+ Exttrigin CH0I CH2ISVM2608 Specifications MtbfOption 1 SVM2608-01 VXI Technology, Inc SVM2608 Introduction Calculating System Power and Cooling Requirements Setting the Chassis Backplane JumpersSetting the Base Address Rotary Switch LocationsDivide Decimal ExampleMSB LSB Switch to C and the front switch to Module INSTALLATION/REMOVALDevice Memory Maps Function OffsetReserved Register OffsetSVM2608 A32 Register MAP MS = Most Significant LS = Least Significant0x72 Command Register Channel 0x74 Databyte Ordering Determining the Register Address Description of Registers Accessing the RegistersSysfailctl Force Trigger, Start Register 0x02 Read & Write INTLVL2HSTRIGSRC2 EXT Trig SlopeReserved TimeoutctlExternal Trigger Level 0x06 Read & Write 2WIREOHMS 4WIREOHMSLINEAR/FIFO ATTN-GAIN1-GAIN0Sample Rate 0x0E, 0x36, 0x5E, 0x86 Read & Write Sample Rate 0x0C, 0x34, 0x5C, 0x84 Read & WriteKHz Channels 0-3/5 MHz Channels 4-5 LPF Control This bit Sample Rate, High-Speed 0xAC, 0xD4 Read & Write Sample Rate, High-Speed 0xAE, 0xD6 Read & WriteTimeout 0x1C, 0x44, 0x6C, 0x94, 0xBC, 0xE4 Read & Write Fifo Data 0x26, 0x4E, 0x76, 0x9E, 0xC6, 0xEE Read Only Fifo Data 0x24, 0x4C, 0x74, 0x9C, 0xC4, 0xEC Read OnlyReserved Registers 0xF8 0xFC Trigger Delay = Microprocessor Commands Measurement CommandsCaptured Data Calculations Resistance Measurement Offset Method Self Test CommandResistance Measurement Dynamic Method Preset Setting Measurement Commands ExampleCalibration Commands Sample PointsSample Rate Trigger Event Forced TriggerPage Error Processing There are no errors in the queue Diagnostic Commands Changes become effective the next time the module powers up Example 2 Setting Channel 2 to Acquire 200,000 Samples ExamplesExample 3 Setting Channel 2 to Pre-acquire 100,000 Samples Timeout Counter = Timeout / Timeout Base Clock Timeout Register = Timeout Base * 213 + Timeout CounterVXI Technology, Inc SVM2608 Programming Appendix a Data Swapping ExampleVXI Technology, Inc SVM2608 Appendix a Index