Pioneer PDK-50HW3 specifications OK button, Calibration Detail-1

Page 29

4. Installing and Using Software

[Overview]

Easy Setting: Apply preset calibration by specifying currently displayed screen mode.

The following modes are available.

1)FULL mode

2)4:3 mode

3)DOT BY DOT mode

Notes:

Check the screen mode before making settings.

Be sure to check the “SIGNAL FORMAT” setting of the plasma display.

(Read the initial setup instructions for the plasma display in the section “Precautions” in this Technical Manual.)

Only modes with a preset screen resolution value are enabled. Easy Setting is not available when there is no preset resolution.

Adjustment of the plasma display and video card may shift cursor position relative to input location.

Detaile Setting: Use to perform manual calibration of pen tip and cursor position.

Use one of the following calibration methods.

1)Detail-1 (4-point calibration)

2)Detail-2 (vertical calibration)

Notes:

Detail-2 is available only in the “PARTIAL” plasma display mode.

Use Detail-1 when Easy Setting is not available.

OK button:

Press to start selected calibration mode. When select Detail-1 or 2, changes the respective screen.

Cancel button:

Cancels selected calibration.

Apply button:

Temporarily applies the preset value without closing the current window. This button is available only

 

during Easy Setting. Move to the pen to check whether or not the preset value is available.

Note:

The availability or otherwise of screen items depends on current screen resolution.

a) Calibration (Detail-1)

Tap the four points in the screen shown below to perform detailed calibration.

Follow the on-screen calibration instructions and accurately touch the center of the red crosses.

Notes:

Use the mouse to make the settings in this screen.

The set calibration is stored and is available atsubsequent startups.

The calibrated value differs with resolution. However, the set calibrated value becomes available again when you return to the resolution for which the value was set.

29

Image 29
Contents Technical Manual Ver Changes from PDK-50HW2A to PDK-50HW3 Pioneer badge need no longer be removed during installationScan device changes New designUSB cable clip location Flash pattern of the power indicator has changedLocation of the PEN-NORMAL mode selector switch has changed Changes made to the pen Pen stand modificationsChanges in the driver Pen stand has been modifiedMiddle button 3-button emulation is supported Changes in serviceService Mode has been improved Contents Specifications SpecificationsSystem plasma display and handwriting device specifications Separate plasma display PDP-504CMX specificationsHandwriting device PDK-50HW3 AccessoriesPlasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Outline Drawing External dimension drawingSide panel Plasma displayPDK-50HW3 as seen from rear PDK-50HW3 center line USB cable exitConfirming Battery Life ¶ External dimension drawingName and Function of Parts & Pin Layout ¶ Name and function of partsInstallation Site Installation SiteInstallation Conditions List showing compatibility of standard metal fittingsSpecial installations Installation of multiple systems Installation precautionsExposure to direct sunlight Ultrasonic wavesUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryConnecting the plasma display to a computer Computer Setup ExamplePrecautions regarding computer setup CheckProcedures for setting the plasma display Adjusting the Plasma DisplayScreen burning Installing the DriverConnecting a Scan Device to a Computer Check in Service Mode How to Use Cable ClipCheck in Normal mode Check in PEN mode¶ Alignment of pen tip and cursor position Final Check Installing the CBdrvU Ver .0 Driver Installing and Using SoftwareInstallation procedures Operating environmentUninstall procedures Using the DriverChanges from CBdrv Ver .4 to CBdrvU Ver CBdrvU operationsHot key operations Scan device off screen Scan device setup screenSelect Calibration dialog Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupState display Test ModeTest chart display About CBdrvU Disabling CBdrvUExit Disabling CBdrvUTask tray display RotateCBdrvU operation Precautions Installing and Using Software Service Mode display Using Driver and Service ModeScreen items Status displayed after pressing SelfTest buttonInstalling and Using Software Readjustment of White Balance Maintenance and CleaningScreen Name Part NumberReplacing the pen tip Pen battery lifeTo make waveform observations Internal DIP Switch SettingsTo lock device in the Normal mode Hardware-Related Q&A Page Driver Software-Related Q&A Page Plasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S TroubleshootingProblem Possible Solution Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionLow scan mode ResolutionHigh scan mode Capabilities of the Handwriting Device