7. Q & A

Q: Can the PDK-5008 mobile cart be used?

A: No, since it does not remain stable during writing. Use of the PDK-5009, PDK-5014, PDK-MC01 is recommended.

Q: Why is it possible to write letters with a finger while the PEN mode is set?

A:Is there a same system installed in the proximity? When more than one system is used in proximity, the ultrasound emitted from a special pen may interfere with the adjacent systems. In this case, when a special pen is used, the adjacent system may respond to it and accept writing by a finger even when it is in the PEN mode. To prevent this, install the adjacent system outside the interference area or set it to the NORMAL mode.

7.2 Driver Software-Related Q&A

Q:Which are the Operating Systems compatible with CBdrvU?

A:They include, Windows 2000 Professional and Windows XP. It is not compatible with Unix, Linux and Macintosh.

Q: Can the CBdrvU and its predecessor CBdrv drivers coexist?

A:Yes, if they are installed in different folders. PDK-50HW3 supports only CBdrvU ver. 2.0.

Having both CBdrvU ver. 2.0 and CBdrv installed does not offer any advantages. If they are used on the same volume, two separate hot keys will be required. It is recommended that CBdrv, the old version, be uninstalled and that only CBdrvU ver. 2.0 be installed.

Q: What to do when double-clicking does not work well?

A:Widen the effective area or change the double-clicking speed setting (in the MOUSE setting item in the setup menu). However, if the effective area is too large, it would become difficult to select a cell in Excel, etc. The effective area should therefore be set by considering this tradeoff.

Q: What to do if operations on the browser do not work well?

A:When the special pen is used on a display of a browser such as IE (Internet Explorer), clicking with the pen tip does not always jump to the link destination successfully. This is because the link destination is controlled based on an event that is “Click”.

With the mouse operation, the position where the mouse is clicked and that where it is released are almost identical thanks to the physical specification (if they are different, the result becomes the drag operation). However, with the special pen operation, those positions are not always identical and Windows often regards such an operation as dragging. CBdrv ver.1.3 provides an HTML operation-setting item that allows to regard the two positions as the same position. However, care is required in this setting because, if it is set excessively, problems in responses to dragging in operations other than the browser operations as well as delays in start of drawing in general applications will occur.

Q: Is a warning displayed every time the resolution is changed?

A:The warning can be inhibited by disabling the resolution change notification function. In this case, the last adjusted data in the resolution after change is applied automatically.

Q: How is it possible to check normal operation of the driver (hardware)?

A: You can check the coordinates, IP address, computer name, pen button and firm version status in the test display.

Q: How do you temporarily disable CBdrU?

A: Left-click the icon and select “Disable CBdrvU” in the pop-up menu that appears.

Q:How is it possible to identify the resolution of the current output to the plasma display monitor?

A:Open the pop-up menu (by left-clicking on an icon) and check the current resolution value.

45

Image 45
Contents Technical Manual Ver Changes from PDK-50HW2A to PDK-50HW3 Pioneer badge need no longer be removed during installationScan device changes New designFlash pattern of the power indicator has changed Location of the PEN-NORMAL mode selector switch has changedUSB cable clip location Changes made to the pen Pen stand modificationsChanges in the driver Pen stand has been modifiedChanges in service Service Mode has been improvedMiddle button 3-button emulation is supported Contents Specifications SpecificationsSystem plasma display and handwriting device specifications Separate plasma display PDP-504CMX specificationsAccessories Plasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-SHandwriting device PDK-50HW3 Outline Drawing External dimension drawingSide panel Plasma displayPDK-50HW3 as seen from rear PDK-50HW3 center line USB cable exitConfirming Battery Life ¶ External dimension drawingName and Function of Parts & Pin Layout ¶ Name and function of partsInstallation Site Installation SiteInstallation Conditions List showing compatibility of standard metal fittingsSpecial installations Installation of multiple systems Installation precautionsExposure to direct sunlight Ultrasonic wavesUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryConnecting the plasma display to a computer Computer Setup ExamplePrecautions regarding computer setup CheckProcedures for setting the plasma display Adjusting the Plasma DisplayInstalling the Driver Connecting a Scan Device to a ComputerScreen burning Check in Service Mode How to Use Cable ClipCheck in Normal mode Check in PEN mode¶ Alignment of pen tip and cursor position Final Check Installing the CBdrvU Ver .0 Driver Installing and Using SoftwareInstallation procedures Operating environmentUninstall procedures Using the DriverChanges from CBdrv Ver .4 to CBdrvU Ver CBdrvU operationsHot key operations Scan device setup screen Select Calibration dialogScan device off screen Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupTest Mode Test chart displayState display About CBdrvU Disabling CBdrvUExit Disabling CBdrvURotate CBdrvU operationTask tray display Precautions Installing and Using Software Service Mode display Using Driver and Service ModeScreen items Status displayed after pressing SelfTest buttonInstalling and Using Software Readjustment of White Balance Maintenance and CleaningScreen Name Part NumberReplacing the pen tip Pen battery lifeInternal DIP Switch Settings To lock device in the Normal modeTo make waveform observations Hardware-Related Q&A Page Driver Software-Related Q&A Page Troubleshooting Problem Possible SolutionPlasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionLow scan mode ResolutionHigh scan mode Capabilities of the Handwriting Device