Pioneer PDK-50HW3 Name and Function of Parts & Pin Layout, ¶ Name and function of parts

Page 11

1. Specifications

1.4 Name and Function of Parts & Pin Layout

1.4.1 Plasma display monitor (PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S)

For information on the plasma display, refer to “Name and Function of Parts” in the Technical Manual supplied with the

PDP-504CMX.

1.4.2 Handwriting device (PDK-50HW3)

a) Scan device

PEN

NORMAL

IR transmitting filter

Power indicator

(Lights green when ON)

Mode selector switch

Set the mode switch in accordance with whether you will use the special pen or other device to input characters and lines on the screen.

PEN Mode:

In this mode, the special accessory

pen can be used to write on the screen. Using the special pen allows the drawing

Rear side

of more clearly delineated characters and

of unit

lines.

 

 

NORMAL Mode:

 

In this mode, your

 

finger or other

 

object can be used to write on the screen.

 

This mode will produce lower screen

 

definition, however, compared to drawing

 

with the dedicated input pen.

Note:

When the power switch is first turned on, the power indicator will flash orange; while the indicator is flashing, do not touch the screen, since the unit is initializing its internal settings

b) Special pen

Name and function of parts

 

Holes in rear end of pen

 

LED indicator

Tip

 

Cap

Battery cover

 

Large button

 

(corresponds to right

 

mouse button)

Small button

(The function corresponding to middle mouse button can be assigned using the driver software.)

Pen tip

(corresponds to left mouse button)

External dimension drawing

186

If pen operation becomes difficult:

The pen may fail to operate properly if the holes in rear end of pen are blocked. Also, the pen may begin operating erratically when the battery becomes depleted. In this event, change the battery at your earliest opportunity.

Confirming Battery Life:

When the small button is depressed fully, an LED indicator will light. If the indicator fails to light, or lights only dimly, the battery is depleted and should be replaced.

ø18.5

11

Image 11
Contents Technical Manual Ver New design Pioneer badge need no longer be removed during installationChanges from PDK-50HW2A to PDK-50HW3 Scan device changesUSB cable clip location Flash pattern of the power indicator has changedLocation of the PEN-NORMAL mode selector switch has changed Pen stand has been modified Pen stand modificationsChanges made to the pen Changes in the driverMiddle button 3-button emulation is supported Changes in serviceService Mode has been improved Contents Separate plasma display PDP-504CMX specifications SpecificationsSpecifications System plasma display and handwriting device specificationsHandwriting device PDK-50HW3 AccessoriesPlasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Outline Drawing External dimension drawingPDK-50HW3 center line USB cable exit Plasma displaySide panel PDK-50HW3 as seen from rear¶ Name and function of parts ¶ External dimension drawingConfirming Battery Life Name and Function of Parts & Pin LayoutList showing compatibility of standard metal fittings Installation SiteInstallation Site Installation ConditionsSpecial installations Ultrasonic waves Installation precautionsInstallation of multiple systems Exposure to direct sunlightUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryCheck Computer Setup ExampleConnecting the plasma display to a computer Precautions regarding computer setupProcedures for setting the plasma display Adjusting the Plasma DisplayScreen burning Installing the DriverConnecting a Scan Device to a Computer Check in PEN mode How to Use Cable ClipCheck in Service Mode Check in Normal mode¶ Alignment of pen tip and cursor position Final Check Operating environment Installing and Using SoftwareInstalling the CBdrvU Ver .0 Driver Installation proceduresCBdrvU operations Using the DriverUninstall procedures Changes from CBdrv Ver .4 to CBdrvU VerHot key operations Scan device off screen Scan device setup screenSelect Calibration dialog Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupState display Test ModeTest chart display Disabling CBdrvU Disabling CBdrvUAbout CBdrvU ExitTask tray display RotateCBdrvU operation Precautions Installing and Using Software Status displayed after pressing SelfTest button Using Driver and Service ModeService Mode display Screen itemsInstalling and Using Software Name Part Number Maintenance and CleaningReadjustment of White Balance ScreenReplacing the pen tip Pen battery lifeTo make waveform observations Internal DIP Switch SettingsTo lock device in the Normal mode Hardware-Related Q&A Page Driver Software-Related Q&A Page Plasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S TroubleshootingProblem Possible Solution Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionCapabilities of the Handwriting Device ResolutionLow scan mode High scan mode