8. Troubleshooting

 

 

 

8.2 Handwriting Device (PDK-50HW3)

 

 

 

 

Symptom

Cause

Solution

 

 

 

No power

• USB cable is disconnected from

• Connect USB cable to computer

 

computer.

correctly.

 

• Computer power is not turned on.

• Turn on power to computer.

 

 

 

No response when operated.

• USB cable is disconnected.

• Connect USB cable correctly.

 

 

 

USB cable is not recognized by

• USB port may not be operating due

• Consult computer manufacturer for

computer when connected.

to some problem with computer or

BIOS and driver software updates where

 

Windows operating system.

applicable.

 

 

 

Cursor position is far from that

• A screen resolution other than

• Change the driver software settings as

of pen tip on screen.

1280x768 is being used. Or

required.

 

resolution has been changed.

 

 

• The plasma display’s screen display

 

 

size setting has been changed.

 

 

• Driver software is not installed

• Install driver software correctly.

 

properly.

 

 

 

 

Cursor position diverges slightly

• The plasma display’s screen

• Use the plasma display’s calibration

from that of pen tip on screen.

display position has shifted.

mode to adjust the vertical and

 

 

horizontal position.

 

 

 

Cursor position diverges from

• The plasma display’s AUTO SET

• Depending on the image, slight

pen after initial setting.

UP screen position adjustment

divergences can be manually corrected.

 

has been reset.

 

 

• Plasma display’s “MASK CONTROL”

• Set “MASK CONTROL”, “ORBITER” to

 

or “ORBITER” is set to “ON”.

“OFF”.

 

 

 

The special dedicated pen does

• Battery is depleted.

• Check the LED indicator, and if it does

not respond.

 

not light brightly, replace battery.

 

• Insufficient pen tip pressure is

• Press the tip to the screen with

 

being used so that the pen tip

sufficient pressure to turn on the pen tip

 

switch doesn’t turn on.

switch.

 

• The holes in rear end of pen are

• Do not cover the holes in rear end of

 

blocked.

pen.

 

• The pen is being used outside of

• Use only within the proper onscreen

 

its effective range.

usage range.

 

• The unit is receiving ultrasonic

• Do not place any device near the unit

 

influence from other device.

that issues ultrasonic waves.

 

• You are wearing gloves while

• Remove gloves.

 

holding the pen (pen’s ultrasonic

 

 

signals are being absorbed).

 

 

• Driver software is not installed

• Install driver software correctly.

 

properly.

 

 

• Driver software setup is incorrect.

• Check driver setup and reset if appropriate.

 

 

 

Cannot input with finger.

• Mode selector switch on unit’s

• Set switch to “NORMAL”.

 

rear is set to “PEN”.

 

 

 

 

No response to input or can’t

• User touched screen during boot

• Disconnect USB connector and

write in some places.

process (during display of

reconnect.

 

message “Now setting....”)

 

 

• Dirt or other object blocked infrared

• Remove dirt or other obstruction;

 

signal filter, blocking signal.

disconnect and reconnect USB connector.

 

 

 

Computer remains in power

• Main unit will not operate when

• Change power-saving mode as

saving mode even when

computer is in power-saving

appropriate.

operations are performed.

mode.

 

 

 

 

“The device is not connected.

• USB cable is loose or has been

• Connect USB cable securely.

The device is disabled.”

disconnected.

 

message appears.

 

 

 

 

 

49

Image 49
Contents Technical Manual Ver Changes from PDK-50HW2A to PDK-50HW3 Pioneer badge need no longer be removed during installationScan device changes New designLocation of the PEN-NORMAL mode selector switch has changed Flash pattern of the power indicator has changedUSB cable clip location Changes made to the pen Pen stand modificationsChanges in the driver Pen stand has been modifiedService Mode has been improved Changes in serviceMiddle button 3-button emulation is supported Contents Specifications SpecificationsSystem plasma display and handwriting device specifications Separate plasma display PDP-504CMX specificationsPlasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S AccessoriesHandwriting device PDK-50HW3 Outline Drawing External dimension drawingSide panel Plasma displayPDK-50HW3 as seen from rear PDK-50HW3 center line USB cable exitConfirming Battery Life ¶ External dimension drawingName and Function of Parts & Pin Layout ¶ Name and function of partsInstallation Site Installation SiteInstallation Conditions List showing compatibility of standard metal fittingsSpecial installations Installation of multiple systems Installation precautionsExposure to direct sunlight Ultrasonic wavesUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryConnecting the plasma display to a computer Computer Setup ExamplePrecautions regarding computer setup CheckProcedures for setting the plasma display Adjusting the Plasma DisplayConnecting a Scan Device to a Computer Installing the DriverScreen burning Check in Service Mode How to Use Cable ClipCheck in Normal mode Check in PEN mode¶ Alignment of pen tip and cursor position Final Check Installing the CBdrvU Ver .0 Driver Installing and Using SoftwareInstallation procedures Operating environmentUninstall procedures Using the DriverChanges from CBdrv Ver .4 to CBdrvU Ver CBdrvU operationsHot key operations Select Calibration dialog Scan device setup screenScan device off screen Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupTest chart display Test ModeState display About CBdrvU Disabling CBdrvUExit Disabling CBdrvUCBdrvU operation RotateTask tray display Precautions Installing and Using Software Service Mode display Using Driver and Service ModeScreen items Status displayed after pressing SelfTest buttonInstalling and Using Software Readjustment of White Balance Maintenance and CleaningScreen Name Part NumberReplacing the pen tip Pen battery lifeTo lock device in the Normal mode Internal DIP Switch SettingsTo make waveform observations Hardware-Related Q&A Page Driver Software-Related Q&A Page Problem Possible Solution TroubleshootingPlasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionLow scan mode ResolutionHigh scan mode Capabilities of the Handwriting Device