TROUBLESHOOTING & REPAIR

F-11

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

TIG WELDING PROBLEMS

 

 

High frequency "spark" is present at

1.

The torch may be faulty. Check

1. This may be a welding procedure

tungsten electrode, but operator is

 

or replace.

problem.

 

unable to establish a welding arc.

 

 

 

 

Machine has normal open circuit

2.

The current control may be set

Contact The Lincoln Electric Service

voltage. Refer to Technical

 

 

too low.

Department 1-888-935-3877.

 

Specifications in the Installation

 

 

 

 

Chapter.

 

3.

The tungsten electrode may be

 

 

 

 

 

contaminated. Replace or sharp-

 

 

 

 

 

en.

 

 

 

 

4. The electrode may be too large

 

 

 

 

 

for the process.

 

 

 

 

5.

If a helium blend is being used

 

 

 

 

 

as a shielding gas, then reduce

 

 

 

 

 

the percentage of helium.

 

 

 

 

6.

Check the welding cables for

 

 

 

 

 

loose or faulty connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION