TOC

TOC

F-18

TROUBLESHOOTING & REPAIR

F-18

T1 TRANSFORMER TEST (continued)

TEST PROCEDURE

1.Remove main supply power to the machine.

2.Using the 3/8” nutdriver remove the case wrap-around cover.

3.Locate plugs J3 and J4 on the control board. See Figure F.2.

4.Carefully apply the correct input power making certain the reconnect configuration at the input switch is correct for the input voltage applied. Turn the TIG 185 ON.

5.Using the voltmeter carefully test for the correct transformer secondary voltages per Table F.1.

Section TOC

Master TOC

FIGURE F.2 - Plugs J3 & J4 on Control Board

Return to

Return to Master TOC

PRECISION TIG 185 CONTROL BOARD

J2

J3

J4

PIN 7 (LEAD #209) PIN 8 (LEAD #210)

PIN 3 (LEAD #204) PIN 4 (LEAD #201)

PIN 3 (LEAD #232) PIN 2 (LEAD #260)

Return to Master TOC

PRECISION TIG 185

Page 56
Image 56
Lincoln Electric SVM169-A service manual T1 Transformer Test, Test Procedure