TOC

TOC

F-19

TROUBLESHOOTING & REPAIR

F-19

T1 TRANSFORMER TEST (continued)

6.If all of the secondary voltages are correct the T1 transformer is func- tioning properly.

A.If all of the secondary voltages are missing or incorrect make certain that the correct input volt- age is being applied to the correct primary leads. See Table F.1.

B.If the correct input voltage is being applied to the primary leads and any or all of the secondary voltages are incorrect the T1

transformer may faulty.

See

Main Transformer and Output

Choke Removal and Replacement. Also check the leads for broken or loose connec- tions between plugs J3, J4 and the T1 transformer.

7. Replace case wrap-around cover.

Return to

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

TABLE F.1 T1 TRANSFORMER VOLTAGE

TEST POINTS

ACCEPTABLE VOLTAGES

 

 

SECONDARY WINDINGS

SECONDARY VOLTAGES

 

 

PLUG J3 PIN 8 (LEAD #210)

 

TO

18VAC

PLUG J3 PIN 7 (LEAD #209)

 

 

 

PLUG J3 PIN 4 (LEAD #201)

 

TO

18VAC

PLUG J3 PIN 3 (LEAD #204)

 

 

 

PLUG J4 PIN 2 (LEAD #260)

CHECK DURING FIRST 5 SECONDS OF POWER UP

TO

115VAC

PLUG J4 PIN 3 (LEAD #232)

 

 

 

X1 TO X2

80 VAC

 

 

PRIMARY WINDINGS

PRIMARY VOLTAGES

 

 

H1 TO H2

208VAC

 

 

H1 TO H3

230VAC

 

 

NOTE: If the input voltages vary the secondary voltages will vary accordingly.

PRECISION TIG 185

Page 57
Image 57
Lincoln Electric SVM169-A service manual Return to Section Section TOC, Primary Windings Primary Voltages