TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

AC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

____________________________________________________________________

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

10 V

MACHINE LOADED TO 180 AMPS AT 16VDC.

This is the typical AC output voltage wave- form generated from a properly operating machine. Note that each vertical division represents 10 volts and that each horizontal division represents 2 milliseconds in time. The machine was loaded with a resistance grid bank. The grid load meters read 180 amps and 16VDC

Note: Scope probes connected at machine

output terminals: (+) probe to electrode, (–) probe to work.

0 V

2 ms

SCOPE SETTINGS

Volts/Div

10 V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 