Return to Section TOC

Return to Section TOC

Section TOC

Return to Master TOC

Return to Master TOC

Master TOC

F-27

TROUBLESHOOTING & REPAIR

F-27

ACTIVE SCR TEST (continued)

 

SCR2 CATHODE

SCR1 ANODE

SCR3 CATHODE

 

 

SCR4 ANODE

SCR1 CATHODE/SCR2 ANODE

SCR3 ANODE/SCR4 CATHODE

PLUG J2

3

 

4

 

 

 

 

 

 

SCR3

 

SCR4

 

 

 

 

 

 

 

 

 

 

 

SCR1

 

SCR2

 

 

 

 

 

 

1

2

 

S24018-4 (INSERTION SIDE)

SCR GATE LEADS/TEST POINTS

FIGURE F.6 SCR GATE LOCATIONS

Return to

Return to Master TOC

6.Connect SCR into the test circuit as shown (A) lead to anode (C) lead to cathode and (G) lead to the gate.

7.Close switch SW-1 (switch SW-2 should open), voltmeter should read zero. If the voltmeter reads higher than zero the SCR is shorted.

8.With switch SW-1 closed, close switch SW-2 for two seconds and release. The voltmeter should read 3 to 6 volts before and after switch SW- 2 is released. If the voltmeter does not read, or reads only while SW-2 is depressed, the SCR or battery is defective (repeat Battery Test Procedure above).

9.Open switch SW-1, disconnect the gate lead (G) and reverse the (A) and

(C)leads on the SCR. Close switch SW-1. The voltmeter should read zero. If the voltage is higher than zero, the SCR is shorted.

10.Replace SCR Bridge Assembly if any SCRs do not pass the test in Step #3. See SCR Bridge

Assembly Removal and Replacement.

11.Replace plug J2 into the control board.

12.Replace the case wrap-around cover.

PRECISION TIG 185

Page 65
Image 65
Lincoln Electric SVM169-A service manual Figure F.6 SCR Gate Locations