TROUBLESHOOTING & REPAIR

F-8

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

TIG MODE PROBLEMS

 

 

 

Machine output is intermittently lost.

1.

The problem may be caused by

1.

Check for loose or faulty connec-

Gas flow and high frequency are

 

high frequency interference.

 

tion on the leads between the

 

also interrupted.

 

 

Make sure that the machine is

 

remote receptacle and plug J5

 

 

 

 

grounded properly according to

 

on the control board. See wiring

 

 

 

the installation instructions. If

 

diagram.

 

 

 

 

there are other high frequency

 

 

 

 

 

 

sources in the area, make certain

2. Check the plugs on the control

 

 

 

that they are grounded properly.

 

board for loose connections.

 

 

 

2.

Make sure the Amptrol is operat-

3.

The control board may be faulty.

 

 

 

ing properly.

 

 

 

 

 

3. Check to make sure that the

 

 

 

 

 

 

input voltage is correct for the

 

 

 

 

 

 

machine reconnect configuration.

 

 

 

 

 

 

Refer to Reconnect Procedure

 

 

 

 

 

 

in the Installation section of this

 

 

 

 

 

 

manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION