Lincoln Electric SVM169-A Normal Open Circuit Voltage Waveform, AC TIG Mode, Scope Settings

Models: SVM169-A

1 104
Download 104 pages 53.72 Kb
Page 67
Image 67

Return to Master TOC

F-29

TROUBLESHOOTING & REPAIR

F-29

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

AC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

____________________________________________________________________

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

50 V

This is the typical AC output voltage wave- form generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 2 milliseconds in time.

Note: Scope probes connected at machine

output terminals: (+) probe to electrode, (–) probe to work.

0 V

2 ms

SCOPE SETTINGS

Volts/Div

50 V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 