TROUBLESHOOTING & REPAIR | |||||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | ||
|
| detailed in the beginning of this manual. | |||
|
|
|
|
|
|
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
|
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
Machine regularly over heats - ther- | Machine regularly over heats - ther- | 1. | The thermostat(s) may be faulty. | ||
mostat opens. Yellow light on front | mostat opens. Yellow light on front |
| Check or replace. |
| |
panel glows. The fan runs but the | panel glows. The fan runs but the |
|
|
| |
machine has no output. |
| machine has no output. | 2. | The control board may be faulty. |
The machine does not have output | The machine does not have output 1. | Check the Stick/TIG switch(S3) |
in the Stick mode. The machine | in the Stick mode. The machine | and associated leads. See |
operates correctly in the TIG mode. | operates correctly in the TIG mode. | wiring diagram. |
| 2. | The control board may be faulty. |
CAUTION