Lincoln Electric SVM169-A High Frequency Circuit Disable Procedure, Test Description

Models: SVM169-A

1 104
Download 104 pages 53.72 Kb
Page 53
Image 53

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-15

TROUBLESHOOTING & REPAIR

F-15

HIGH FREQUENCY CIRCUIT DISABLE PROCEDURE

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test / repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This procedure will disable the high frequency circuit. The technician will then be able to take voltage measurements without the possibility of high frequency damage to his test equipment.

MATERIALS NEEDED

3/8” Nutdriver

5/64” Allen type wrench

.020” feeler gauge

WARNING

HIGH VOLTAGE IS STILL PRESENT IN THE HIGH FREQUENCY CIRCUIT.

----------------------------------------------------------------------------------------------------------------------------

PRECISION TIG 185

Page 53
Image 53
Lincoln Electric SVM169-A service manual High Frequency Circuit Disable Procedure, Test Description