Return to Section TOC

Return to Master TOC

A-2

INSTALLATION

A-2

 

TECHNICAL SPECIFICATIONS - PRECISION TIG 185 (K2345-1AND K2347-1,-2)

 

 

 

 

 

 

 

INPUT - SINGLE PHASE ONLY

 

 

 

 

 

 

 

Standard Voltage

 

Input Current at Rated Output

 

 

208/230/1/60

 

35A / 32A Effective

 

 

 

 

and 70A / 64A Maximum

 

 

 

 

 

 

 

 

OUTPUT

RANGE

 

Return to Section TOC

Return to Master TOC

Output Current

Range

7-185 Amps (AC)

5-185 Amps (DC)

Duty Cycle

GTAW 15% Duty Cycle 100% Duty Cycle

SMAW 15% Duty Cycle 100% Duty Cycle

Maximum Open

Circuit Voltage

(STICK AND TIG)

AC OCV: 75

DC OCV: 59

RATED OUTPUT

Amps

185A AC/DC

90A AC/DC (BAL)

70A AC (AUTO-BAL)

185A AC/DC125

90A AC/DC

Type of Output

CC(Constant Current) AC/DC

Volts at Rated Amperes

15.2V AC/DC

14.1V AC/DC

13.8V AC/DC

27.4V AC/DC

23.6V AC/DC

Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle) (Example; 110A@60% for AC/DC Stick and Balance TIG)

Using standard #8-3 input cable for protected(1) input supply

Return to Section TOC

TOC

Return to Master TOC

TOC

 

100%

 

 

 

 

 

 

 

CYCLE

90%

 

 

 

 

 

 

 

80%

 

 

 

 

 

 

 

70%

 

 

 

 

 

 

 

DUTY

 

 

 

 

 

 

 

60%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%

50%

 

 

 

 

 

 

 

OUTPUT

40%

 

 

 

 

 

 

 

30%

 

 

 

 

 

 

 

20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10%

 

 

 

 

 

 

 

 

0%

 

 

 

 

 

 

 

 

50

70

90

110

130

150

170

190

OUTPUT AMPS

208/230v Model: AC/DC Stick & DC TIG

(AC TIG with #6-3 input cable)

460/575v Model: AC/DC Stick & AC/DC TIG

380/415v Model: AC/DC Stick & DC/AC Auto-Bal.TIG

208/230v Model: AC TIG using 230v input

380/415v Model: AC TIG (Max. Penetration)

208/230v Model: AC TIG using 208v input

(1)Wiring and protection based on the 2002 U.S. National Electric Code: Use a Super Lag type fuse or circuit breaker with a delay in tripping action.

Models with NEMA 6-50P plug may be used with a 50 amp protected 6-50R receptacle, or with a maximum 70 amp protected 6-50R receptacle if dedicated for the welder.

PRECISION TIG 185

Page 8
Image 8
Lincoln Electric SVM169-A service manual Installation, Input Single Phase only