Lincoln Electric SVM169-A service manual Troubleshooting and Repair

Models: SVM169-A

1 104
Download 104 pages 53.72 Kb
Page 77
Image 77

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-39

TROUBLESHOOTING AND REPAIR

F-39

 

 

SCR BRIDGE ASSEMBLY

REMOVAL AND REPLACEMENT PROCEDURE

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test / repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This procedure will aid the technician in the removal and replacement of the SCR assembly

MATERIALS NEEDED

5/16” nutdriver

3/8” nutdriver

Needle nose pliers

7/16” Wrench

3/8” Wrench

Slot head screwdriver

Dow Corning 340 Heat Sink compound