Pioneer PDK-50HW3 specifications Hardware-Related Q&A

Page 43

7. Q & A

7.1 Hardware-Related Q&A

Q:Which is the touch panel system?

A:It is based on the IR scan system.

Q: Which is the advantage of the IR scan system?

A: It is the capability of direct drawing on the screen. This does not deteriorate the picture quality nor cause parallax.

Q: Are there any consumables?

A: The pen tip and the battery are consumables. Two extra pen tips are supplied. The pen tip is available as a service part.

Q: How long is the service life of infrared LEDs?

A:10,000 hours or more in a normal operating environment. This refers to hours of continuous use. Since normal use is not continuous, service life under normal conditions should be two or three times 10,000 hours.

Q: How long is the service life of the pen battery?

A:20 hours of continuous use when an alkaline battery is used.

One screenfull of characters that are 6 cm wide and 6 cm high would contain 120 characters (when two thirds of the screen is used for writing). It takes an average of 1 second to write a 6 cm wide and 6 cm high character, one screenfull takes 2 minutes to write. Assuming that 5 pages are written every hour of class or business meeting, the pen is used 10 minutes every hour. If there are 6 hours of classes or business meetings per day, the battery is used up to 20 hours, which would correspond to one working month (20 days). The pen battery should therefore last a month.

Q: Does the system deteriorates by aging?

A:Basically, it does not deteriorate over time. However, malfunctions may occur if the light intensity drops considerably due to excessive deposition of cigarette tars or dust.

Q: Which are the effects of dirt on the performance?

A: Dirt on the IR filter should be removed because it deteriorates the light intensity.

Q: What would happen if the light sensor elements break down?

A:To ensure normal operation, malfunctioning sensors are detected and removed from processing at the time the power is turned on. However, as the resolution may drop in the areas where malfunctioning sensors are detected, detailed drawing is not possible in those areas.

Q: Which is the detection distance from the panel surface?

A:The reaction to a light-shielding object is variable depending on the thickness and positioning of the object, but it is usually detected at about 5 mm from the panel surface.

Q: Is it possible to write letters using an object other than the special pen?

A:Yes, it is possible. In addition to the PEN mode, a mode is provided to allow writing by anything including a finger (NORMAL mode). The factory-setting mode is the NORMAL mode.

Q:Writing on the screen using a finger will soil it. Can a glass cleaner or similar detergent be used to clean the screen?

A:Basically, such detergents should not be used. Use the supplied wiping cloth to clean the plasma display. If the screen is heavily soiled and a detergent is required, use a soft cloth slightly dampened in a solution of a neutral detergent and water. Wring out the cloth thoroughly, wipe the screen clean and then wipe with a dry cloth.

Q: Is the screen scratch resistant?

A: No, bringing a propelling pencil or other sharp pointed object in contact with the screen will scratch it.

43

Image 43
Contents Technical Manual Ver New design Pioneer badge need no longer be removed during installationChanges from PDK-50HW2A to PDK-50HW3 Scan device changesLocation of the PEN-NORMAL mode selector switch has changed Flash pattern of the power indicator has changedUSB cable clip location Pen stand has been modified Pen stand modificationsChanges made to the pen Changes in the driverService Mode has been improved Changes in serviceMiddle button 3-button emulation is supported Contents Separate plasma display PDP-504CMX specifications SpecificationsSpecifications System plasma display and handwriting device specificationsPlasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S AccessoriesHandwriting device PDK-50HW3 Outline Drawing External dimension drawingPDK-50HW3 center line USB cable exit Plasma displaySide panel PDK-50HW3 as seen from rear¶ Name and function of parts ¶ External dimension drawingConfirming Battery Life Name and Function of Parts & Pin LayoutList showing compatibility of standard metal fittings Installation SiteInstallation Site Installation ConditionsSpecial installations Ultrasonic waves Installation precautionsInstallation of multiple systems Exposure to direct sunlightUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryCheck Computer Setup ExampleConnecting the plasma display to a computer Precautions regarding computer setupProcedures for setting the plasma display Adjusting the Plasma DisplayConnecting a Scan Device to a Computer Installing the DriverScreen burning Check in PEN mode How to Use Cable ClipCheck in Service Mode Check in Normal mode¶ Alignment of pen tip and cursor position Final Check Operating environment Installing and Using SoftwareInstalling the CBdrvU Ver .0 Driver Installation proceduresCBdrvU operations Using the DriverUninstall procedures Changes from CBdrv Ver .4 to CBdrvU VerHot key operations Select Calibration dialog Scan device setup screenScan device off screen Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupTest chart display Test ModeState display Disabling CBdrvU Disabling CBdrvUAbout CBdrvU ExitCBdrvU operation RotateTask tray display Precautions Installing and Using Software Status displayed after pressing SelfTest button Using Driver and Service ModeService Mode display Screen itemsInstalling and Using Software Name Part Number Maintenance and CleaningReadjustment of White Balance ScreenReplacing the pen tip Pen battery lifeTo lock device in the Normal mode Internal DIP Switch SettingsTo make waveform observations Hardware-Related Q&A Page Driver Software-Related Q&A Page Problem Possible Solution TroubleshootingPlasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionCapabilities of the Handwriting Device ResolutionLow scan mode High scan mode