Pioneer PDK-50HW3 specifications Test Mode, State display, Test chart display

Page 33

4. Installing and Using Software

4.2.4 Test Mode

This is a service mode. Click “Test Mode” under “Hardware Information” in the CBdrvU task tray to open the screen shown below.

a) State display

This screen shows results of hardware checks and the state of the driver and the operating system (Windows).

[Function overview]

 

Driver

 

Software Ver:

Indicate the version of the CBdrvU setup program

Pen Button (small):

Indicate the setting of the small pen button in the Property screen

Service Ver:

Indicate the version of the USB filter driver

Firmware Ver:

Indicate the version of the scan device firmware

System

Buttons:: Correctly recognized

: Not correctly recognized (during 3-button mouse emulation)

L:

Left mouse button

R:

Right mouse button

M:

Middle mouse button

Mouse pos:

Indicate mouse coordinates recognized by Windows

Angle:

Indicate currently set rotate angle

IP Address:

Indicate IP address of the connected PC

Computer Name:

Indicate the name of the connected PC

Service Mode:

Indicate scan device service information and DIP switch information.

 

This mode is not required during normal operation.

Test chart display:

Adjust plasma display. This mode is not required for normal operation.

b) Test chart display

This is a service mode. Use it to adjust plasma display settings.

Notes:

The plasma display need not be adjusted if it has already been set up.

Use the supplied remote control to adjust the plasma display. For details, refer to the Operating Instructions.

Press the [Esc] key or use the pen to click on the screen.

33

Image 33
Contents Technical Manual Ver Changes from PDK-50HW2A to PDK-50HW3 Pioneer badge need no longer be removed during installationScan device changes New designFlash pattern of the power indicator has changed Location of the PEN-NORMAL mode selector switch has changedUSB cable clip location Changes made to the pen Pen stand modificationsChanges in the driver Pen stand has been modifiedChanges in service Service Mode has been improvedMiddle button 3-button emulation is supported Contents Specifications SpecificationsSystem plasma display and handwriting device specifications Separate plasma display PDP-504CMX specificationsAccessories Plasma display monitor PDP-504CMX/PDP-50MXE1/PDP-50MXE1-SHandwriting device PDK-50HW3 Outline Drawing External dimension drawingSide panel Plasma displayPDK-50HW3 as seen from rear PDK-50HW3 center line USB cable exitConfirming Battery Life ¶ External dimension drawingName and Function of Parts & Pin Layout ¶ Name and function of partsInstallation Site Installation SiteInstallation Conditions List showing compatibility of standard metal fittingsSpecial installations Installation of multiple systems Installation precautionsExposure to direct sunlight Ultrasonic wavesUnpacking Installation ProceduresTransportation precautions Installing the handwriting device PDK-50HW3 Assembly and ConnectionsBattery cover Changing the pen batteryConnecting the plasma display to a computer Computer Setup ExamplePrecautions regarding computer setup CheckProcedures for setting the plasma display Adjusting the Plasma DisplayInstalling the Driver Connecting a Scan Device to a ComputerScreen burning Check in Service Mode How to Use Cable ClipCheck in Normal mode Check in PEN mode¶ Alignment of pen tip and cursor position Final Check Installing the CBdrvU Ver .0 Driver Installing and Using SoftwareInstallation procedures Operating environmentUninstall procedures Using the DriverChanges from CBdrv Ver .4 to CBdrvU Ver CBdrvU operationsHot key operations Scan device setup screen Select Calibration dialogScan device off screen Calibration Detail-1 OK buttonCalibration Detail-2 Easy SettingDouble-click area Property screenDouble-click speed Other setupTest Mode Test chart displayState display About CBdrvU Disabling CBdrvUExit Disabling CBdrvURotate CBdrvU operationTask tray display Precautions Installing and Using Software Service Mode display Using Driver and Service ModeScreen items Status displayed after pressing SelfTest buttonInstalling and Using Software Readjustment of White Balance Maintenance and CleaningScreen Name Part NumberReplacing the pen tip Pen battery lifeInternal DIP Switch Settings To lock device in the Normal modeTo make waveform observations Hardware-Related Q&A Page Driver Software-Related Q&A Page Troubleshooting Problem Possible SolutionPlasma Display PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S Error messege Remedy TroubleshootingHandwriting Device PDK-50HW3 Symptom Cause SolutionLow scan mode ResolutionHigh scan mode Capabilities of the Handwriting Device