Panasonic WJ-HD500B Button Locked Function, To release this function, follow the procedure below

Page 101

BUTTON LOCKED FUNCTION

The system setup and operations can be password protect- ed to prevent malfunction of the system due to accidental erasure of data, alteration of settings or erroneous opera- tions by unauthorized persons.

There are two passwords shown below corresponding to a limit of operations.

ALL: Both normal operations and setup operations are allowed.

OPERATION: Normal operations are allowed.

Note: The button locked function is disabled even the LOCK button is pressed while the status shown below.

Being played back the images.

The setup menu is displayed on the monitor screen.

The recorded list or thumbnail is displayed on the moni- tor screen.

The described below are procedure to lock and release locked.

1.Press the LOCK button for two seconds or more to apply the button locked function.

“KEY LOCK DONE!” display will appear on the Multiscreen Monitor for about two seconds.

The indicator in the button lights to indicate the button locked mode is selected.

LOCK

To release this function, follow the procedure below.

2.Press the LOCK button for two seconds or more to dis- play the password inquiry window shown below on the Multiscreen Monitor.

LOCK

PASSWORDB–––––

Note: The window will be closed automatically if no input is made for about 30 seconds.

3.Select the ALL or OPERATION password (5-digit) by pressing the Numeric buttons (1 - 10).

To select “0” for numeric input, press the numeric 10 button.

Entering input will automatically verify a password.

If the password is not correct, “PASSWORD ERROR!” is displayed on the monitor screen and returns to the step 2 display.

To try to enter password again, repeat procedures 3.

To quit entering password, press the SETUP/ESC but- ton.

4.If the password is correct, “KEY UNLOCKED!” is dis- played on the monitor screen for about two seconds and returns to the normal view.

The indicator in the LOCK button is off.

Note: It will be locked automatically, if no operation takes place within five minutes.

To enter the ALL password after entering OPERATION password on step 3, follow the procedure below.

1.Press the LOCK button for two seconds or more to lock the system.

2.Repeat the procedure from the step 2 by pressing the LOCK button.

101

Image 101
Contents Operating Instructions Lightning flash with arrowhead symbol Contents Preface FeaturesReliable recording of events Easy image searchPrecautions Front View @8Setup/Escape Button SETUP/ESC @4Alarm Search Button Alarm Search1Numeric Buttons 1 2Set Button SET#1Hard Disk Drive Indicator HDD @9Direction Buttons CDA B #0Full Indicator Full$1Multiscreen Output Connector Multiscreen OUT $22Spot Output Connector Spot OUT$9Mode Selector Mode $7Alarm Port Alarm2Gen-lock Output Connector GEN-LOCK OUT 8Power Switch Power ON/OFF1Lock Button Lock WV-CU50 Remote Controller2Monitor Selection Button 3Multiscreen Selection Button1Link Indicator Link 9Alarm Search Button Alarm SearchBlinking Pause mode 0JogDial 6Electronic Zoom Button EL-ZOOMInstalling the Optional Hard Disk InstallationInstalling the Optional Network Board Installing the Optional Motion Detector Board Mounting into the Rack Basic System ConnectionsSystem Expansion Shown below are examples of system connectionsConnection with the Monitors Connection with the Remote ControllerConnection with the Camera Sites Alarm Alarm Port ConnectionControl Port Connection Connection with Control output Connection with the Uninterrupted Power Supply UPSConnection with the Extension Units Switch SettingScsi Connection ModeConnection with the DVD Extension Unit without HDD Switch SettingsConnection with the DVD Extension Unit Copy WJ-HDE510B EXT Connection with the DVD Extension Unit with HDDConnection to PS Data Compatible Equipment Mode Selector Setting10/100BASE-T Port Connection Serial Port ConnectionPage Preparations Power UP Procedure Formatting the Hard Disk 1DISK Format Formatting the DVD-RAM Disk Mirroring Function To deactivate the mirror function Disk Remove Spot and Multiscreen Monitor Monitors and DisplaysStatus Display Time DisplaySystem Status Display Format Error orGroup Display Electronic Zoom DisplayHard Disk Timer RecorderManual Recorder Emergency RecorderDynamic Recording is set to OFF Time Lapse RecordingMulti Shot Recording Dynamic Recording is set to ALM-ONLY One Shot RecordingPage Setup Procedures Displaying the Setup Menu Setup MenuDisplay Setup Communication Setup Programming Menu SetupSetup Timer Setting Recording Setup Timer Setting Recording Quality Setup Recording SetupVideo Pixels Resolution Color Mode SettingGroup Title Setup Group SetupCamera Assignment SpacePlayback Mode Setup Thumbnail Display SetupShuttle Speed Setup Recording of the Title Display→ Manual with Audio → Manual Without Audio → Hard Disk End SetupManual Recording Mode Setting Event Recording Manual Recording Program Timer Alarm Active Mode Manual RecordingSpecial Day Timer Time Lapse Recording Internal Timer External Program TimerEvent Recording Alarm Active ModeMulti Shot Recording Internal Timer One Shot Recording Internal Timer Emergency Recording Time Lapse Recording Sequence Setup Multiscreen Monitor Multiplexer SetupLive Sequence Pattern Setting Live SequenceSequence Timing Setting Quad Shift SettingQuad Pattern Setup Group Multi Sequence Setting Sequence Setup Spot MonitorAuto Skip Setting Live Sequence Pattern SettingSequence Timing Setting Power on Setting Multiscreen MonitorPower on Setting Spot Monitor Secret View Setting Alarm Port Setting Alarm SetupAlarm Auto Reset Setting Alarm Output SettingVideo Motion Detector Setting Alarm Buzzer SettingVideo Loss Alarm Setting Alarm Mode on the Spot Monitor Alarm Mode on the Multiscreen MonitorCamera Title Setup Display SetupDisplay Setting Multiscreen Monitor Clock DisplayAlarm Display Setting Title Display Setting Spot MonitorTitle Display Status DisplayTitle Display Position Setting Clock and Status Display Position SettingPS Data Setup Communication SetupUnit Address Setting Baud RateInput Camera Number Setup Alarm DataParity Check Stop BitRS-232C Setup Network Setup Clock Setup System SetupTime Adjustment Setting SET TimeBuzzer Setting Password Lock SettingUser Defined Setting Auto Button Locked SettingDisk Information Disk Space IndicatorDisk Management System Information Error ReportDVD Format DVD Drive SetupAlarm Recording Backup Disk Space Display Emergency Recording BackupDVD Disk End Setup Page Operating Procedures Controlling the Spot Monitor Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveZooming Single Spot Live Controlling the Multiscreen MonitorSelecting the Multiscreen Monitor Group Single Sequence Live All Input Display with Quad Shift Off Multiscreen Spot LiveMultiscreen Select All Input Display with Quad Shift On Group Display Multi Sequence LiveGroup Multi Sequence Multi Group setting Quad settingAlarm Operation Alarm Control FunctionAlarm Input Alarm Suspension Alarm ResetManual Reset Auto ResetPower-on Time Lapse Recording Internal Timer RecordingRecording Manual RecordingSet to ALM-ONLY Alarm RecordingAlarm Recording for Manual and Power-on Recording Time Lapse Recording Alarm Recording for Internal Timer ModesSet to ALM-MULTI Emergency Recording Basic Playback PlaybackStop Forward or Backward searchSearch Record Function Alarm jump searchJump search Record ListTime & Date Search Alarm Log SearchDisplay Zooming Single Spot Playback Display on the MonitorSingle and Multiscreen Spot Playback REC Preview Displaying Camera and Playback ImageJogDial Backup FunctionALM-VMD2 Total 931RECORD Auto Erase Function Data Erase FunctionManual Erase Function Lock To release this function, follow the procedure belowButton Locked Function Playback of Backup Data Standard Accessory SpecificationsGeneral Input and OutputN1102-0 V8QA6084AN