Panasonic WJ-HD500B Communication Setup, PS Data Setup, Unit Address Setting, Baud Rate, Data Bit

Page 68

COMMUNICATION SETUP

The procedures described below let you set the parame- ters for the Disk Recorder to communicate with external devices.

1.Move the cursor to COMMUNICATION SETUP in the WJ-HD500 SETUP menu by pressing the C or D but- ton, then press the SET button.

The COMMUNICATION SETUP menu shown below appears on the monitor screen.

8 COMMUNICATION SETUP

PS•Data SETUP

RS232C SETUP

NETWORK SETUP

 

DHCP

OFF

IP ADDRESS

192.168.000.010

NETMASK

255.255.255.000

GATEWAY

192.168.000.001

2.Select an item or item parameter in the menu by press- ing the D or C button.

3.To return to the previous setup menu, press the SETUP/ESC button.

Unit Address Setting

This item lets you set the unit address of the Disk Recorder in the system for RS-485 communication.

1.Move the cursor to the UNIT ADDRESS parameter by pressing the D or C button.

2.Select the unit address number to be used for RS-485 communication by pressing the + or - button.

Select a parameter value between 001 and 099.

The factory default setting is 001.

2.Select an item or item parameter in the menu by press- ing the D or C button.

3.To return to the previous WJ-HD500 SETUP menu, press the SETUP/ESC button.

PS Data Setup

These items let you set the parameters for communication between the System Controllers and the Disk Recorders when the system is controlled with the PS Data mode (Panasonic Security Data).

1.Move the cursor to PS Data SETUP in the COMMUNI- CATION SETUP menu by pressing the C or D button, then press the SET button.

The PS Data SETUP menu shown below appears on the monitor screen.

8-1 PS•Data SETUP

UNIT ADDRESS

001

BAUD RATE

9600

DATA BIT

8

PARITY CHECK

NONE

STOP BIT

1

WAIT TIME

OFF

ALARM DATA

1S

CAMERA NUMBER SETUP

Baud Rate

This item lets you set the transmission speed for RS-485 communication.

1.Move the cursor to the BAUD RATE parameter by pressing the D or C button.

2.Select the desired transmission speed shown below by pressing the + or - button.

2 400 4 800 9 600 19 200 38 400

The factory default setting is 9 600 bps.

Data Bit

This item lets you set the number of data bits for RS-485 communication.

The factory default setting is 8 bits and fixed.

68

Image 68
Contents Operating Instructions Lightning flash with arrowhead symbol Contents Features PrefaceReliable recording of events Easy image searchPrecautions Front View @4Alarm Search Button Alarm Search @8Setup/Escape Button SETUP/ESC1Numeric Buttons 1 2Set Button SET@9Direction Buttons CDA B #0Full Indicator Full #1Hard Disk Drive Indicator HDD$1Multiscreen Output Connector Multiscreen OUT $22Spot Output Connector Spot OUT$7Alarm Port Alarm $9Mode Selector Mode2Gen-lock Output Connector GEN-LOCK OUT 8Power Switch Power ON/OFFWV-CU50 Remote Controller 1Lock Button Lock2Monitor Selection Button 3Multiscreen Selection Button9Alarm Search Button Alarm Search 1Link Indicator LinkBlinking Pause mode 0JogDial 6Electronic Zoom Button EL-ZOOMInstallation Installing the Optional Hard DiskInstalling the Optional Network Board Installing the Optional Motion Detector Board Mounting into the Rack Connections Basic SystemSystem Expansion Shown below are examples of system connectionsConnection with the Monitors Connection with the Remote ControllerConnection with the Camera Sites Alarm Port Connection AlarmControl Port Connection Connection with the Uninterrupted Power Supply UPS Connection with Control outputSwitch Setting Connection with the Extension UnitsScsi Connection ModeConnection with the DVD Extension Unit without HDD Switch SettingsConnection with the DVD Extension Unit Connection with the DVD Extension Unit with HDD Copy WJ-HDE510B EXTMode Selector Setting Connection to PS Data Compatible EquipmentSerial Port Connection 10/100BASE-T Port ConnectionPage Preparations Power UP Procedure Formatting the Hard Disk 1DISK Format Formatting the DVD-RAM Disk Mirroring Function To deactivate the mirror function Disk Remove Monitors and Displays Spot and Multiscreen MonitorStatus Display Time DisplayFormat Error or System Status DisplayGroup Display Electronic Zoom DisplayTimer Recorder Hard DiskManual Recorder Emergency RecorderDynamic Recording is set to OFF Time Lapse RecordingMulti Shot Recording One Shot Recording Dynamic Recording is set to ALM-ONLYPage Setup Procedures Setup Menu Displaying the Setup MenuDisplay Setup Communication Setup Programming Menu SetupSetup Timer Setting Recording Setup Timer Setting Recording Setup Recording Quality SetupVideo Pixels Resolution Color Mode SettingGroup Setup Group Title SetupCamera Assignment SpaceThumbnail Display Setup Playback Mode SetupShuttle Speed Setup Recording of the Title Display→ Manual with Audio → Manual Without Audio → Hard Disk End SetupManual Recording Mode Setting Event Recording Manual Recording Alarm Active Mode Manual Recording Program TimerSpecial Day Timer External Program Timer Time Lapse Recording Internal TimerAlarm Active Mode Event RecordingMulti Shot Recording Internal Timer One Shot Recording Internal Timer Emergency Recording Time Lapse Recording Multiplexer Setup Sequence Setup Multiscreen MonitorLive Sequence Pattern Setting Live SequenceSequence Timing Setting Quad Shift SettingQuad Pattern Setup Sequence Setup Spot Monitor Group Multi Sequence SettingAuto Skip Setting Live Sequence Pattern SettingSequence Timing Setting Power on Setting Multiscreen MonitorPower on Setting Spot Monitor Secret View Setting Alarm Setup Alarm Port SettingAlarm Auto Reset Setting Alarm Output SettingVideo Motion Detector Setting Alarm Buzzer SettingVideo Loss Alarm Setting Alarm Mode on the Multiscreen Monitor Alarm Mode on the Spot MonitorDisplay Setup Camera Title SetupDisplay Setting Multiscreen Monitor Clock DisplayTitle Display Setting Spot Monitor Alarm Display SettingTitle Display Status DisplayClock and Status Display Position Setting Title Display Position SettingCommunication Setup PS Data SetupUnit Address Setting Baud RateAlarm Data Input Camera Number SetupParity Check Stop BitRS-232C Setup Network Setup System Setup Clock SetupTime Adjustment Setting SET TimePassword Lock Setting Buzzer SettingUser Defined Setting Auto Button Locked SettingDisk Information Disk Space IndicatorDisk Management Error Report System InformationDVD Format DVD Drive SetupAlarm Recording Backup Disk Space Display Emergency Recording BackupDVD Disk End Setup Page Operating Procedures Controlling the Video Input and Monitors Controlling the Spot MonitorSelecting the Spot Monitor Single Spot LiveZooming Single Spot Live Controlling the Multiscreen MonitorSelecting the Multiscreen Monitor Group Single Sequence Live All Input Display with Quad Shift Off Multiscreen Spot LiveMultiscreen Select Multi Sequence Live All Input Display with Quad Shift On Group DisplayMulti Group setting Quad setting Group Multi SequenceAlarm Operation Alarm Control FunctionAlarm Input Alarm Reset Alarm SuspensionManual Reset Auto ResetInternal Timer Recording Power-on Time Lapse RecordingRecording Manual RecordingSet to ALM-ONLY Alarm RecordingAlarm Recording for Manual and Power-on Recording Time Lapse Recording Alarm Recording for Internal Timer ModesSet to ALM-MULTI Emergency Recording Playback Basic PlaybackStop Forward or Backward searchAlarm jump search Search Record FunctionJump search Record ListTime & Date Search Alarm Log SearchDisplay Zooming Single Spot Playback Display on the MonitorSingle and Multiscreen Spot Playback Displaying Camera and Playback Image REC PreviewBackup Function JogDialALM-VMD2 Total 931RECORD Data Erase Function Auto Erase FunctionManual Erase Function Lock To release this function, follow the procedure belowButton Locked Function Playback of Backup Data Specifications Standard AccessoryGeneral Input and OutputN1102-0 V8QA6084AN