6.Move the cross pointer on the screen to the starting point for the area by pressing the A, B, D or C but- ton, then press the SET button.
1+
AREA SET/ERASE:PRESS[SET] AT CORNER
7.Move the cross pointer on the screen to the ending point for the area by pressing the A, B, D or C but- ton, then press the SET button to determine the rectan- gular detecting area.
1
+
AREA SET/ERASE:PRESS[SET] AT CORNER
Four detecting areas can be set on the screen.
To assign another detecting area, repeat the above steps 6 and 7.
8.To delete the area, move the cursor to the rectangle to be delete on the screen, then press the SETUP/ESC button.
9.To return to the previous table, press the SETUP/ESC button.
10.Repeat the above steps 4 to 9 to set the detector func- tion for other cameras.
11.Press the SETUP/ESC button to return to the previous ALARM SETUP menu.
Note: If the unit detects moving objects frequently, the unit slows down the front buttons’ response because making records of moving objects have a higher priority.
In this case, set up the detecting area, sensitivity, etc. again.
■Alarm Mode on the Multiscreen Monitor
This item lets you select the mode for displaying an alarm on the Multiscreen Monitor.
1.Move the cursor to the ALARM MODE MULTI OUTPUT in the ALARM SETUP menu by pressing the D or C button.
2.Select either SPOT or OFF by pressing the + or - but- ton.
SPOT: The camera image that has activated the alarm is displayed in single spot mode.
OFF: Ignores alarm activation and continues to display the images in the mode selected previously.
The factory default setting is SPOT.
■Alarm Mode on the Spot Monitor
This item lets you select the mode for displaying an alarm on the Spot Monitor.
1.Move the cursor to the ALARM MODE SPOT OUTPUT in the ALARM SETUP menu by pressing the D or C but- ton.
2.Select either SPOT or OFF by pressing the + or - but- ton.
SPOT: The camera image that has activated the alarm is displayed in single spot mode.
OFF: Ignores alarm activation and continues to display the images in the mode selected previously.
The factory default setting is SPOT.