Panasonic WJ-HD500B manual One Shot Recording Internal Timer

Page 55

7.Move the cursor to the DYNAMIC REC parameter by pressing the D or C button, then select the recording pattern for post-recording by pressing the + or - but- ton.

OFF: Records the images assigned to group inputs, including the one that has activated the alarm (the same as pre-recording).

ALM-ONLY:Records the particular image that has acti- vated the alarm.

The factory default setting is OFF.

8.Move the cursor to the AUTO COPY parameter by pressing the D or C button, then select alarm backup mode by pressing the + or - button.

OFF: Disables alarm data backup.

ON: Enables alarm data backup. The factory default setting is OFF.

9.Press the SETUP/ESC button to return to the previous program number menu.

One Shot Recording (Internal Timer)

As described before, the One Shot Recording is an event recording function reacting to an alarm input.

It records the number of particular images that have acti- vated the alarm.

These items let you determine the recording parameters for One Shot Recording assigned in the program number menu.

(continued from Program Timer)

1.Select the recording mode O/S in the program number menu by pressing the + or - button, then press the SET button.

The selected One Shot Recording menu as shown below appears on the monitor screen.

3-1-1-1 PROG1-NO1-G1 REC SETUP

O/S(EVENT:ONE SHOT)

 

TRIGGER ACTION

REC+ALM

REC MODE

 

REC RATE

15FPS

REC QUALITY

SUPER FINE

PICTURES

16

AUTO COPY

OFF

2.Move the cursor to the TRIGGER ACTION parameter in the menu by pressing the D or C button, then select an active mode for group cameras when an alarm is received by pressing the + or - button.

REC+ALM: Enables alarm recording and alarm activa- tion.

REC: Enables only alarm recording.

The ALARM display on the monitor is also disabled. The factory default setting is REC+ALM.

3.Move the cursor to the REC RATE parameter in the menu by pressing the D or C button, then select the desired recording rate by pressing the + or - button.

1 - 60FPS: Records the selected number of the freeze image per second.

The factory default setting is 15FPS.

Notes:

The maximum recording rate depends on the selected parameters in the COMMON SETUP menu as shown in the table.

FIELD/FRAME

CAMERA GENLOCK

REC RATE

FIELD

ON

60FPS

 

OFF

30FPS

FRAME 3DIM

ON

10FPS

ON

OFF

10FPS

FRAME 3DIM

ON

30FPS

OFF

OFF

15FPS

“FPS” indicates as field per second or frame per second when the FIELD/FRAME parameter is set to FIELD or FRAME in the menu.

4.Move the cursor to the REC QUALITY parameter by pressing the D or C button, then select the desired image quality by pressing the + or - button.

SUPER FINE: For enhanced sharpness (Compression Rate 1/6)

FINE: For fine image quality (Compression Rate 1/10)

NORMAL: For normal image quality (Compression Rate 1/16)

EXTENDED: For extended time recording quality (Compression Rate 1/25)

The factory default setting is SUPER FINE.

5.Move the cursor to the PICTURE parameter by pressing the D or C button, then select the number of freeze images to be recorded by pressing the + or - button.

4 to 60: Records the selected number of freeze images for One Shot Recording.

The factory default setting is 16.

6.Move the cursor to the AUTO COPY parameter by pressing the D or C button, then select an alarm back- up mode by pressing the + or - button.

OFF: Disables backup for alarm recording.

ON: Enables backup for alarm recording. The factory default setting is OFF.

7.Press the SETUP/ESC button to return to the previous program number menu.

55

Image 55
Contents Operating Instructions Lightning flash with arrowhead symbol Contents Easy image search FeaturesPreface Reliable recording of eventsPrecautions Front View 2Set Button SET @4Alarm Search Button Alarm Search@8Setup/Escape Button SETUP/ESC 1Numeric Buttons 1$22Spot Output Connector Spot OUT @9Direction Buttons CDA B #0Full Indicator Full#1Hard Disk Drive Indicator HDD $1Multiscreen Output Connector Multiscreen OUT8Power Switch Power ON/OFF $7Alarm Port Alarm$9Mode Selector Mode 2Gen-lock Output Connector GEN-LOCK OUT3Multiscreen Selection Button WV-CU50 Remote Controller1Lock Button Lock 2Monitor Selection Button6Electronic Zoom Button EL-ZOOM 9Alarm Search Button Alarm Search1Link Indicator Link Blinking Pause mode 0JogDialInstalling the Optional Hard Disk InstallationInstalling the Optional Network Board Installing the Optional Motion Detector Board Mounting into the Rack Shown below are examples of system connections ConnectionsBasic System System ExpansionConnection with the Camera Sites Connection with the Remote ControllerConnection with the Monitors Alarm Alarm Port ConnectionControl Port Connection Connection with Control output Connection with the Uninterrupted Power Supply UPSMode Switch SettingConnection with the Extension Units Scsi ConnectionConnection with the DVD Extension Unit Switch SettingsConnection with the DVD Extension Unit without HDD Copy WJ-HDE510B EXT Connection with the DVD Extension Unit with HDDConnection to PS Data Compatible Equipment Mode Selector Setting10/100BASE-T Port Connection Serial Port ConnectionPage Preparations Power UP Procedure Formatting the Hard Disk 1DISK Format Formatting the DVD-RAM Disk Mirroring Function To deactivate the mirror function Disk Remove Time Display Monitors and DisplaysSpot and Multiscreen Monitor Status DisplayElectronic Zoom Display Format Error orSystem Status Display Group DisplayEmergency Recorder Timer RecorderHard Disk Manual RecorderMulti Shot Recording Time Lapse RecordingDynamic Recording is set to OFF Dynamic Recording is set to ALM-ONLY One Shot RecordingPage Setup Procedures Displaying the Setup Menu Setup MenuSetup Timer Setting Recording Setup Programming Menu SetupDisplay Setup Communication Setup Timer Setting Color Mode Setting Recording SetupRecording Quality Setup Video Pixels ResolutionSpace Group SetupGroup Title Setup Camera AssignmentRecording of the Title Display Thumbnail Display SetupPlayback Mode Setup Shuttle Speed SetupManual Recording Mode Setting Hard Disk End Setup→ Manual with Audio → Manual Without Audio → Event Recording Manual Recording Program Timer Alarm Active Mode Manual RecordingSpecial Day Timer Time Lapse Recording Internal Timer External Program TimerEvent Recording Alarm Active ModeMulti Shot Recording Internal Timer One Shot Recording Internal Timer Emergency Recording Time Lapse Recording Live Sequence Multiplexer SetupSequence Setup Multiscreen Monitor Live Sequence Pattern SettingQuad Pattern Setup Quad Shift SettingSequence Timing Setting Live Sequence Pattern Setting Sequence Setup Spot MonitorGroup Multi Sequence Setting Auto Skip SettingPower on Setting Spot Monitor Power on Setting Multiscreen MonitorSequence Timing Setting Secret View Setting Alarm Output Setting Alarm SetupAlarm Port Setting Alarm Auto Reset SettingVideo Loss Alarm Setting Alarm Buzzer SettingVideo Motion Detector Setting Alarm Mode on the Spot Monitor Alarm Mode on the Multiscreen MonitorClock Display Display SetupCamera Title Setup Display Setting Multiscreen MonitorStatus Display Title Display Setting Spot MonitorAlarm Display Setting Title DisplayTitle Display Position Setting Clock and Status Display Position SettingBaud Rate Communication SetupPS Data Setup Unit Address SettingStop Bit Alarm DataInput Camera Number Setup Parity CheckRS-232C Setup Network Setup SET Time System SetupClock Setup Time Adjustment SettingAuto Button Locked Setting Password Lock SettingBuzzer Setting User Defined SettingDisk Management Disk Space IndicatorDisk Information System Information Error ReportAlarm Recording Backup DVD Drive SetupDVD Format DVD Disk End Setup Emergency Recording BackupDisk Space Display Page Operating Procedures Single Spot Live Controlling the Video Input and MonitorsControlling the Spot Monitor Selecting the Spot MonitorSelecting the Multiscreen Monitor Controlling the Multiscreen MonitorZooming Single Spot Live Group Single Sequence Live Multiscreen Select Multiscreen Spot LiveAll Input Display with Quad Shift Off All Input Display with Quad Shift On Group Display Multi Sequence LiveGroup Multi Sequence Multi Group setting Quad settingAlarm Input Alarm Control FunctionAlarm Operation Auto Reset Alarm ResetAlarm Suspension Manual ResetManual Recording Internal Timer RecordingPower-on Time Lapse Recording RecordingAlarm Recording for Manual and Power-on Recording Alarm RecordingSet to ALM-ONLY Set to ALM-MULTI Alarm Recording for Internal Timer ModesTime Lapse Recording Emergency Recording Forward or Backward search PlaybackBasic Playback StopRecord List Alarm jump searchSearch Record Function Jump searchDisplay Alarm Log SearchTime & Date Search Single and Multiscreen Spot Playback Display on the MonitorZooming Single Spot Playback REC Preview Displaying Camera and Playback ImageJogDial Backup FunctionALM-VMD2 Total 931RECORD Auto Erase Function Data Erase FunctionManual Erase Function Button Locked Function To release this function, follow the procedure belowLock Playback of Backup Data Input and Output SpecificationsStandard Accessory GeneralN1102-0 V8QA6084AN