Function menus
50P IN/OUT ASSIGN
<50P IN/OUT ASSIGN>
50-pin assignment factory settings
Pin | I/O | Setting item |
no. |
| |
|
| |
|
|
|
|
|
|
1 | I | REC |
|
|
|
2 | I | PLAY |
|
|
|
3 | I | FF |
|
|
|
4 | I | REW |
|
|
|
5 | I | STOP |
|
|
|
6 | I | ___ |
|
|
|
7 | I | ___ |
|
|
|
8 | I | 422 REMOTE ON |
|
|
|
9 | I | 422 REMOTE OFF |
|
|
|
10 | I | LOCAL ENABLE |
|
|
|
11 | I | EJECT |
|
|
|
12 | I | IN SET |
|
|
|
13 | I | REC INH ALL |
|
|
|
14 | I | REC INH PRE |
|
|
|
15 | I | LOCAL DISABLE |
|
|
|
16 | I | TC EXT |
|
|
|
17 | I | TC INT&TCG MODE AUTO |
|
|
|
18 | I | ___ |
|
|
|
19 | I | ___ |
|
|
|
20 | I | STNDBY ON/OFF |
|
|
|
21 | O | ERR0 STATUS |
|
|
|
22 | I | DET STOP ON |
|
|
|
23 | I | CUE |
|
|
|
24 | O | ERR1 STATUS |
|
|
|
25 | I | DET STOP OFF |
|
|
|
26 | Power |
|
|
|
|
27 | O | REC STATUS |
|
|
|
28 | O | PLAY STATUS |
|
|
|
29 | O | FF STATUS |
|
|
|
30 | O | REW STATUS |
|
|
|
31 | O | STOP STATUS |
|
|
|
32 | O | 422 REMOTE STATUS |
|
|
|
33 | O | EJECT STATUS |
|
|
|
34 | O | ERR2 STATUS |
|
|
|
35 | O | TC SRC1 STATUS |
|
|
|
36 | O | TC SRC2 STATUS |
|
|
|
37 | O | ___ |
|
|
|
38 | O | ___ |
|
|
|
39 | O | REC INH1 STATUS |
|
|
|
40 | O | REC INH2 STATUS |
|
|
|
Pin | I/O | Setting item |
no. |
| |
|
| |
|
|
|
|
|
|
41 | O | CUE STATUS |
|
|
|
42 | O | REMOTE STATUS |
|
|
|
43 | O | DET STOP STATUS |
|
|
|
44 | O | PRE CTL DETECTED STATUS |
|
|
|
45 | O | LOCAL ENABLE STATUS |
|
|
|
46 | O | STANDBY ON STATUS |
|
|
|
47 | GND |
|
|
|
|
48 | O | ___ |
|
|
|
49 | GND |
|
|
|
|
50 | GND |
|
|
|
|
__
“ ” denotes that nothing is subject to control or to a status.
<Notes>
•For a command, input TTL level signals; for an active low edge, input an electrical signal of 100 ms
or more.
•For a status, a maximum open collector and sink current of 6 mA is output.
77