Setup menus
<TIME CODE>
No./Item |
|
|
| Description of setting | |
|
|
|
|
| |
|
|
|
|
| |
500* 4 | For selecting whether or not to output the | ||||
| VITC signal at the positions selected by setup | ||||
VITC BLANK | menu items No.501 (VITC | ||||
| (VITC |
| |||
| 0000 | BLANK | : The VITC signal is not output. | ||
|
| 0001 | THRU | : The VITC signal is output. | |
|
|
|
|
|
|
<Note>
Only the SD output takes effect at this setting.
501*4 | For setting the position where the VITC signal | |||||||
| is to be inserted. |
|
|
|
| |||
VITC | <59/60Hz> |
| <50Hz, 25Hz (SD)> | |||||
| 0000 |
| 10L | 0000 |
|
| 7L | |
| : | : | : | : | ||||
| 0006 |
| 16L | 0004 |
| 11L | ||
|
|
|
|
|
|
|
|
|
|
| : | : | : | : | |||
| 0010 |
| 20L | 0015 |
| 22L |
<Notes>
•The same line as the one selected by the setup menu item No.502 (VITC
•Only the SD output takes effect at this setting.
502*4 | For setting the position where the VITC signal | |||||||||
| is to be inserted. |
|
|
|
| |||||
VITC | <59/60Hz> |
|
|
| <50Hz, 25Hz (SD)> | |||||
| 0000 |
| 10L | 0000 |
|
| 7L | |||
| : | : | : | : | ||||||
| 0008 |
|
| 18L | 0006 |
| 13L | |||
|
|
|
|
|
|
|
|
|
|
|
|
| : | : | : | : | |||||
| 0010 |
| 20L | 0015 |
| 22L |
<Notes>
•The same line as the one selected by the setup menu item No.501 (VITC
•Only the SD output takes effect at this setting.
503*1 | For setting the synchronization of the internal | ||||||||||
| time code generator. |
|
|
|
| ||||||
TCG MODE | 0000 | REGEN | : |
|
|
|
| ||||
|
| The time code reader is synchronized with the | |||||||||
|
| time code which is read from the tape. |
|
| |||||||
| 0001 |
| PRE | : |
|
|
|
| |||
|
| Presetting is enabled at the operation panel or | |||||||||
|
| by the remote controller. |
|
|
|
| |||||
| 0002 |
| AUTO | : |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
| The | REGEN |
| and | PRE | settings | are | |||
|
| automatically switched in accordance with the | |||||||||
|
| operation mode. |
|
|
|
|
|
| |||
|
| In the editing mode: REGEN is selected. |
| ||||||||
|
| In all other modes: PRE is selected. |
| ||||||||
|
|
|
|
|
|
|
| ||||
504*1 | For setting | when the | internal |
| time | code | |||||
| generator is to advance depending on the |
| |||||||||
RUN MODE | operation mode. |
|
|
|
|
|
| ||||
| 0000 |
| REC | : |
|
|
|
| |||
|
|
|
|
|
|
| |||||
|
| The time code generator is advanced during |
| ||||||||
|
| recording. |
|
|
|
|
|
|
|
| |
| 0001 | FREE | : |
|
|
|
| ||||
|
| The time code generator is advanced while the |
| ||||||||
|
| power is | on | regardless | of which | operation | |||||
|
| mode is established. |
|
|
|
|
*1: This item is not displayed when the 23/24 Hz or 25 Hz (HD or SD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.
*2: This item is not displayed when the 23/24 Hz or 25 Hz (HD) mode has been selected as the system menu item No.25 (SYSTEM FREQ) setting.
The underlining (__) denotes the factory setting mode.
No./Item |
|
|
|
| Description of setting |
| |||||
|
|
|
| ||||||||
|
|
|
| ||||||||
505*1 | For selecting the | regeneration | signal when | ||||||||
| REGEN has been selected as the TCG (time | ||||||||||
TCG REGEN | code generator) mode. |
|
|
|
| ||||||
| 0000 |
| TC&UB |
| : |
|
|
|
| ||
|
|
|
|
|
|
|
| ||||
|
| Regeneration applies to both the time | code | ||||||||
|
| and user’s bit. |
|
|
|
|
|
| |||
| 0001 |
| TC |
| : |
|
|
|
| ||
|
| Regeneration applies only to the time code only. | |||||||||
| 0002 |
| UB |
| : |
|
|
|
| ||
|
| Regeneration applies only to the user’s bit only. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
506*1 | For selecting the | editing | mode | range when | |||||||
| the VTR is operating in the REGEN mode | ||||||||||
REGEN MODE | while | performing editing | operations | with | |||||||
| “AUTO” selected as the setup menu item | ||||||||||
| No.503 (TCG MODE) setting. |
|
|
| |||||||
| 0000 |
| AS&IN |
| : |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
| Regeneration | applies | during | assemble | or | |||||
|
| insert editing. |
|
|
|
|
|
| |||
| 0001 | ASSEM |
| : |
|
|
|
| |||
|
| Regeneration applies during assemble editing. | |||||||||
| 0002 | INSRT |
| : |
|
|
|
| |||
|
| Regeneration applies during insert editing. |
| ||||||||
|
|
|
|
|
|
| |||||
507*1 | For selecting the time code to be used when | ||||||||||
| HD SDI | or SD SDI has been selected as the | |||||||||
TC SOURCE | setup | menu item No.600 (VIDEO IN SEL) | |||||||||
| setting when an external time code is to be | ||||||||||
| used. |
|
|
|
|
|
|
|
|
| |
| [When HD SDI has been selected] |
|
| ||||||||
| 0000 |
| INT | : |
|
|
|
| |||
|
|
|
|
|
| ||||||
|
| The | time code of the internal time code | ||||||||
|
| generator is used. |
|
|
|
|
| ||||
| 0001 | EXT_L |
| : |
|
|
|
| |||
|
| LTC of the TIME CODE IN connector is used. | |||||||||
| 0002 |
| SLTC |
| : |
|
|
|
| ||
|
| The | LTC information added to the | serial | |||||||
|
| signals which are input to HD SDI IN is used. | |||||||||
| 0003 | SVITC |
| : |
|
|
|
| |||
|
| The VITC information added to the serial | |||||||||
|
| signals which are input to HD SDI IN is used. | |||||||||
| [When SD SDI has been selected] |
|
| ||||||||
| 0000 |
| INT | : |
|
|
|
| |||
|
|
|
|
|
| ||||||
|
| The | time code of the internal time code | ||||||||
|
| generator is used. |
|
|
|
|
| ||||
| 0001 | EXT_L |
| : |
|
|
|
| |||
|
| LTC of the TIME CODE IN connector is used. | |||||||||
| 0002 |
| VITC |
| : |
|
|
|
| ||
|
| The VITC information added to the serial | |||||||||
|
| signals which are input to SD SDI IN is used. | |||||||||
| <Note> |
|
|
|
|
|
| ||||
| If the VIDEO IN SEL input selection is changed, the time | ||||||||||
| code is converted as shown below. |
|
|
|
| ||||||
| [HD_SDI] |
| [SD_SDI] |
|
| ||||||
| INT |
|
| ↔ | INT |
|
|
| |||
| EXT_L |
|
| ↔ | EXT_L |
|
|
| |||
| SLTC |
|
| ↔ | EXT_L |
|
|
| |||
| SVITC |
|
| ↔ | VITC |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
91