Setup menus
<INTERFACE>
No./Item |
|
|
|
|
|
|
| Description of setting |
|
| ||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| |||||||
200 | For selecting whether to operate two or more |
| ||||||||||||
| VTRs in synchronization. |
|
|
|
| |||||||||
PARA RUN | 0000 |
|
|
|
| DIS | : The | VTRs are not operated in | ||||||
|
|
|
|
|
|
|
|
|
|
| synchronization. |
| ||
| 0001 |
|
| ENA | : | The | VTRs | are operated in | ||||||
|
|
|
|
|
|
|
|
|
|
| synchronization. |
| ||
| <Note> |
|
|
|
|
|
|
|
|
|
|
| ||
| To operate the VTRs in synchronization, set all the | |||||||||||||
| VTRs to 1 (ENA). (Refer to pages 14 and 19.) |
| ||||||||||||
|
|
|
|
|
|
| ||||||||
202 | For | setting what |
| ID information is to be | ||||||||||
| returned to the controller. |
|
|
| ||||||||||
ID SEL | 0000 |
| OTHER |
|
|
|
|
|
| |||||
|
| 0001 |
|
| DVCPRO |
|
|
|
|
|
| |||
| 0002 |
|
| ORIG |
|
|
|
|
|
| ||||
| <Notes> |
|
|
|
|
|
|
|
|
|
|
| ||
| • | For 0 (OTHER), the ID information of VTRs other than | ||||||||||||
|
| DVCPRO models is set. |
|
|
|
| ||||||||
| • | Select 2 (ORIG) only when the VTR is connected to a | ||||||||||||
|
| Panasonic controller (such as the | an | |||||||||||
|
| optional accessory). |
|
|
|
|
|
| ||||||
| • | Select 1 (DVCPRO) or 2 (ORIG) if the 23/24 Hz mode | ||||||||||||
|
| has been selected by system menu item No.25 |
| |||||||||||
|
| (SYSTEM FREQ). |
|
|
|
|
|
| ||||||
|
|
|
| |||||||||||
204 | For selecting whether the |
| ||||||||||||
| is to function. |
|
|
|
|
|
| |||||||
RS232C SEL | 0000 |
|
|
|
| OFF | : | The | connector | does | ||||
|
|
|
|
|
|
|
|
|
|
| not function. |
|
| |
| 0001 |
|
|
| ON | : The | ||||||||
|
|
| ||||||||||||
205 | For setting the |
| ||||||||||||
| (baud rate). |
|
|
|
|
|
| |||||||
BAUD RATE | 0000 |
| 300 |
|
|
|
|
|
| |||||
| 0001 |
| 600 |
|
|
|
|
|
| |||||
| 0002 |
| 1200 |
|
|
|
|
|
| |||||
| 0003 |
| 2400 |
|
|
|
|
|
| |||||
| 0004 |
| 4800 |
|
|
|
|
|
| |||||
|
| 0005 |
| 9600 |
|
|
|
|
| |||||
|
|
|
| |||||||||||
206 | For setting the |
| ||||||||||||
| (Unit: bits) |
|
|
|
|
|
| |||||||
DATA | 0000 |
| 7 |
|
|
|
|
|
| |||||
LENGTH |
| 0001 |
| 8 |
|
|
|
|
| |||||
|
|
|
| |||||||||||
207 | For setting the number of |
| ||||||||||||
| (Unit: bits) |
|
|
|
|
|
| |||||||
STOP BIT |
| 0000 |
| 1 |
|
|
|
| ||||||
| 0001 |
| 2 |
|
|
|
|
|
| |||||
|
| |||||||||||||
208 | For setting whether the | |||||||||||||
| to be used and, if it is used, whether even or | |||||||||||||
PARITY | odd parity is to apply. |
|
|
|
| |||||||||
|
| 0000 |
|
| NON | : |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||||
|
| The parity bit is not used. |
|
|
| |||||||||
| 0001 |
|
| ODD | : |
|
|
|
| |||||
|
| The parity bit is used with an odd parity. |
| |||||||||||
| 0002 |
|
| EVEN | : |
|
|
|
| |||||
|
| The parity bit is used with an even parity. |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The underlining (__) denotes the factory setting mode.
No./Item |
|
|
| Description of setting | |||
|
|
|
|
| |||
|
|
|
|
| |||
209 | For setting whether or not to return the ACK | ||||||
| code when a command is received from RS- | ||||||
RETURN ACK | 232C. |
|
|
|
| ||
| 0000 |
| OFF | : | The ACK code is not returned. | ||
|
| 0001 |
| ON | : | The ACK code is returned. | |
|
|
|
|
|
| ||
212 | For selecting the remote control connector | ||||||
| for controlling the slave machine when this | ||||||
MASTER | VTR is to be used as the master machine for | ||||||
PORT |
| ||||||
|
| 0001 |
| IN/OUT | : | The IN/OUT connector is used. | |
| 0001 |
| OUT | : | The OUT connector is used. | ||
| <Note> |
|
|
|
| ||
| This setting takes effect only when the 9P button has | ||||||
| been set to LOCAL (LED off). | ||||||
|
|
|
|
|
|
|
|
87