Error messages
Warning messages
|
|
| • Display |
| |
Priority | • Description |
| |||
|
|
| • VTR operation and remedial action |
| |
|
|
|
|
|
|
|
|
|
|
|
|
Higher | FAN STOP |
|
| ||
This is displayed when the fan motor has stopped. |
| ||||
|
|
|
| ||
|
|
| VTR: | Operation continues (and a warning beep is sounded |
|
|
|
| regardless of the menu setting.) |
| |
|
|
| • Check that no foreign matter has accumulated on the fan. |
| |
|
|
|
|
|
|
|
|
| NO RF |
|
|
|
|
| This is displayed when a blank part of the tape lasting for 1 |
| |
|
|
| or more seconds has been detected during playback. |
| |
|
|
| When all of the following conditions have been met, it will be |
| |
|
|
| recognized as a blank part. |
| |
|
|
| • When no signals are output from any of the heads |
| |
|
|
| • When the playback data cannot be read |
| |
|
|
| • When the CTL signal is not present |
| |
|
|
| VTR: | Operation continues. |
|
|
|
| • Check the tape. An unrecorded tape may have been |
| |
|
|
| inserted. |
| |
|
|
|
|
| |
|
|
| SERVO NOT LOCKED |
| |
|
|
| This is displayed when the servo is not locked for 3 or more |
| |
|
|
| seconds during playback, recording or editing. |
| |
|
|
| VTR: | Operation continues. |
|
|
|
| • Check the tape. A tape recorded using a system which |
| |
|
|
| does not allow playback may have been inserted | . | |
|
|
|
|
| |
|
|
| INVALID TC MODE (in 23/24 Hz or 25 Hz (HD or SD) |
| |
|
|
| mode) |
|
|
|
|
| This is displayed during playback if the time code has been |
| |
|
|
| recorded in the drop frame mode. The video output is |
| |
|
|
| disturbed and the audio output is muted at the time code |
| |
|
|
| drop point. |
| |
|
|
| VTR: | Operation continues. |
|
•Check the tape. If a tape recorded using a variable frame rate camera is to be played back in this VTR, the time code must be recorded in the
TC SEQUENCE UNMATCH (in 23/24 Hz or 25 Hz (HD or
SD) mode)
This is displayed during playback if the correlation between the active frame information and time code is irregular. The video output may not be uniform (the movements may not be smooth).
VTR: Operation continues.
•Check the tape. The active frame (first frame where the frame video is switched) information is recorded on a tape recorded using a variable frame rate camera. When such a tape is played back on this VTR, the 0 frame of the time code must be detected at the active frame position.
LOW RF
This is displayed when a state in which the envelope level has dropped to less than
•The CTL signal level is not detected during DV or DVCAM playback.
•During recording or editing, the envelope level of only the video simultaneous play heads is detected.
VTR: Operation continues.
• Clean the video heads and A/C head.
|
| HIGH ERROR RATE | ||
|
| This | is displayed when the error rate increases and | |
|
| correction or interpolation is performed for either the video | ||
|
| or audio signals. | ||
|
| |||
|
| |||
Lower | VTR: | Operation continues. | ||
• Clean the video heads. | ||||
|
|
Error messages
Display | • Description |
| ||
• VTR operation and remedial action |
| |||
|
|
| ||
|
|
|
|
|
|
|
|
|
|
CAP ROTA |
| If | the rotational speed of the capstan motor | is |
TOO SLOW |
| abnormally slow, the AUTO OFF lamp lights, and the |
| |
|
| message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
| ||
CAP TENSION | If an abnormal tension is detected at the supply side in |
| ||
ERROR |
| the capstan mode, the AUTO OFF lamp lights, and the |
| |
|
| message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
|
| |
DEW |
| When condensation has been detected, the AUTO OFF |
| |
|
| lamp lights, the message display blinks, and the VTR |
| |
|
| transfers to the EJECT mode. After the tape has been |
| |
|
| ejected, the drum continues to rotate in order to dry out |
| |
|
| the condensation. |
| |
|
| When the condensation has cleared, the AUTO OFF |
| |
|
| lamp goes off, the message display is cleared, and the |
| |
|
| VTR is ready for operation again. |
| |
|
| • When condensation is detected in the EJECT mode, |
| |
|
| the drum starts rotating as soon as it is detected. |
| |
|
| • When condensation is detected while a cassette is |
| |
|
| inserted, the drum stops rotating and starts rotating |
| |
|
| again after the tape has been ejected. |
| |
|
| VTR: | EJECT |
|
|
| • Wait with the power on. |
| |
|
|
|
|
|
DRUM ROTA |
| If | the rotational speed of the cylinder motor | is |
TOO FAST |
| abnormally high, the AUTO OFF lamp lights, and the |
| |
|
| message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
|
|
|
DRUM ROTA |
| If | the rotational speed of the cylinder motor | is |
TOO SLOW |
| abnormally slow, the AUTO OFF lamp lights, and the |
| |
|
| message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
|
| |
| If the tape start and tape end are detected at the same |
| ||
|
| time either during or after loading, the AUTO OFF lamp |
| |
|
| lights, and the message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
|
| |
FRONT | LOAD | If the |
| |
ERROR |
| for a specific period of time during the tape start or end |
| |
|
| processing operation while loading is being performed |
| |
|
| (at the half position), the AUTO OFF lamp lights, and | ||
|
| the message display blinks. |
| |
|
| VTR: | Stops. |
|
|
| • Set the POWER switch to OFF and then back to ON | ||
|
| again. |
| |
|
|
|
|
|