Peerless Industries PP740-S manual Installation to Solid Concrete and Cinder Block

Page 6

Installation to Solid Concrete and Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

2

Level and use wall plate as template to mark center

of holes. Drill two 5/16" (8 mm) dia. holes to a

minimum depth of 2.5" (64 mm). Insert anchors (B) in holes flush with wall. Place wall mount (A) over anchors and secure with wood screws (H). Make sure wall mount is level, and tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached,

 

but do not overtighten. Overtightening can damage

 

screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to

1

concrete

surface

B

Drill holes and insert anchors (B).

2

A

 

 

H

B

Place plate (A) over anchors (B) and secure with screws (H).

load-be aring concrete.

• Never attach concrete expansion anchors to concrete

covered with plaster, drywall, or other finishing mate-

rial. If mounting to concrete surfaces covered with a

finishing surface is unavoidable, the finishing surface

must be counterbored as shown below. Be sure con-

crete anchors do not pull away from concrete when

tightening screws. If plaster/drywall is thicker than

5/8" (16 mm), custom fasteners must be supplied by

installer. (not evaluated by UL)

3

Tighten all fasteners.

SOLID CONCRETE

CINDER BLOCK

 

 

INCORRECT

CORRECT

VIEW

wall

concrete

wall

concrete

 

plate

 

plate

 

 

 

 

 

CUTAWAY

 

plaster/

 

plaster/

 

drywall

 

drywall

 

 

 

 

B

WALL PLATE

H A

6 of 46

ISSUED: 01-15-08 SHEET #: 095-9282-2 06-12-09

Image 6
Contents Features Tools Needed for Assembly Table of ContentsParts List Screws Installation to Wood Stud Wall Installation to Solid Concrete and Cinder Block Always attach concrete expansion anchors directly toShown For Vesa 200 x 100 Mounting PatternFor Vesa 200 x 200 Mounting Pattern Choose hole pattern as shown below. Attach hook Bracket M to back of screen using four M4 xFor Vesa 75 Mounting Pattern For Vesa 100 Mounting PatternInstalling and Removing Flat Panel Screen Attaching Tilt Knob to Wall Mount optionalCord Management 20 X 1/2 ScrewsArm Tension Adjustment Tension ScrewsCaracterísticas Español Herramientas necesarias para el ensamblajeTabla de contenido Construcción DE LA Pared Accesorios NecesariosLista de piezas 14 de15 de Instalación en una pared con montantes de madera dobles 16 de17 de Incorrecto CorrectoEN EL Caso DE LA Configuración DE MON- Taje Vesa 200 x 18 deEN EL Caso DE LA Configuración DE Montaje Vesa 19 deInstalación y desinstalación de la pantalla plana 20 deManejo de Cables 21 deAjuste Tensor del Brazo 22 deCaractéristiques Français Outils nécessaires au montageTable des matières Type DE MUR Pièces DE Fixation RequisesListe des pièces 25 sur26 sur Installation sur un mur à montant en bois simple 27 surBéton Plein Mâchefer 28 surPour LA Configuration DE Montage Vesa 200 x 29 surVesa Pour LA Configuration DE MontagePour LA Configuration DE Montage Vesa 30 surFixation du Bouton DInclinaison au Support Mural facultatif Montage et démontage d’un écran plat31 sur Organisation des Câbles 32 surRéglage de la tension du bras 33 surMerkmale Deutsch Für den Zusammenbau erforderliche WerkzeugeInhaltsverzeichnis Wandkonstruktion Erforderliche BefestigungsteileTeileliste 20 X 1/2 Zoll Schrauben Anbringung an Wand Holzständerreihen Anbringung an Massivbeton oder Porenbetonstein 39 vonAchtung BEI Montagemuster Vesa 200 xBefestigung AN PEERLESS-ADAPTERHALTER- UNG Modell PLP BEI Montagemuster VesaAnbringung des Neigungsknopfs am Wandhalter optional Anbringung und Abnahme des FlachbildschirmsKabelführung Einstellung der Armspannung Spannungss ChraubenLimited FIVE-YEAR Warranty Garantie DE Cinq ANS