Peerless Industries PWS421 Installation to Solid Concrete or Cinder Block, Incorrect Correct

Page 5

Installation to Solid Concrete or Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.

Make sure that wall plate (AA) is level, use it as a

1 template to mark four mounting holes. The top mounting hole should be 2.5" (64 mm) above the desired screen center as shown in figure 1.1 on page 4. Drill four 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (EE) in holes flush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (DD). Level, then tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to load-bearing concrete.

1

concrete

surface

EE

Drill holes and insert anchors (EE).

2

AA

 

 

DD

EE

Place plate (AA) over anchors (EE) and secure with screws (DD).

3

• Never attach concrete expansion anchors to

 

 

 

concrete covered with plaster, drywall, or other

 

 

 

Tighten all fasteners.

finishing material. If mounting to concrete surfaces

covered with a finishing surface is unavoidable (not

 

 

 

evaluated by UL), the finishing surface must be

 

 

 

counterbored as shown below. Be sure concrete

 

 

 

anchors do not pull away from concrete when

EE

tightening screws. If plaster/drywall is thicker than

5/8" (16 mm), custom fasteners must be supplied

by installer (not evaluated by UL).

 

 

 

 

 

INCORRECT

 

CORRECT

AA

VIEW

 

 

 

wall

concrete

wall

 

concrete

 

 

 

 

 

 

plate

 

 

 

 

plate

 

 

 

 

CUTAWAY

 

 

 

 

 

 

drywall

 

drywall

 

 

 

 

plaster/

 

plaster/

 

DD

 

 

 

 

 

 

solid

concrete

 

cinder

block

 

5 of 34

ISSUED: 02-05-09 SHEET #: 202-9272-4 04-12-10

Image 5
Contents Model PT660, PWS421/BK FeaturesTable of Contents Tools Needed for AssemblyParts List Installation to Double Wood Stud Wall Incorrect Correct Installation to Solid Concrete or Cinder BlockAttaching Tilt Brackets to Screen using Baffled Fastener Pack For Flat Back Screen Screen Adjusting the Tilt Angle of the Flat PanelCaracterísticas Modelos PT660, PWS421/BKContenido Herramientas necesarias para el ensamblajeEspañol Construcción DE LA Pared Accesorios Necesarios11 de Lista de piezas12 de Instalación en una pared con montantes de madera doblesIncorrecto Correcto 13 de14 de Instalación de los soportes inclinablesNotas 15 de 16 de Instalación y desinstalación de la pantalla planaAjustar el ángulo de inclinación de la pantalla Caractéristiques Modèles PT660, PWS421/BKFrançais Outils nécessaires au montageType DE MUR Pièces DE Fixation Requises 18 sur19 sur Liste des pièces20 sur Installation sur un mur à doubles montants en bois21 sur Plein22 sur Installation des support inclinablesRemarques 23 sur Pour les écrans à dos plat24 sur Installation de l’écran plat sur la plaque muraleRéglage de l’inclinaison de l’écran plat L US MerkmaleInhaltsverzeichnis Für den Zusammenbau erforderliche WerkzeugeDeutsch Wandkonstruktion Erforderliche Befestigungsteile27 von TeilelisteInstallation zu verdoppeln Holzständerreihe Falsch Richtig Installation zu massivbeton oder porenbetonsteinHinweise AchtungBildschirme mit flacher Rückseite Einstellung des Neigungswinkels des Flachbildschirms Anbringung und Abnahme des FlachbildschirmsAbbildung Abbildund.4.1Limited FIVE-YEAR Warranty Garantie DE Cinq ANS