Icom HF/VHF/UHF ALL MODE TRANSCEIVER manual Programmed scan operation, Memory scan operation

Page 47

MEMORY AND SCAN OPERATION 5

Programmed scan operation

Select VFO mode.

Select the desired operating mode.

The operating mode can also be changed while scan- ning.

Set [SQL] open or closed.

See page a left for squelch condition.

Select S2, then push [(F-1)SCN] to start the scan.

USB

S1 3 5 7 9

20 40

60dB

VFO A

 

Select

 

VFO mode

 

 

 

 

 

PO

5

10

 

CH

S2 SCN PRI V/M

Decimal point blinks while scanning.

When the scan detects a signal, the scan turns OFF, pauses or ignores it depending on the resume setting and the squelch condition.

During scan [TS] can be used only when resume is ON.

To cancel the scan push [(F-1)SCN].

F-1

then push [(F-1)SCN]

 

Note: If the same frequencies are programmed into the scan edge memory channels 1A and 1B, pro- grammed scan does not start.

Memory scan operation

Select memory mode.

Close the squelch with [SQL].

Select S2, then push [(F-1)SCN] to start the scan.

Decimal point blinks while scanning.

When the scan detects a signal, the scan stops or pauses depending on the resume setting.

To cancel the scan push [(F-1)SCN].

USB

S1

3

5

7

9

20

40

60dB

Select

memory mode

PO

 

 

 

 

5

 

10 MEMO CH

 

 

 

 

 

 

S2 SCN SEL V/M

 

F-1

then push [(F-1)SCN]

 

Note: Two or more memory channels must be pro- grammed for memory scan to start.

Select memory scan operation

Select memory mode.

Close the squelch with [SQL].

Select S2, then push [(F-1)SCN] to start the mem-

ory scan.

Decimal point blinks while scanning.

Push [(F-2)SEL] to change the memory scan to select memory scan.

Push [(F-2)SEL] for 2 sec. to clear all select memory

 

 

 

USB

 

 

 

 

Select

 

 

 

 

 

 

 

 

 

memory mode

S1

3

5

7

9

20

40

60dB

 

Designate

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

PO

 

 

 

5

 

 

10 MEMO CH

 

“S.”

S2 SCN SEL V/M

 

 

 

 

F-1

 

 

F-2

 

 

channels.

Push [(F-1)SCN], then [(F-2)SEL].

When the scan detects a signal, the scan stops or

Note: Two or more memory channels must be desig-

pauses depending on the resume setting.

nated as select memory channels for select memory

To cancel the scan push [(F-1)SCN].

scan to start.

 

Priority watch

Select VFO mode, then set a frequency.

Close the squelch with [SQL].

Set the desired memory channel as the watching

channel.

Select S2, then push [(F-2)PRI] to start the watch.

Decimal point blinks while scanning.

When the scan detects a signal, the scan pauses for 10 sec. or until the signal disappears, depend- ing on the resume setting.

To cancel the scan push [(F-2)PRI].

USB

 

 

 

 

 

Select

 

 

 

 

 

VFO mode

S1 3 5 7 9

20 40

60dB

VFO A

PO

5

10

CH

 

Select watching

 

 

S2 SCN PRI V/M channel

F-2

Push [(F-2)PRI].

 

Note: The paused condition when detecting a signal differs depending on the scan resume condition. resume on: pauses for 10 sec.

resume off: pauses until the signal disappears.

44

Image 47
Contents I706MKG Word Definition Rwarning PrecautionsTable of Contents 0MAIN Dial Tension Latch Panel DescriptionFront panel @2PREAMP/ATTENUATOR Switch P.AMP/ATT 2LOCK Switch LockFunction switches Function p VOX Function pSpeech Compressor p BREAK-IN pRear and side panels ACC Socket When connecting the ACC conversion cable OPC-599ACC PIN # Name Description Specifications Color Function display 1DOT Matrix Indicators3FUNCTION Indicators 4DSP IndicatorsHM-103 Schematic Diagram ➊UP/DOWN Switches UP/DN ➋LOCK Switch Lock➌PTT Switch PTT Microphone ConnectorGrounding Installation and ConnectionsPL-259 Connector Installation Example UnpackingFront panel separation InstallationSingle body mounting StandRtty Terminal Required connectionsAdvanced connections Connecting a NON-ICOM Power supply connectionsConnecting the PS-85 DC Power Supply Connecting a NON-ICOM DC Power SupplyExternal antenna tuners and linear amplifier Connecting the AH-4Connecting the AT-180 Connecting the IC-PW1Power OFF Frequency SettingWhen first applying power CPU resetting Initial settingsVFO VFO ModeMemory Mode pgs VFO descriptionBand selection Frequency settingProgrammable tuning steps Hz and 10 Hz tuning stepsSub dial function MHz quick tuning stepTS Switch Flow Chart SSB/CW/RTTY modes Any mode FM/WFM/AM modes➁ Push F-1-F-3 to select a band stacking register Mode selectionOperating Mode Selection Quick band change functionRIT function Receive and TransmitFunctions for receive If shift functionPeak meter hold Noise blankerAGC time constant Preamp and attenuatorRF/SQL control priority RF gain and squelchSimple band scope SSB Filter PresettingOptional filter selection Filter ON/OFFNR Noise Reduction function Ceiver maintains the ON/OFF condition when pushing F-2NRANF Automatic Notch Filter function DMeter function Output power and mic gainFunctions for transmit VOX operation Speech compressorTuner Operation Manual TuningOptional AT-180 Automatic Antenna Tuner operation PTT tune function ➂ The Tuner light lights constantly when tuning is completeOptional AH-4AUTOMATIC Antenna Tuner operation AH-4 operationSplit lock function Split frequency operationQuick split function ➀ Select VFO a and set the frequency to 7.057 MHz/CW➄ Push and hold PTT to transmit release PTT to receive Repeater operation➂ Push F-3SCN to toggle tone scan operation on and OFF Tone squelch operationTone scan operation ➅ Communicate in the usual mannerFrequency Duplex Direction One-touch repeater functionAuto repeater function This function automatically activates the repeater setElec KEY Functions for CWConnections for CW CW operationCW pitch control CW reverse modeDElectronic CW keyer Quick SET Mode Setting the electronic keyerConnections for Afsk Functions for RttyConnections for Rtty FSK Rtty Afsk operation Presetting for RttyRtty FSK operation Data socket Adjusting the transmit signal output from the TNCPacket operation Connections for packetPlot measurement Measuring SWRSpot measurement Memory clearing Memory and Scan OperationMemory channels Memory channel selectionMemory/call programming Programming in VFO modeProgramming in memory mode Editing programming memory names Frequency transferringMemory names Calling up memory names➀ Select the S1 display Memo padsWriting frequencies and operating modes into memo pads Calling up a frequency from a memo padPreparation Scan typesPriority watch Programmed scan operationMemory scan operation Select memory scan operationData format Remote Jack CI-V InformationCI-V connection example VFO A=B Command TableGeneral SET ModeQuick set mode operation Initial set mode operationQ4 VOX Gain SSB/AM/FM only Quick set mode itemsQ3 VOX Delay SSB/AM/FM only Q2 MIC Gain SSB/AM/FM onlyQ5 Anti VOX SSB/AM/FM only Initial set mode items RF/SQL SQL/AUTO/RFSQL DUP HF duplex offset Quick Split quick split functionSplit Lock split lock SPL Offset split offsetScan Resume scan resume AM NB Noise blanker in AM modePWR on CHK Power on check Auto Rptr auto repeaterVsend SEL ACC socket output 29 9600 Mode Data socket speedTune Strt auto tuner start PTT Tune PTT tune functionCI-V TRN CI-V transceive LVL Spch S-level speechCI-V Addres CI-V address CI-V Baud CI-V data rateCleaning MaintenanceFuse replacement Memory backupPower Supply Receive Problem Possible Cause Solution TroubleshootingTransmit Display Scan Problem Possible Cause Solution Opening the transceiver case Optional INSTALLATIONS/SETTINGSIf filters DOperation InstallationPIN no Description Name AT-180 internal switch descriptionS2 S1 B a Bottom view Internal ViewsTop view Options SP-21EXTERNAL Speaker SP-7EXTERNAL SpeakerSP-10EXTERNAL Speaker SP-12EXTERNAL Speaker SP-20EXTERNAL SpeakerSpecifications Indication Description No. Indication + power onPower OFF then on to exit initial set mode Menu GuideMenu Display SSB/AM/FM mode CW mode Rtty modeMode Display For 2 secCount on us