Icom iC-706MKTMG manual Optional INSTALLATIONS/SETTINGS, Opening the transceiver case

Page 62

10 OPTIONAL INSTALLATIONS/SETTINGS

Opening the transceiver case

To remove the transceiver case unscrew the 10 screws (5 in the top panel and 5 in the bottom panel) as shown in the diagram below.

UT-102VOICE SYNTHESIZER UNIT

The UT-102 announces the accessed band’s fre- quency, mode, etc. (S-meter level can also be announced—p. 55) in a clear, electronically generat- ed voice, in English (or Japanese).

Remove the top cover as shown above.

Connect the UT-102 as shown in the diagram at

right (label side up).

Replace the top cover.

Caution: Disconnect the DC power cable from the transceiver before performing any work on the transceiver.

UT-102

59

Image 62
Contents I706MKG Precautions Word Definition RwarningTable of Contents 0MAIN Dial Tension Latch Panel DescriptionFront panel 2LOCK Switch Lock @2PREAMP/ATTENUATOR Switch P.AMP/ATTFunction switches BREAK-IN p VOX Function pSpeech Compressor p Function pRear and side panels ACC Socket When connecting the ACC conversion cable OPC-599ACC PIN # Name Description Specifications Color 4DSP Indicators 1DOT Matrix Indicators3FUNCTION Indicators Function displayMicrophone Connector ➊UP/DOWN Switches UP/DN ➋LOCK Switch Lock➌PTT Switch PTT HM-103 Schematic DiagramUnpacking Installation and ConnectionsPL-259 Connector Installation Example GroundingStand InstallationSingle body mounting Front panel separationRequired connections Rtty TerminalAdvanced connections Connecting a NON-ICOM DC Power Supply Power supply connectionsConnecting the PS-85 DC Power Supply Connecting a NON-ICOMConnecting the IC-PW1 Connecting the AH-4Connecting the AT-180 External antenna tuners and linear amplifierInitial settings Frequency SettingWhen first applying power CPU resetting Power OFFVFO description VFO ModeMemory Mode pgs VFOHz and 10 Hz tuning steps Frequency settingProgrammable tuning steps Band selectionSSB/CW/RTTY modes Any mode FM/WFM/AM modes MHz quick tuning stepTS Switch Flow Chart Sub dial functionQuick band change function Mode selectionOperating Mode Selection ➁ Push F-1-F-3 to select a band stacking registerIf shift function Receive and TransmitFunctions for receive RIT functionPreamp and attenuator Noise blankerAGC time constant Peak meter holdRF/SQL control priority RF gain and squelchSimple band scope Filter ON/OFF Filter PresettingOptional filter selection SSBNR Noise Reduction function Ceiver maintains the ON/OFF condition when pushing F-2NRANF Automatic Notch Filter function DMeter function Output power and mic gainFunctions for transmit Speech compressor VOX operationTuner Operation Manual TuningOptional AT-180 Automatic Antenna Tuner operation AH-4 operation ➂ The Tuner light lights constantly when tuning is completeOptional AH-4AUTOMATIC Antenna Tuner operation PTT tune function➀ Select VFO a and set the frequency to 7.057 MHz/CW Split frequency operationQuick split function Split lock functionRepeater operation ➄ Push and hold PTT to transmit release PTT to receive➅ Communicate in the usual manner Tone squelch operationTone scan operation ➂ Push F-3SCN to toggle tone scan operation on and OFFThis function automatically activates the repeater set One-touch repeater functionAuto repeater function Frequency Duplex DirectionCW operation Functions for CWConnections for CW Elec KEYSetting the electronic keyer CW reverse modeDElectronic CW keyer Quick SET Mode CW pitch controlConnections for Afsk Functions for RttyConnections for Rtty FSK Rtty Afsk operation Presetting for RttyRtty FSK operation Connections for packet Adjusting the transmit signal output from the TNCPacket operation Data socketPlot measurement Measuring SWRSpot measurement Memory channel selection Memory and Scan OperationMemory channels Memory clearingMemory/call programming Programming in VFO modeProgramming in memory mode Calling up memory names Frequency transferringMemory names Editing programming memory namesCalling up a frequency from a memo pad Memo padsWriting frequencies and operating modes into memo pads ➀ Select the S1 displayScan types PreparationSelect memory scan operation Programmed scan operationMemory scan operation Priority watchData format Remote Jack CI-V InformationCI-V connection example Command Table VFO A=BInitial set mode operation SET ModeQuick set mode operation GeneralQ2 MIC Gain SSB/AM/FM only Quick set mode itemsQ3 VOX Delay SSB/AM/FM only Q4 VOX Gain SSB/AM/FM onlyQ5 Anti VOX SSB/AM/FM only Initial set mode items RF/SQL SQL/AUTO/RFSQL SPL Offset split offset Quick Split quick split functionSplit Lock split lock DUP HF duplex offsetAuto Rptr auto repeater AM NB Noise blanker in AM modePWR on CHK Power on check Scan Resume scan resumePTT Tune PTT tune function 29 9600 Mode Data socket speedTune Strt auto tuner start Vsend SEL ACC socket outputCI-V Baud CI-V data rate LVL Spch S-level speechCI-V Addres CI-V address CI-V TRN CI-V transceiveMemory backup MaintenanceFuse replacement CleaningTroubleshooting Power Supply Receive Problem Possible Cause SolutionTransmit Display Scan Problem Possible Cause Solution Optional INSTALLATIONS/SETTINGS Opening the transceiver caseIf filters Installation DOperationPIN no Description Name AT-180 internal switch descriptionS2 S1 B a Bottom view Internal ViewsTop view Options SP-20EXTERNAL Speaker SP-7EXTERNAL SpeakerSP-10EXTERNAL Speaker SP-12EXTERNAL Speaker SP-21EXTERNAL SpeakerSpecifications Menu Guide + power onPower OFF then on to exit initial set mode Indication Description No. IndicationFor 2 sec SSB/AM/FM mode CW mode Rtty modeMode Display Menu DisplayCount on us