7 SET MODE

33S-LVL SPCH (S-level speech)

When an optional UT-102 SPEECH SYNTHESIZER UNIT

is installed, the synthesizer can be set to read out the frequency/mode only, or both the frequency/mode and S-meter level.

Voice synthesizer reads out

Voice synthesizer reads out

both the frequency/mode

the frequency/mode only.

and S-meter level (default).

 

34CI-V ADDRES (CI-V address)

To distinguish equipment, each CI-V transceiver has its own Icom standard address in hexadecimal code. The IC-706MKIIG’s address is 4EH.

When 2 or more IC-706MKIIG’s are connected to an optional CT-17 CI-V LEVEL CONVERTER, rotate the main dial to select a different address for each IC- 706MKIIG in the range 01H to 7FH.

Address set to 58H

Address set to 7FH.

(default).

 

35CI-V BAUD (CI-V data rate)

This item sets the data transfer rate. When “Auto” is selected, the baud rate is automatically set according to the connected controller or remote controller.

Auto baud rate

19200 bps

(default)

 

36CI-V TRN (CI-V transceive)

Transceive operation is possible with the IC- 706MKIIG connected to other Icom HF transceivers or receivers. When “on” is selected, changing the frequency, operating mode, etc. on the IC-706MKIIG automatically changes those of connected trans- ceivers (or receivers) and vice versa.

Transceive ON

Transceive OFF

(default)

 

37CI-V 731 (CI-V operating fre- quency data length)

When connecting the IC-706MKIIG to the IC-735 for transceive operation, you must change the operating frequency data length to 4 bytes.

This item MUST be set to “on” only when operating trans- ceiver with the IC-735.

Frequency data set to

Frequency data set to

5 bytes (default).

4 bytes.

55

Image 58
Contents I706MKG Precautions Word Definition RwarningTable of Contents Front panel Panel Description0MAIN Dial Tension Latch 2LOCK Switch Lock @2PREAMP/ATTENUATOR Switch P.AMP/ATTFunction switches BREAK-IN p VOX Function pSpeech Compressor p Function pRear and side panels ACC PIN # Name Description Specifications Color When connecting the ACC conversion cable OPC-599ACC Socket 4DSP Indicators 1DOT Matrix Indicators3FUNCTION Indicators Function displayMicrophone Connector ➊UP/DOWN Switches UP/DN ➋LOCK Switch Lock➌PTT Switch PTT HM-103 Schematic DiagramUnpacking Installation and ConnectionsPL-259 Connector Installation Example GroundingStand InstallationSingle body mounting Front panel separationRequired connections Rtty TerminalAdvanced connections Connecting a NON-ICOM DC Power Supply Power supply connectionsConnecting the PS-85 DC Power Supply Connecting a NON-ICOMConnecting the IC-PW1 Connecting the AH-4Connecting the AT-180 External antenna tuners and linear amplifierInitial settings Frequency SettingWhen first applying power CPU resetting Power OFFVFO description VFO ModeMemory Mode pgs VFOHz and 10 Hz tuning steps Frequency settingProgrammable tuning steps Band selectionSSB/CW/RTTY modes Any mode FM/WFM/AM modes MHz quick tuning stepTS Switch Flow Chart Sub dial functionQuick band change function Mode selectionOperating Mode Selection ➁ Push F-1-F-3 to select a band stacking registerIf shift function Receive and TransmitFunctions for receive RIT functionPreamp and attenuator Noise blankerAGC time constant Peak meter holdSimple band scope RF gain and squelchRF/SQL control priority Filter ON/OFF Filter PresettingOptional filter selection SSBANF Automatic Notch Filter function Ceiver maintains the ON/OFF condition when pushing F-2NRNR Noise Reduction function Functions for transmit Output power and mic gainDMeter function Speech compressor VOX operationOptional AT-180 Automatic Antenna Tuner operation Manual TuningTuner Operation AH-4 operation ➂ The Tuner light lights constantly when tuning is completeOptional AH-4AUTOMATIC Antenna Tuner operation PTT tune function➀ Select VFO a and set the frequency to 7.057 MHz/CW Split frequency operationQuick split function Split lock functionRepeater operation ➄ Push and hold PTT to transmit release PTT to receive➅ Communicate in the usual manner Tone squelch operationTone scan operation ➂ Push F-3SCN to toggle tone scan operation on and OFFThis function automatically activates the repeater set One-touch repeater functionAuto repeater function Frequency Duplex DirectionCW operation Functions for CWConnections for CW Elec KEYSetting the electronic keyer CW reverse modeDElectronic CW keyer Quick SET Mode CW pitch controlConnections for Rtty FSK Functions for RttyConnections for Afsk Rtty FSK operation Presetting for RttyRtty Afsk operation Connections for packet Adjusting the transmit signal output from the TNCPacket operation Data socketSpot measurement Measuring SWRPlot measurement Memory channel selection Memory and Scan OperationMemory channels Memory clearingProgramming in memory mode Programming in VFO modeMemory/call programming Calling up memory names Frequency transferringMemory names Editing programming memory namesCalling up a frequency from a memo pad Memo padsWriting frequencies and operating modes into memo pads ➀ Select the S1 displayScan types PreparationSelect memory scan operation Programmed scan operationMemory scan operation Priority watchCI-V connection example Remote Jack CI-V InformationData format Command Table VFO A=BInitial set mode operation SET ModeQuick set mode operation GeneralQ2 MIC Gain SSB/AM/FM only Quick set mode itemsQ3 VOX Delay SSB/AM/FM only Q4 VOX Gain SSB/AM/FM onlyQ5 Anti VOX SSB/AM/FM only Initial set mode items RF/SQL SQL/AUTO/RFSQL SPL Offset split offset Quick Split quick split functionSplit Lock split lock DUP HF duplex offsetAuto Rptr auto repeater AM NB Noise blanker in AM modePWR on CHK Power on check Scan Resume scan resumePTT Tune PTT tune function 29 9600 Mode Data socket speedTune Strt auto tuner start Vsend SEL ACC socket outputCI-V Baud CI-V data rate LVL Spch S-level speechCI-V Addres CI-V address CI-V TRN CI-V transceiveMemory backup MaintenanceFuse replacement CleaningTroubleshooting Power Supply Receive Problem Possible Cause SolutionTransmit Display Scan Problem Possible Cause Solution Optional INSTALLATIONS/SETTINGS Opening the transceiver caseIf filters Installation DOperationS2 S1 B a AT-180 internal switch descriptionPIN no Description Name Top view Internal ViewsBottom view Options SP-20EXTERNAL Speaker SP-7EXTERNAL SpeakerSP-10EXTERNAL Speaker SP-12EXTERNAL Speaker SP-21EXTERNAL SpeakerSpecifications Menu Guide + power onPower OFF then on to exit initial set mode Indication Description No. IndicationFor 2 sec SSB/AM/FM mode CW mode Rtty modeMode Display Menu DisplayCount on us