Icom iC-706MKTMG manual Menu Guide, + power on, Power OFF then on to exit initial set mode, Lock

Page 70

14 MENU GUIDE

LOCK

+ power ON

 

Power OFF then ON to exit initial set mode.

 

 

 

 

 

 

Initial set mode

 

 

 

 

MENU

 

 

 

 

 

 

 

 

No.

Indication

Description

No. Indication

Description

 

 

 

 

 

 

 

 

 

1

MODE SELECT

Mode availability

20

AUTO RPTR

Auto repeater function

 

2

BEEP

Confirmation beeps

21

SCAN RESUME

Scan resume condition

Y

3

BAND BEEP

Band edge beeps

22

SCAN SPEED

Scanning speed

4

BACK LIGHT

Display backlighting

23

U/D SPEED

[UP]/[DN] speed

 

 

5

KEY LIGHT

Key backlighting

24

AM NB

AM noise blanker

 

6

AUTO OFF

Auto power OFF function

25

PAD CH

No. of memory pads

 

7

RF/SQL

RF gain/squelch control

26

PWR ON CHK

Power ON check function

 

8

SUB DIAL

Sub dial RIT function

27

A-TUNE STRT

Auto tune start function

 

9

OPT.FIL 1

Optional filter 1

28

PTT TUNE

PTT tune function

 

10

OPT.FIL 2

Optional filter 2

29

9600 MODE

Packet data speed

 

11

PEAK HOLD

Meter peak function

30

VSEND SEL

ACC output selection

 

12

QUICK SPLIT

Quick split function

31

SPEECH LANG

Speech synthesizer lang.

 

13

SPLIT LOCK

Split lock function

32

SPEECH SPD

Speech synthesizer speed

 

14

SPL OFFSET

Quick split offset

33

S-LVL SPC

Speech synthesizer S-meter

Z

15

DUP HF

Quick split offset (HF)

34

CI-V ADDRES

CI-V address assignment

16

DUP 50M

Quick split offset (50 MHz)

35

CI-V BAUD

Data transfer rate

 

 

17

DUP 144M

Quick split offset (144 MHz)

36

CI-V TRN

CI-V transceive

 

18

DUP 430M

Quick split offset (430 MHz)

37

CI-V 731

CI-V 731

MENU

19

1TOUCH RPTR

One touch repeater

 

 

 

 

 

 

 

 

 

 

 

67

Image 70
Contents I706MKG Precautions Word Definition RwarningTable of Contents Front panel Panel Description0MAIN Dial Tension Latch 2LOCK Switch Lock @2PREAMP/ATTENUATOR Switch P.AMP/ATTFunction switches BREAK-IN p VOX Function pSpeech Compressor p Function pRear and side panels ACC PIN # Name Description Specifications Color When connecting the ACC conversion cable OPC-599ACC Socket 4DSP Indicators 1DOT Matrix Indicators3FUNCTION Indicators Function displayMicrophone Connector ➊UP/DOWN Switches UP/DN ➋LOCK Switch Lock➌PTT Switch PTT HM-103 Schematic DiagramUnpacking Installation and ConnectionsPL-259 Connector Installation Example GroundingStand InstallationSingle body mounting Front panel separationRequired connections Rtty TerminalAdvanced connections Connecting a NON-ICOM DC Power Supply Power supply connectionsConnecting the PS-85 DC Power Supply Connecting a NON-ICOMConnecting the IC-PW1 Connecting the AH-4Connecting the AT-180 External antenna tuners and linear amplifierInitial settings Frequency SettingWhen first applying power CPU resetting Power OFFVFO description VFO ModeMemory Mode pgs VFOHz and 10 Hz tuning steps Frequency settingProgrammable tuning steps Band selectionSSB/CW/RTTY modes Any mode FM/WFM/AM modes MHz quick tuning stepTS Switch Flow Chart Sub dial functionQuick band change function Mode selectionOperating Mode Selection ➁ Push F-1-F-3 to select a band stacking registerIf shift function Receive and TransmitFunctions for receive RIT functionPreamp and attenuator Noise blankerAGC time constant Peak meter holdSimple band scope RF gain and squelchRF/SQL control priority Filter ON/OFF Filter PresettingOptional filter selection SSBANF Automatic Notch Filter function Ceiver maintains the ON/OFF condition when pushing F-2NRNR Noise Reduction function Functions for transmit Output power and mic gainDMeter function Speech compressor VOX operationOptional AT-180 Automatic Antenna Tuner operation Manual TuningTuner Operation AH-4 operation ➂ The Tuner light lights constantly when tuning is completeOptional AH-4AUTOMATIC Antenna Tuner operation PTT tune function➀ Select VFO a and set the frequency to 7.057 MHz/CW Split frequency operationQuick split function Split lock functionRepeater operation ➄ Push and hold PTT to transmit release PTT to receive➅ Communicate in the usual manner Tone squelch operationTone scan operation ➂ Push F-3SCN to toggle tone scan operation on and OFFThis function automatically activates the repeater set One-touch repeater functionAuto repeater function Frequency Duplex DirectionCW operation Functions for CWConnections for CW Elec KEYSetting the electronic keyer CW reverse modeDElectronic CW keyer Quick SET Mode CW pitch controlConnections for Rtty FSK Functions for RttyConnections for Afsk Rtty FSK operation Presetting for RttyRtty Afsk operation Connections for packet Adjusting the transmit signal output from the TNCPacket operation Data socketSpot measurement Measuring SWRPlot measurement Memory channel selection Memory and Scan OperationMemory channels Memory clearingProgramming in memory mode Programming in VFO modeMemory/call programming Calling up memory names Frequency transferringMemory names Editing programming memory namesCalling up a frequency from a memo pad Memo padsWriting frequencies and operating modes into memo pads ➀ Select the S1 displayScan types PreparationSelect memory scan operation Programmed scan operationMemory scan operation Priority watchCI-V connection example Remote Jack CI-V InformationData format Command Table VFO A=BInitial set mode operation SET ModeQuick set mode operation GeneralQ2 MIC Gain SSB/AM/FM only Quick set mode itemsQ3 VOX Delay SSB/AM/FM only Q4 VOX Gain SSB/AM/FM onlyQ5 Anti VOX SSB/AM/FM only Initial set mode items RF/SQL SQL/AUTO/RFSQL SPL Offset split offset Quick Split quick split functionSplit Lock split lock DUP HF duplex offsetAuto Rptr auto repeater AM NB Noise blanker in AM modePWR on CHK Power on check Scan Resume scan resumePTT Tune PTT tune function 29 9600 Mode Data socket speedTune Strt auto tuner start Vsend SEL ACC socket outputCI-V Baud CI-V data rate LVL Spch S-level speechCI-V Addres CI-V address CI-V TRN CI-V transceiveMemory backup MaintenanceFuse replacement CleaningTroubleshooting Power Supply Receive Problem Possible Cause SolutionTransmit Display Scan Problem Possible Cause Solution Optional INSTALLATIONS/SETTINGS Opening the transceiver caseIf filters Installation DOperationS2 S1 B a AT-180 internal switch descriptionPIN no Description Name Top view Internal ViewsBottom view Options SP-20EXTERNAL Speaker SP-7EXTERNAL SpeakerSP-10EXTERNAL Speaker SP-12EXTERNAL Speaker SP-21EXTERNAL SpeakerSpecifications Menu Guide + power onPower OFF then on to exit initial set mode Indication Description No. IndicationFor 2 sec SSB/AM/FM mode CW mode Rtty modeMode Display Menu DisplayCount on us