NOTES:
•Series recording may have a short pause (up to five sec- onds) when going from re- corder A to recorder B. How- ever, if you set CALL OUT in the Rear Terminal menu to WRNG•REMAIN, this delay is eliminated.
8.1.5 Series Recording
You can do series recording by connecting two or more TLR2168S VCRs together. When the tape in the first VCR reaches the end during recording, the tape in the second VCR automatically begins recording.
1.Set REC IN on the Rear Terminal menu to SERIES.
2.Set CALL OUT on the Rear Terminal menu to WRNG•TAPE END.
3.Set TAPE END on the First Time Set Up menu to REWIND.
•When set in the above configu- ration and the second VCR reaches the end of the tape, the first VCR automatically begins recording. Connect the line marked by [*1] in Figure 19 only if you want the first VCR to begin recording again. If not, do not connect it.
•If a problem occurs (for ex- ample, the motor malfunc- tions during recording) in the first VCR, the second VCR automatically begins record- ing.
•Series recording will not work during timer recording.
•When recording in series, set CALL OUT in the Rear Ter- minal menu to a mode other than WRNG.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| [*1] |
SET | RST | REC | GND | ALM | MODE | CLK | CALL | SET | RST | REC | GND | ALM | MODE | CLK | CALL |
| IN |
|
|
|
| OUT |
|
| IN |
|
|
|
| OUT |
|
Figure 19. Connecting VCRs in Series
8.1.6 One-Shot/Interval Recording
You can do
1.Press the REC/PLAY MODE button to set the recording mode to 0H.
2.Set the number of fields in ONESHOT•FIELD in the Recording Set Up menu.
3.For
For interval recording, choose the interval time from 10S (seconds) to 3M (minutes) in ONESHOT•INTERVAL.
4.Press the REC button.
5.To start
34 | Pelco Manual C649M (7/99) |