Pelco c649m operation manual Day and Time Display Modes

Page 27

12 3 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-01-97

00:00:00

 

 

 

A0001

 

 

 

 

 

 

 

 

 

 

 

Figure 16. Display Mode 1

12 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-01-97

 

WED

 

A0001

 

 

 

 

 

 

 

 

 

 

 

00:00:00

 

L18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45 6

Figure 17. Display Mode 2

PB HEAD

Sets the heads for playback. When you turn the JOG dial to the

SELECT

right, the display switches in the following order: NORMAL, L/

 

L (left/left), R/R (right/right), AUTO, NORMAL. The default is

 

NORMAL.

 

The VCR has two pairs of SP (standard play) heads. Some

 

VCRs make time-lapse recordings using same-azimuth heads,

 

which are not VHS compatible. Playback of such tapes with the

 

NORMAL setting will have picture/noise with a 30 Hz flicker, or

 

just noise. For proper playback, adjust the setting to AUTO, or

 

set to L/L or R/R. One setting will give normal play. After playing

 

a tape with L/L or R/R settings, return the setting to NORMAL.

BUZZER

Sets the conditions for which the buzzer sounds. The default is

 

WRNG.

 

• WRNG – The buzzer sounds when there is any malfunc-

 

tion in the VCR.

 

• WRNG•TAPE END – The buzzer sounds when there is

 

any malfunction in the VCR or at the tape end.

 

• WRNG•REMAIN – The buzzer sounds when there is any

 

malfunction in the VCR or when the tape (T-120 or T-160)

 

has about three minutes left in 2H mode.

 

• OFF – The buzzer does not sound.

TIME DATE

Sets the time, date, and Daylight Savings setting. Section

ADJUST

6.10.1 provides an explanation while Section 6.10.2 provides a

 

procedure.

6.10.1 Day and Time Display Modes

DISPLAY MODE 1

1.Month-Day-Year

2.Hour:Minute:Second

3.Daylight Savings Time symbol or power failure symbol

4.Alarm recording number

A 24-hour display is used: 00:00 indicates midnight; 12:00, noon; and 15:00, 3 p.m.

An alarm recording number is displayed during alarm recording.

DISPLAY MODE 2

1.Month-Day-Year

2.Day of the week

3.Alarm recording number

4.Hour:Minute:Second

5.Daylight Savings Time symbol or power failure symbol

6.Recording mode

A 24-hour display is used: 00:00 indicates midnight; 12:00, noon; and 15:00, 3 p.m.

The day of the week is automatically set.

An alarm recording number is displayed during alarm recording.

Pelco Manual C649M (7/99)

27

Image 27 Contents
TLR2168S Contents Locating the Start of Alarm Recordings Timer RecordingAlarm Recording Recording After a Power Failure Playback Playback ProcedureManual # Date Comments List of IllustrationsList of Tables Revision HistoryAvertissement GeneralSAFEGUARDS, WARNINGS, CAUTION, and Care Power Cord Protection CleaningAccessories Power SourcesCare Of Video Cassette Tape Regulatory NoticesInformation Unpacking InstructionsTLR2168S Features and Functions OverviewIntroduction to TIME-LAPSE Recorders Pelco Manual C649M 7/99 Quick Start Basic StartAdditional Items Securing the VCR Controls InstallationPRE-INSTALLATION Cautions InstallationAudio Monitor MIC Audio Video OUTMX4000 Genex Series Multiplexer Connecting the VCR to a MultiplexerFor Alarm Recording a lines in Figure TIME-LAPSE VCR Coaxial CableFront Panel ControlsFluorescent Display Rear Panel This page intentionally left blank General Programming Instructions ProgrammingMain Menu Display Quick Guide to TLR2168S Menu StructureBackground Color Blue Back Display Menu 6.4.1 Display ModeMain Menu Time Date SizeDirection Time Date Search MenuTime DateREC Timer Program MenuRecording SET UP Menu START/ENDRear Terminal Menu REC Maintenance MenuMode OUT Clock OUTFirst Time Set Up Menu First Time SET UP MenuDay and Time Display Modes Set the Day and Time OFF Preventing Accidental Erasure LOADING/UNLOADING/PROTECTING the Tape CassetteLoading UnloadingManual Recording RecordingRepeat Recording Recording ModeRecord Check Function Audio RecordingRecording Number of Repeat Tape Uses Time Mode Number of Tape Uses Repeat Recording TimesRecommended Number of Tape Uses One-Shot/Interval Recording Series RecordingREC REC REC Synchronous RecordingSync VCRVCR Timer RecordingProgramming Procedure Special DW SettingsAvoid Mistakes When Using the Timer Alarm RecordingSymptom Fault Action Alarm Recording Connection External Time Clock Adjustment1st VCR 2nd VCR Programming For Alarm Recording Emergency Recording Alarm Record Time DisplayReset The Alarm Recording List Recording After a Power FailurePlayback Playback ProcedureSpecial Effects Playback Playback ModeAudio Playback End Of TapeDirect Shuttle Ring Shuttle RingIndex Search Locating the Start of Alarm RecordingsStill Picture Frame-by-Frame PlaybackAdjustment During Playback 9.4.1 Tracking Adjustment Skip SearchIf Noise Appears Sharp Picture Quality AdjustmentVertical Adjustment When the Picture Is VibratingCounter Additional Functions and FeaturesMemory Backup in Case of Power Failure Power Failure Time DisplayElapsed Time Display Testing Initial System TestingRegular System Testing Indication TroubleshootingSELF-DIAGNOSTIC Function and Warning Display Fluorescent Monitor Cause Remedy To Turn OFFSymptom Remedy Before Calling for ServiceSpecifications ALM/CALL/MODE SET/RST/REC CLKRecord Record Time Field Picture Tape Drive Audio Recording GND Pelco Manual C649M 7/99 Pelco Manual C649M 7/99 Warranty and Return Information WarrantyReturns
Related manuals
Manual 56 pages 34.38 Kb