CLOCK OUT | Sets the number of frames or fields to record (depending on the | |
| recording mode) at the CLOCK OUT terminal. The default is | |
| REC. | |
| 1. | First, set the recording mode for the CLOCK OUT pulse |
|
| output in the Rear Terminal menu. |
|
| • REC – When recording in any mode. |
|
| • |
|
| (L18H, L24H, 48H, 72H, 96H, 120H, 168H, or 0H). |
| 2. | Second, select the frequency interval by turning the |
|
| SHUTTLE ring. When you turn the JOG dial, the display |
|
| switches in the following order: 1, 2, 3, 4, 5, 10, 15, 20, |
|
| 25, 30, 50, 60, F (field), 1. The numbers from 1 to 60 |
|
| indicate the number of frames in 2H or 6H recording mode |
|
| or the number of fields in |
|
| frame consists of two fields. One field is selected when it |
|
| is set to “F” (field). |
MODE OUT | Sets the state in which the signal output at the MODE OUT | |
| terminal is switched to active. When you turn the JOG dial, the | |
| display switches in the following order: REC (recording), PLAY | |
| (playback), POWER (power on), TAPE IN (tape inserted), | |
| TAPE REMAIN (three minutes in 2H mode before the tape | |
| ends), CLOCK ADJ (output the signal for one second when the | |
| clock indicates 00[min]:00[sec]), REC. The default is REC. | |
REC IN | Sets the REC IN terminal’s operation mode. The default is | |
| SERIES. |
•SERIES – Recording starts when the REC IN terminal is
•
•SYNC REC – The video signals from 3 or 13 cameras can be recorded separately by connecting a switcher. (Synchronous recording is available when recording in L18H or L24H mode.) Synchronous recording is explained (and the procedure listed) in Section 8.1.7.
6.9MAINTENANCE MENU
<MAINTENANCE>
POWER LOSS LIST
ALARM LIST
ALL MENU INITIALIZE
POWER LOSS LIST CLEAR
ALARM LIST CLEAR
<REPEAT REC TIMES> | 0 |
<ELAPSED TIME> | 0H |
Figure 14. Maintenance Menu
POWER LOSS To display the power loss list, turn the JOG dial to select
LISTPOWER LOSS LIST. Turn the SHUTTLE ring to the right to display the list. Power failure start times are stored in memory, so you can confirm when they occurred. Up to three power failure start times will be displayed. If there were more than three, the first and last two power failure start times will be displayed.
ALARM LIST To display the alarm list, turn the JOG dial to select ALARM LIST. Turn the SHUTTLE ring to the right to display the list. Alarm record start times are stored in memory, so you can confirm when they occurred. Up to three alarm record start times will be displayed. If there were more than three, the first and last two alarm record start times will be displayed.