13.0 SPECIFICATIONS

Power Source:

Power Consumption:

Rating:

ALM/CALL/MODE

SET/RST/REC

CLK

Tape Format:

Television System:

Video Recording System:

Luminance Signal:

Color Signal:

Audio Track: Tape Speed and Recording Time (with T-120 cassette):

100-230 VAC, 50/60 Hz. (The included power cord is used for 120 VAC, 60 Hz)

Approximately 20 watts

Active: “Low” level, maximum current 50 mA (+5 VDC)/10 mA (+24 VDC)

Non-active: Open, maximum voltage +24 VDC

Active: When terminals are short-circuited or “Low” level voltage applied

Non-active: Open, max. Voltage +17 VDC

Recording: A pulse of the frequency division ratio selected in REAR TERMINAL menu

S-VHS/VHS 1/2" width high-density video cassette tape

525 lines, 60 field NTSC-type color system

2 rotary heads, azimuth helical scanning system

Frequency modulation recording

Low frequency conversion, sub-carrier phase shift recording

1 track

Record

Record Time

Record Time

Field (Picture)

Tape Drive

Audio Recording

Mode

(T-120/ST-120 Tape)

(T-160/ST-160 Tape)

Recording Rate

Mode

Capability

 

 

 

 

 

 

2H

2 Hrs.

2 Hrs.40 Mins.

60 Fields/Sec

Continuous

Yes

 

 

 

 

 

 

6H

6 Hrs.

8 Hrs.

60 Fields/Sec

Continuous

Yes

 

 

 

 

 

 

L18H

18 Hrs.

24 Hrs.

20 Fields/Sec

Continuous(Slow)

Yes

L24H

26 Hrs.

34 Hrs.40 Mins.

4.6 Fields/Sec

Continuous(Slow)

Yes

 

 

 

 

 

 

48H (SP)

50 Hrs.

Not Recommended

2.4 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

48H (EP)

54 Hrs.

Not Recommended

6.7 Fields/Sec

Time-lapse

No

72H (SP)

74 Hrs.

Not Recommended

1.6 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

72H (EP)

78 Hrs.

Not Recommended

4.6 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

96H (SP)

98 Hrs.

Not Recommended

1.2 Fields/Sec

Time-lapse

No

96H (EP)

102 Hrs.

Not Recommended

3.5 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

120H (SP)

122 Hrs.

Not Recommended

0.98 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

120H (SP)

126 Hrs.

Not Recommended

2.9 Fields/Sec

Time-lapse

No

168H (SP)

170 Hrs.

Not Recommended

0.70 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

168H (EP)

174 Hrs.

Not Recommended

2.1 Fields/Sec

Time-lapse

No

 

 

 

 

 

 

0H (one-shot)

1199Hrs.*

Not Recommended

0.10 Fields/Sec

Interval Time-lapse

No

 

 

 

 

 

 

* Programmed for: 1 Field-per-Shot @ 10-Second Interval Rate

52

Pelco Manual C649M (7/99)

Image 52
Contents TLR2168S Contents Timer Recording Alarm RecordingRecording After a Power Failure Playback Playback Procedure Locating the Start of Alarm RecordingsList of Illustrations List of TablesRevision History Manual # Date CommentsGeneral AvertissementSAFEGUARDS, WARNINGS, CAUTION, and Care Cleaning AccessoriesPower Sources Power Cord ProtectionRegulatory Notices InformationUnpacking Instructions Care Of Video Cassette TapeOverview TLR2168S Features and FunctionsIntroduction to TIME-LAPSE Recorders Pelco Manual C649M 7/99 Basic Start Quick StartAdditional Items Installation PRE-INSTALLATION CautionsInstallation Securing the VCR ControlsMIC Audio Video OUT Audio MonitorConnecting the VCR to a Multiplexer For Alarm Recording a lines in FigureTIME-LAPSE VCR Coaxial Cable MX4000 Genex Series MultiplexerControls Front PanelFluorescent Display Rear Panel This page intentionally left blank Programming General Programming InstructionsQuick Guide to TLR2168S Menu Structure Main Menu DisplayDisplay Menu 6.4.1 Display Mode Main MenuTime Date Size Background Color Blue BackTime Date Search Menu TimeDate DirectionTimer Program Menu Recording SET UP MenuSTART/END RECRear Terminal Menu Maintenance Menu Mode OUTClock OUT RECFirst Time SET UP Menu First Time Set Up MenuDay and Time Display Modes Set the Day and Time OFF LOADING/UNLOADING/PROTECTING the Tape Cassette LoadingUnloading Preventing Accidental ErasureRecording Manual RecordingRecording Mode Record Check FunctionAudio Recording Repeat RecordingNumber of Tape Uses Repeat Recording Times Recording Number of Repeat Tape Uses Time ModeRecommended Number of Tape Uses Series Recording One-Shot/Interval RecordingSynchronous Recording SyncVCR REC REC RECTimer Recording Programming ProcedureSpecial DW Settings VCRAlarm Recording Avoid Mistakes When Using the TimerSymptom Fault Action External Time Clock Adjustment Alarm Recording Connection1st VCR 2nd VCR Programming For Alarm Recording Alarm Record Time Display Reset The Alarm Recording ListRecording After a Power Failure Emergency RecordingPlayback Procedure PlaybackPlayback Mode Audio PlaybackEnd Of Tape Special Effects PlaybackShuttle Ring Direct Shuttle RingLocating the Start of Alarm Recordings Still PictureFrame-by-Frame Playback Index SearchSkip Search Adjustment During Playback 9.4.1 Tracking AdjustmentIf Noise Appears Picture Quality Adjustment Vertical AdjustmentWhen the Picture Is Vibrating SharpAdditional Functions and Features Memory Backup in Case of Power FailurePower Failure Time Display CounterElapsed Time Display Initial System Testing TestingRegular System Testing Troubleshooting SELF-DIAGNOSTIC Function and Warning DisplayFluorescent Monitor Cause Remedy To Turn OFF IndicationBefore Calling for Service Symptom RemedyALM/CALL/MODE SET/RST/REC CLK SpecificationsRecord Record Time Field Picture Tape Drive Audio Recording GND Pelco Manual C649M 7/99 Pelco Manual C649M 7/99 Warranty Warranty and Return InformationReturns