Pelco c649m operation manual Gnd

Page 53

Fast Forward/Rewind Time:

Approx. 140 sec. with T-120 cassette

Horizontal Resolution:

More than 240 lines (VHS mode)

 

More than 400 lines (S-VHS, S-VHS ET modes)

Audio Frequency Response:

70 Hz-7 kHz (2H mode)

Signal-to-Noise Ratio:

Video: better than 42 dB

 

Audio: better than 43 dB

Alarm Recording Time:

Timed: 15 sec/30 sec/45 sec/1 min./2 min./5 min./

 

10 min.

 

Manual 1: Until the alarm reset switch is switched on.

 

Manual 2: Until the alarm set switch is switched off.

Display Format

(Month)-(Day)-(Year) (Day of week)

 

(Hour) : (Minute) : (Second) (Recording mode)

 

or

 

(Month)-(Day)-(Year) (Hour) : (Minute) : (Second)

Display Position:

In any position

Timer Program:

8 programs; Daily start and stop time for one week

Memory Backup:

Lasts 31 days

Elapsed Time Indicator:

Maximum of 89,999 hours

Heads

 

Video:

6 rotary single crystal heads

Audio/Control:

1 stationary head

Erase:

1 full-track head

Motors:

3 motors-drum/capstan direct drive system

Video Input:

0.5~2.0 Vp-p, 75-ohm S-connector (Y signal)

 

and BNC plug;

 

0.15~0.6 Vp-p, 75-ohm S-connector (C signal)

Audio Input:

-8 dBs, 50k ohms, RCA plug

Microphone Input:

-67 dBs, 600 ohms, mini mic jack

Video Output:

1.0 Vp-p, 75-ohm S-connector (Y signal)

 

and BNC plug;

 

0.3 Vp-p, 75-ohm S-connector (C signal)

Audio Output:

-6 dBs, 1k ohms, RCA plug

Connectors

 

SET Input:

Screw terminal for starting alarm recording

RST Input:

Screw terminal for finishing alarm recording or for

 

adjusting on-screen clock

REC Input:

Screw terminal for starting/finishing recording or for

 

series recording or for synchronous recording

GND:

Screw terminal for ground

ALM Output:

Screw terminal for output while alarm recording is

 

under way

CLK Output:

Screw terminal to command camera switching

MODE Output:

Screw terminal for indication of VCR selected mode

CALL Output:

Screw terminal for external warning device or for

 

series recording

REMOTE Jack:

Jack for connecting the remote control unit

Operating Temperature:

41°F-104°F (5°C to 40°C)

Relative Humidity:

Maximum 80%

Dimensions:

3.7"H x 16.7"W x 12.4"D (Jog dial included)

 

(9.3 x 42.5 x 31.5 cm)

Weight:

10 lb (4.5 kg)

(Design and product specifications subject to change without notice.)

Pelco Manual C649M (7/99)

53

Image 53
Contents TLR2168S Contents Alarm Recording Timer RecordingRecording After a Power Failure Playback Playback Procedure Locating the Start of Alarm RecordingsList of Tables List of IllustrationsRevision History Manual # Date CommentsAvertissement GeneralSAFEGUARDS, WARNINGS, CAUTION, and Care Accessories CleaningPower Sources Power Cord ProtectionInformation Regulatory NoticesUnpacking Instructions Care Of Video Cassette TapeIntroduction to TIME-LAPSE Recorders TLR2168S Features and FunctionsOverview Pelco Manual C649M 7/99 Additional Items Quick StartBasic Start PRE-INSTALLATION Cautions InstallationInstallation Securing the VCR ControlsAudio Monitor MIC Audio Video OUTFor Alarm Recording a lines in Figure Connecting the VCR to a MultiplexerTIME-LAPSE VCR Coaxial Cable MX4000 Genex Series MultiplexerFront Panel ControlsFluorescent Display Rear Panel This page intentionally left blank General Programming Instructions ProgrammingMain Menu Display Quick Guide to TLR2168S Menu StructureMain Menu Display Menu 6.4.1 Display ModeTime Date Size Background Color Blue BackTime Time Date Search MenuDate DirectionRecording SET UP Menu Timer Program MenuSTART/END RECRear Terminal Menu Mode OUT Maintenance MenuClock OUT RECFirst Time Set Up Menu First Time SET UP MenuDay and Time Display Modes Set the Day and Time OFF Loading LOADING/UNLOADING/PROTECTING the Tape CassetteUnloading Preventing Accidental ErasureManual Recording RecordingRecord Check Function Recording ModeAudio Recording Repeat RecordingRecommended Number of Tape Uses Recording Number of Repeat Tape Uses Time ModeNumber of Tape Uses Repeat Recording Times One-Shot/Interval Recording Series RecordingSync Synchronous RecordingVCR REC REC RECProgramming Procedure Timer RecordingSpecial DW Settings VCRSymptom Fault Action Avoid Mistakes When Using the TimerAlarm Recording 1st VCR 2nd VCR Alarm Recording ConnectionExternal Time Clock Adjustment Programming For Alarm Recording Reset The Alarm Recording List Alarm Record Time DisplayRecording After a Power Failure Emergency RecordingPlayback Playback ProcedureAudio Playback Playback ModeEnd Of Tape Special Effects PlaybackDirect Shuttle Ring Shuttle RingStill Picture Locating the Start of Alarm RecordingsFrame-by-Frame Playback Index SearchIf Noise Appears Adjustment During Playback 9.4.1 Tracking AdjustmentSkip Search Vertical Adjustment Picture Quality AdjustmentWhen the Picture Is Vibrating SharpMemory Backup in Case of Power Failure Additional Functions and FeaturesPower Failure Time Display CounterElapsed Time Display Regular System Testing TestingInitial System Testing SELF-DIAGNOSTIC Function and Warning Display TroubleshootingFluorescent Monitor Cause Remedy To Turn OFF IndicationSymptom Remedy Before Calling for ServiceRecord Record Time Field Picture Tape Drive Audio Recording SpecificationsALM/CALL/MODE SET/RST/REC CLK GND Pelco Manual C649M 7/99 Pelco Manual C649M 7/99 Returns Warranty and Return InformationWarranty