Pelco c649m Emergency Recording, Alarm Record Time Display, Reset The Alarm Recording List

Page 40

<ALARM LIST>

0001 01 - 05 - 98 01 : 00

0002 01 - 07 - 98 21 : 10

0003 01 - 10 - 98 09 : 15

01-01-97 WED

00:00:00X L18

8.3.4 Emergency Recording

Emergency alarm recording can start when an alarm is triggered even if the VCR is stopped or is programmed for timer recording.

1.Turn the JOG dial to select EMERGENCY REC and turn the SHUTTLE ring to the right.

2.Turn the JOG dial to select ON for emergency recording, or OFF to disable it.

EMGCY lights up on the fluorescent display when EMERGENCY REC in the Re- cording Set Up menu is set to ON.

8.3.5 Alarm Record Time Display

When alarm recordings begin, the start times are stored in memory so you can confirm when they occurred. Select ALARM LIST in the Maintenance menu and the alarm list will be displayed.

Up to three alarm recording start times can be stored in memory. If there are more, then the first and last two will be displayed.

8.3.5.1 Reset The Alarm Recording List

1.Select ALARM LIST CLEAR in the Maintenance menu.

2.Turn the SHUTTLE ring to the right. ALARM LIST CLEAR will be displayed.

3.Turn the SHUTTLE ring to the left. The alarm list will be cleared.

8.4RECORDING AFTER A POWER FAILURE

If there is a power failure during recording and the power comes back on, the VCR will begin recording in the same record mode as before the power failure. After the power comes back on, an “X” will be displayed next to the present time for about a minute.

If there is a power failure during playback, the VCR will be in stop mode when the power comes back on.

40

Pelco Manual C649M (7/99)

Image 40
Contents TLR2168S Contents Timer Recording Alarm RecordingRecording After a Power Failure Playback Playback Procedure Locating the Start of Alarm RecordingsList of Illustrations List of TablesRevision History Manual # Date CommentsGeneral AvertissementSAFEGUARDS, WARNINGS, CAUTION, and Care Cleaning AccessoriesPower Sources Power Cord ProtectionRegulatory Notices InformationUnpacking Instructions Care Of Video Cassette TapeOverview TLR2168S Features and FunctionsIntroduction to TIME-LAPSE Recorders Pelco Manual C649M 7/99 Basic Start Quick StartAdditional Items Installation PRE-INSTALLATION CautionsInstallation Securing the VCR ControlsMIC Audio Video OUT Audio MonitorConnecting the VCR to a Multiplexer For Alarm Recording a lines in FigureTIME-LAPSE VCR Coaxial Cable MX4000 Genex Series MultiplexerControls Front PanelFluorescent Display Rear Panel This page intentionally left blank Programming General Programming InstructionsQuick Guide to TLR2168S Menu Structure Main Menu DisplayDisplay Menu 6.4.1 Display Mode Main MenuTime Date Size Background Color Blue BackTime Date Search Menu TimeDate DirectionTimer Program Menu Recording SET UP MenuSTART/END RECRear Terminal Menu Maintenance Menu Mode OUTClock OUT RECFirst Time SET UP Menu First Time Set Up MenuDay and Time Display Modes Set the Day and Time OFF LOADING/UNLOADING/PROTECTING the Tape Cassette LoadingUnloading Preventing Accidental ErasureRecording Manual RecordingRecording Mode Record Check FunctionAudio Recording Repeat RecordingNumber of Tape Uses Repeat Recording Times Recording Number of Repeat Tape Uses Time ModeRecommended Number of Tape Uses Series Recording One-Shot/Interval RecordingSynchronous Recording SyncVCR REC REC RECTimer Recording Programming ProcedureSpecial DW Settings VCRAlarm Recording Avoid Mistakes When Using the TimerSymptom Fault Action External Time Clock Adjustment Alarm Recording Connection1st VCR 2nd VCR Programming For Alarm Recording Alarm Record Time Display Reset The Alarm Recording ListRecording After a Power Failure Emergency RecordingPlayback Procedure PlaybackPlayback Mode Audio PlaybackEnd Of Tape Special Effects PlaybackShuttle Ring Direct Shuttle RingLocating the Start of Alarm Recordings Still PictureFrame-by-Frame Playback Index SearchSkip Search Adjustment During Playback 9.4.1 Tracking AdjustmentIf Noise Appears Picture Quality Adjustment Vertical AdjustmentWhen the Picture Is Vibrating SharpAdditional Functions and Features Memory Backup in Case of Power FailurePower Failure Time Display CounterElapsed Time Display Initial System Testing TestingRegular System Testing Troubleshooting SELF-DIAGNOSTIC Function and Warning DisplayFluorescent Monitor Cause Remedy To Turn OFF IndicationBefore Calling for Service Symptom RemedyALM/CALL/MODE SET/RST/REC CLK SpecificationsRecord Record Time Field Picture Tape Drive Audio Recording GND Pelco Manual C649M 7/99 Pelco Manual C649M 7/99 Warranty Warranty and Return InformationReturns