<MAIN MENU>
DISPLAY
TIME DATE SEARCH TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE FIRST TIME SET UP Use JOG to select, and ENTER.
Press DISPLAY to exit.
<RECORDING SET UP> | 2H |
ALARM REC MODE | |
ALARM REC DURATION | 1M |
EMERGENCY REC | OFF |
|
|
<RECORDING SET UP> | 2H |
ALARM REC MODE | |
ALARM REC DURATION | 1M |
EMERGENCY REC | OFF |
<RECORDING SET UP> | 2H |
ALARM REC MODE | |
ALARM REC DURATION | 1M |
EMERGENCY REC | ON |
NOTES:
•If an alarm input is received dur- ing alarm recording, a new alarm recording will start with the new input signal. If one alarm input signal is received within 15 sec- onds of another, the later alarm input signal will be ignored and a new alarm recording will not take place.
•Alarm recording will continue for the period set in the ALARM REC DURATION field, even if a timer recording has reached its end time.
•Alarm recording stops when the end of the tape is reached.
8.3.3 Programming For Alarm Recording
Alarm recording speeds up recording when the VCR is recording in one of the time- lapse modes. Alarm recording provides more pictures during the alarm. Emergency recording activates alarm recording even if the VCR is off, stopped, or in timer recording/standby. You should set the alarm recording mode in the Recording Set Up menu before using alarm recording.
1.Press the DISPLAY button to display the Main menu.
2.Turn the JOG dial to select RECORDING SET UP and turn the SHUTTLE ring to the right. The Recording Set Up menu will appear.
3.Turn the JOG dial to select ALARM REC MODE and turn the SHUTTLE ring to the right.
4.Turn the JOG dial to set the alarm recording mode (2H, 6H, L18H, L24H) and turn the SHUTTLE ring to the right.
5.Turn the JOG dial to select ALARM REC DURATION and turn the SHUTTLE ring to the right.
6.Turn the JOG dial to set the alarm recording duration from 15 seconds to 10 minutes, MAN1, or MAN2 (manual) and turn the SHUTTLE ring to the right.
•If ALARM REC DURATION is set to MAN1, alarm recording will continue until a signal is received at the RST (reset) IN terminal. If that signal is within the first 15 seconds of alarm recording, alarm recording will con- tinue for 15 seconds and then stop.
•If ALARM REC DURATION is set to MAN2, alarm recording will continue until the signal received at the SET IN (alarm input) terminal is removed. If that signal is removed within 15 seconds of the start of alarm recording, alarm recording will continue for 15 seconds and then stop.
•The internal time clock can be adjusted if a signal is applied to the RST (reset) IN terminal when ALARM REC DURATION is set to other than MAN1.
7.Turn the JOG dial to select EMERGENCY REC and turn the SHUTTLE ring to the right. Turn the JOG dial to select ON.
8.Press the DISPLAY button. The time display will appear.
•During alarm recording, the alarm recording count will be displayed auto- matically except when Display Mode 4 is selected.
•The alarm recording count display counts up to 9999 alarm recordings and then resets to 0000 and continues counting.
•When initializing the alarm recording list, the alarm recording count dis- play will be reset.
•The alarm indicator flashes during alarm recording and lights steadily when the alarm recording finishes.
•When the alarm recording finishes, the VCR resumes recording in the same mode as before the alarm recording.
•If you are programming on any of the menus and an alarm input signal is received at the SET IN (alarm input) terminal, alarm recording will begin and the menu being programmed will disappear from the screen.
Pelco Manual C649M (7/99) | 39 |