INVENTORY INFO
1.clear_inventory,b3:0/3 (toggle this to clear all inventory, you must also reset this bit after completion)
2.hopper_inventory,f25:0
3.hauloff_accumalated_length,f31:4
EXTRUDER SETPOINT INFO
1.entered_extruder_rpm_target,f13:12 (write desired rpm here)
2.extruder_rpm_target,f13:4
3.extruder_rpm_instant,f13:1 (write rpm value here if you are not using the extruder prox signal for the calculation, NOT FOR
HAULOFF SETPOINT INFO
1.entered_hauloff_speed_target,f18:13 (write desired line speed here)
2.hauloff_speed_target,f18:3
3.current_measured_hauloff_speed,f18:1
RECIPE SETPOINT INFO
1.entered_recipe_target,f19:1 (write desired recipe entry here such as lbs/hr,lbs/ft,lbs/ft2)
2.recipe_running_target,f19:0 (running target based on hopper mode)
3.recipe actual value,f19:4 (compare this to target for accuracy)
4.ext_wtp_target,f11:16 (lbs/hr or kgs/hr depending if the system is in imperial or metric)
5.ext_wtp_average,f11:3 (lbs/hr or kgs/hr depending if the system is in imperial or metric)
6.layflat,f19:3
STEADY FLAGS
1.system_stable,b50;2/5
2.extruder_rpm_stable,b50:1/14
3.extruder_wtp_stable,b50:2/0
4.hauloff_stable,b50:2/1
Alarm Number Explanation:
The alarms are given in individual bits and are reflected in the alarm number. The alarm number is only used to drive a
N26:0 Value | Alarm Description |
|
0= | NO ALARM |
|
1= | HOPPER LOW LEVEL |
|
2= | HOPPER OUT OF MATERIAL |
|
3= | HOPPER OVER FILLING ALARM |
|
4= | NO EXTRUDER RPM DETECTED |
|
5= | NO EXTRUDER FLOW DETECTED |
|
6= | HAULOFF DRIVE FAILURE |
|
7= | LOADCELL OVER MAX |
|
8= | PLC BATTER LOW Check PLC and Configure the GH Hopper | |
9= | PLC MODULE LOADED Turn Off Unit,Remove Module, then Configure the GH | |
Hopper |
|
|
10= | RELOAD TOO LONG |
|
11= | GRAVIMETRIC PERCENTAGE TOO LOW | Decrease Extrusion Rate |
| Chapter 7: Appendix | 58 of 60 |