Toshiba kV-9960A ON-SCREEN Functions, Date-Time Display, VCR display, Monitor screen

Page 17

ON-SCREEN FUNCTIONS

When the power is turned ON, the time and date modes are displayed on the monitor screen (live picture). On-screen displays are not available in the event of no video input signal.

Date-Time Display

VCR display

INTRODUCTION

8/28/97 THU 17:30:02SPA 2

1 Date

2 Day of the week

8/28/97 THU 17:30:02SPA 2

PREPARATION

3 Time

Monitor screen

1Date : Displayed with the month-day-year.

2Day of the week : Automatically set to the correct day of the week when the date is set.

3Time : Set to 24-hour cycle at factory.

It is possible to modify to 12-hour (AM/PM) cycle display.

4Playback/Recording Time : Playback or Recording time display

4

Playback/Recording time

SP : SP mode

Nothing : EP mode

On-Screen Position

 

8/28/97 THU

 

17:30:02SPA 2

8/28/97 THU

8/28/97 THU

17:30:02SPA 2

17:30:02SPA 2

17:30:02SPA 2

8/28/97 THU 17:30:02SPA 2

Press the LOCATION SELECT button to adjust the display to desirable position. The display moves in the direction shown by the arrows.

Press this button : To down

LOCATION SELECT

Press this button : To right

However, during the date-time display screen, pay attention to the following when setting the date and time display positions:

When the display is set to an end of the monitor screen as shown in the figure, synchronization instability or color flickering may occur in some monitor TVs.

PLAYBACK

OPERATION

NOTICE

16

Image 17
Contents Instruction Manual Please Read Important PrecautionsPower Sources Important Safety InstructionsRadiators, heat registers, stoves Unplug this product from the wallPower Lines AccessoriesWhen the power-supply cord or plug is damaged To restore the product to its normal operationTable of Contents FeaturesFront Panel Instructions in BriefTape Remain button Time Mode / SET + buttonsCassette Compartment Display buttonRear Panel Specification of Battery Word on the Exclusive 3N-100AAS Battery PackInstallation RemovalVCR Display FF button REW buttonPress to start play back Connection with a Video Camera ConnectionsVideo Typical Connection with the Sequential SwitcherTo REC TRIGG. OUT OutputContents of Screen Display Alarm Recall Screen Operation Setting the ClockDate-Time Display ON-SCREEN FunctionsVCR display Monitor screenDisplay Screen Is pressed. When an alarm is Alarm numberChanges to the alarm number This function enables to indicate and record informationWhen the tape reaches Alarm MemoryCounter Displays Counter MemoryRegarding the error code E-6 Display Error MessageTape Remain Code Number Condition of AbnormalityMode display Setting the RECORDING/PLAY Back TimeHOW to Operate 24 Hour Virtual Real Time Mode Unloading a Cassette Loading and Unloading a Video CassetteLoading a Cassette Camera and monitor TV Not been removed RecordingRestart Recording Setting the Restart RecordingSetting the Timer Program Timer RecordingDaily Timer Recording Program ScreenPress the Timer button Time Mode button is pressed, the displayShould be more than 1 minute. If they are same, timer During timer power off mode, alarm recording will notPress the Shift Button to blink the MO1 start time Weekly Timer RecordingPress the Shift ButtonGRAM.to blink PRO Example Overlapping ProgramsFR2 DLYOperation at Alarm Input Alarm RecordingAlarm Recall Display Event RecordingConnecting the Alarm Terminals Display Recording time Setting the Alarm RecordingCont ManualAuto Recording Connecting the External control terminalOperation of Auto Recording Auto recordingHow to Forbid Auto Recording How to Release Auto RecordingPress Timer button to release the timer mode Press the + or SETSetting contents Buzzer Screen display Counter display How to Set to Stop at End of TapeOperation After Tape END Detection Display Operation after detection of tape endMenu Screen How to Set to Auto Rewind at End of TapeAlarm recording does not operate during auto-rewind ButtonREC. to select REW → How to Set to Repeat Record at End of TapeConnection with the Sequential Switcher Recording with the Sequential SwitcherTiming for Camera Switching C D a B C DPress the Shift REC Trigger Output Selection in the Alarm RecordingButton to set the REC Trigger SELPlayback Tracking AdjustmentRecording time mode Time mode for playback REW Stop Using the Shuttle DialPicture Search Play Slow Still PlayPlayback in Various Modes Press the SET button to Set the Minute to Time Date SearchSearch Operation Still picture mode Press the Play button Alarm SearchAlarm M to light Input/Output terminal Signal level Additional remarks Signal Levels of INPUT/OUTPUT TerminalsPress the or Time Mode button to go to SPA2 mode Check the playback picture recorded in SPA2 modeDaily and Periodic Inspection Order of Daily ChecksTape Usage Frequency Steps to Take after Daily ChecksRequest for Periodic Checks Dew Condensation Installation Before Calling Service PersonnelFunction/Operation RecordingOther matters PlaybackConnector section SpecificationsAccessories Dew caution sheet70971826 Limited Warranty