The VCR can be programmed to automatically rewind the tape when the tape reaches its end.

How to Set to Auto Rewind at End of Tape

PREPARATION

Press the DISPLAY

1 button.

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

Press the + or – SET

4 buttonSTOP.to select REW

DISPLAY

TIME MODE +

 

SET

 

 

SHIFT

TRACKING

 

 

 

 

LOCATION SELECT

S E T U P

ALARM REC TIME

15S

SPEED

SPA 2

RESTART REC

OFF

TAPE END MODE

 

REWSTOP

ALARM

STOP

MENU=[DISPLAY]

Press the or SHIFT

2 button to blink SETUP and press the + SET button.

DISPLAY TIME MODE +

SET

 

SHIFT

TRACKING

 

 

LOCATION SELECT

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

Press the DISPLAY

5 buttondisplay.twice to erase the

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

8/28/97 THU 17:30:02SPA 2

RECORDING

OPERATION

Press the or SHIFT

3 button to blink TAPE END MODE.

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

S E T U P

 

 

ALARM REC TIME

15S

SPEED

SPA 2

RESTART REC

OFF

TAPE END MODE

STOP

 

ALARM

STOP

MENU=[DISPLAY]

iWhen tape end is detected during recording, the tape automatically rewinds and stops at beginning of the tape.

Caution:

If you need the VCR to Auto Rewind even if an alarm condi- tion occurred then set TAPE END ALARM to “CONT.” in the

MENU SCREEN.

PLAYBACK

OPERATION

NOTICE

Note:

iAlarm recording does not operate during auto-rewind.

35

Image 36
Contents Instruction Manual Important Precautions Please ReadImportant Safety Instructions Power SourcesRadiators, heat registers, stoves Unplug this product from the wallAccessories Power LinesWhen the power-supply cord or plug is damaged To restore the product to its normal operationFeatures Table of ContentsInstructions in Brief Front PanelTime Mode / SET + buttons Tape Remain buttonCassette Compartment Display buttonRear Panel Word on the Exclusive 3N-100AAS Battery Pack Specification of BatteryInstallation RemovalVCR Display REW button Press to start play backFF button Connections Connection with a Video CameraTypical Connection with the Sequential Switcher VideoTo REC TRIGG. OUT OutputContents of Screen Display Alarm Recall Screen Setting the Clock OperationON-SCREEN Functions Date-Time DisplayVCR display Monitor screenDisplay Screen Alarm number Is pressed. When an alarm isChanges to the alarm number This function enables to indicate and record informationAlarm Memory When the tape reachesCounter Displays Counter MemoryError Message Regarding the error code E-6 DisplayTape Remain Code Number Condition of AbnormalitySetting the RECORDING/PLAY Back Time HOW to Operate 24 Hour Virtual Real Time ModeMode display Loading and Unloading a Video Cassette Loading a CassetteUnloading a Cassette Recording Camera and monitor TV Not been removedSetting the Restart Recording Restart RecordingTimer Recording Setting the Timer ProgramDaily Timer Recording Program ScreenTime Mode button is pressed, the display Press the Timer buttonShould be more than 1 minute. If they are same, timer During timer power off mode, alarm recording will notWeekly Timer Recording Press the Shift ButtonGRAM.to blink PROPress the Shift Button to blink the MO1 start time Overlapping Programs ExampleFR2 DLYAlarm Recording Operation at Alarm InputAlarm Recall Display Event RecordingConnecting the Alarm Terminals Setting the Alarm Recording Display Recording timeCont ManualConnecting the External control terminal Auto RecordingOperation of Auto Recording Auto recordingHow to Release Auto Recording How to Forbid Auto RecordingPress Timer button to release the timer mode Press the + or SETHow to Set to Stop at End of Tape Setting contents Buzzer Screen display Counter displayOperation After Tape END Detection Display Operation after detection of tape endHow to Set to Auto Rewind at End of Tape Alarm recording does not operate during auto-rewindMenu Screen How to Set to Repeat Record at End of Tape ButtonREC. to select REW →Recording with the Sequential Switcher Connection with the Sequential SwitcherTiming for Camera Switching C D a B C DREC Trigger Output Selection in the Alarm Recording Press the ShiftButton to set the REC Trigger SELTracking Adjustment Recording time mode Time mode for playbackPlayback Using the Shuttle Dial REW StopPicture Search Play Slow Still PlayPlayback in Various Modes Time Date Search Search OperationPress the SET button to Set the Minute to Alarm Search Alarm M to lightStill picture mode Press the Play button Signal Levels of INPUT/OUTPUT Terminals Input/Output terminal Signal level Additional remarksCheck the playback picture recorded in SPA2 mode Press the or Time Mode button to go to SPA2 modeDaily and Periodic Inspection Order of Daily ChecksSteps to Take after Daily Checks Request for Periodic ChecksTape Usage Frequency Dew Condensation Before Calling Service Personnel InstallationFunction/Operation RecordingPlayback Other mattersSpecifications Connector sectionAccessories Dew caution sheetLimited Warranty 70971826