Toshiba kV-9960A Operation of Auto Recording, Connecting the External control terminal

Page 33

AUTO RECORDING

Auto Recording is convenient when it is necessary to activate recording with a trigger input while the unit is in either timer record or timer standby mode.

When there is a trigger input to the External Control terminal on the rear side, the unit will begin recording in the previously pro- grammed record mode.

Connecting the External control terminal

Auto recording

To external control

To GND

Consult with your dealer about the remote control switch.

INTRODUCTION

PREPARATION

Operation of Auto Recording

Press the DISPLAY

1 button.

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

Press the + or – SET

3 button.

DISPLAY

TIME MODE +

 

SET

 

 

SHIFT

TRACKING

 

 

 

 

LOCATION SELECT

iThen ON of MO1 line blinks on PROGRAM screen (1).

PROGRAM MO1 ON --:-- --:-- SP120 MO2 ON --:-- --:-- SP120 TU1 ON --:-- --:-- SP120 TU2 ON --:-- --:-- SP120 WE1 ON --:-- --:-- SP120 WE2 ON --:-- --:-- SP120 TH1 ON --:-- --:-- SP120 TH2 ON --:-- --:-- SP120

MENU=[DISPLAY]

Press the or SHIFT

2 buttonGRAM.to blink PRO-

DISPLAY TIME MODE +

M E N U

CLOCK ADJUST SETUP DISPLAY MODE

PROGRAM

Press the SHIFT

4 button to proceed to PROGRAM screen (2).

DISPLAY TIME MODE +

PROGRAM FR1 ON --:-- --:-- SP120 FR2 ON --:-- --:-- SP120 SA1 ON --:-- --:-- SP120 SA2 ON --:-- --:-- SP120 SU1 ON --:-- --:-- SP120

SET

SHIFT

TRACKING

ALARM RECALL TIME DATE SEARCH

SET

SHIFT

TRACKING

 

SU2 ON --:-- --:-- SP120

DLY ON --:-- --:-- SP120

LOCATION SELECT

END=[DISPLAY]

LOCATION SELECT

EXT ON

 

SP120

 

MENU=[DISPLAY]

PLAYBACK

OPERATION

NOTICE

32

Image 33
Contents Instruction Manual Please Read Important PrecautionsPower Sources Important Safety InstructionsRadiators, heat registers, stoves Unplug this product from the wallPower Lines AccessoriesWhen the power-supply cord or plug is damaged To restore the product to its normal operationTable of Contents FeaturesFront Panel Instructions in BriefTape Remain button Time Mode / SET + buttonsCassette Compartment Display buttonRear Panel Specification of Battery Word on the Exclusive 3N-100AAS Battery PackInstallation RemovalVCR Display REW button Press to start play backFF button Connection with a Video Camera ConnectionsVideo Typical Connection with the Sequential SwitcherTo REC TRIGG. OUT OutputContents of Screen Display Alarm Recall Screen Operation Setting the ClockDate-Time Display ON-SCREEN FunctionsVCR display Monitor screenDisplay Screen Is pressed. When an alarm is Alarm numberChanges to the alarm number This function enables to indicate and record informationWhen the tape reaches Alarm MemoryCounter Displays Counter MemoryRegarding the error code E-6 Display Error MessageTape Remain Code Number Condition of AbnormalitySetting the RECORDING/PLAY Back Time HOW to Operate 24 Hour Virtual Real Time ModeMode display Loading and Unloading a Video Cassette Loading a CassetteUnloading a Cassette Camera and monitor TV Not been removed RecordingRestart Recording Setting the Restart RecordingSetting the Timer Program Timer RecordingDaily Timer Recording Program ScreenPress the Timer button Time Mode button is pressed, the displayShould be more than 1 minute. If they are same, timer During timer power off mode, alarm recording will notWeekly Timer Recording Press the Shift ButtonGRAM.to blink PROPress the Shift Button to blink the MO1 start time Example Overlapping ProgramsFR2 DLYOperation at Alarm Input Alarm RecordingAlarm Recall Display Event RecordingConnecting the Alarm Terminals Display Recording time Setting the Alarm RecordingCont ManualAuto Recording Connecting the External control terminalOperation of Auto Recording Auto recordingHow to Forbid Auto Recording How to Release Auto RecordingPress Timer button to release the timer mode Press the + or SETSetting contents Buzzer Screen display Counter display How to Set to Stop at End of TapeOperation After Tape END Detection Display Operation after detection of tape endHow to Set to Auto Rewind at End of Tape Alarm recording does not operate during auto-rewindMenu Screen ButtonREC. to select REW → How to Set to Repeat Record at End of TapeConnection with the Sequential Switcher Recording with the Sequential SwitcherTiming for Camera Switching C D a B C DPress the Shift REC Trigger Output Selection in the Alarm RecordingButton to set the REC Trigger SELTracking Adjustment Recording time mode Time mode for playbackPlayback REW Stop Using the Shuttle DialPicture Search Play Slow Still PlayPlayback in Various Modes Time Date Search Search OperationPress the SET button to Set the Minute to Alarm Search Alarm M to lightStill picture mode Press the Play button Input/Output terminal Signal level Additional remarks Signal Levels of INPUT/OUTPUT TerminalsPress the or Time Mode button to go to SPA2 mode Check the playback picture recorded in SPA2 modeDaily and Periodic Inspection Order of Daily ChecksSteps to Take after Daily Checks Request for Periodic ChecksTape Usage Frequency Dew Condensation Installation Before Calling Service PersonnelFunction/Operation RecordingOther matters PlaybackConnector section SpecificationsAccessories Dew caution sheet70971826 Limited Warranty