Toshiba kV-9960A Alarm Search, Alarm M to light, Still picture mode Press the Play button

Page 44

INTRODUCTION

ALARM SEARCH

With the alarm search function, it is possible to search for alarm that has been recorded on the tape.

PREPARATION

Search Operation

1 Press the STOP button.

H

ALARM

REC SP

PLAY

 

STOP

2

Press the COUNTER MEMORY button twice to make

“ALARM M” to light.

ALARM

ALARM

H

 

 

M

 

 

 

 

SP

 

 

COUNTER

 

 

 

MEMORY ALARM RESET

 

 

 

Turn the SHUTTLE dial to set rewind or fast forward.

3

 

ALARM

ALARM

H

PLAY

M

 

 

SP

 

REV

FWD

When the tape reaches the

 

 

alarm recorded position, The

 

 

VCR automatically enters the

 

 

still picture mode.

 

4 Press the PLAY button.

 

 

 

PLAY

STOP

 

 

 

PLAYBACK

OPERATION

 

 

NOTICE

Notes:

In the cases shown below, Alarm Memory search may be not carried out.

iIf the alarm recording is not carried out for more than those listed in the following chart then, the alarm may be skipped.

iIf the alarm recording interval is not left for more than those listed in the following chart then, the alarm may be skipped.

iIf there is not enough time between the beginning of the alarm search and the first alarm activation. If the time period is shorter than those listed in the following chart then, the first alarm may be skipped.

Record

Minimum alarm recording time

Minimum alarm recording interval

Minimum recording time needed between start of

mode

needed

needed

search and first alarm activations

SPA2 or EPA6

2 s

7 s

5 s

SPA12

15 s

50 s

35 s

EPA18

7 s

25 s

15 s

SPA24

30 s

95 s

65 s

 

 

 

 

43

Image 44
Contents Instruction Manual Important Precautions Please ReadImportant Safety Instructions Power SourcesRadiators, heat registers, stoves Unplug this product from the wallAccessories Power LinesWhen the power-supply cord or plug is damaged To restore the product to its normal operationFeatures Table of ContentsInstructions in Brief Front PanelTime Mode / SET + buttons Tape Remain buttonCassette Compartment Display buttonRear Panel Word on the Exclusive 3N-100AAS Battery Pack Specification of BatteryInstallation RemovalVCR Display FF button REW buttonPress to start play back Connections Connection with a Video CameraTypical Connection with the Sequential Switcher VideoTo REC TRIGG. OUT OutputContents of Screen Display Alarm Recall Screen Setting the Clock OperationON-SCREEN Functions Date-Time DisplayVCR display Monitor screenDisplay Screen Alarm number Is pressed. When an alarm isChanges to the alarm number This function enables to indicate and record informationAlarm Memory When the tape reachesCounter Displays Counter MemoryError Message Regarding the error code E-6 DisplayTape Remain Code Number Condition of AbnormalityMode display Setting the RECORDING/PLAY Back TimeHOW to Operate 24 Hour Virtual Real Time Mode Unloading a Cassette Loading and Unloading a Video CassetteLoading a Cassette Recording Camera and monitor TV Not been removedSetting the Restart Recording Restart RecordingTimer Recording Setting the Timer ProgramDaily Timer Recording Program ScreenTime Mode button is pressed, the display Press the Timer buttonShould be more than 1 minute. If they are same, timer During timer power off mode, alarm recording will notPress the Shift Button to blink the MO1 start time Weekly Timer RecordingPress the Shift ButtonGRAM.to blink PRO Overlapping Programs ExampleFR2 DLYAlarm Recording Operation at Alarm InputAlarm Recall Display Event RecordingConnecting the Alarm Terminals Setting the Alarm Recording Display Recording timeCont ManualConnecting the External control terminal Auto RecordingOperation of Auto Recording Auto recordingHow to Release Auto Recording How to Forbid Auto RecordingPress Timer button to release the timer mode Press the + or SETHow to Set to Stop at End of Tape Setting contents Buzzer Screen display Counter displayOperation After Tape END Detection Display Operation after detection of tape endMenu Screen How to Set to Auto Rewind at End of TapeAlarm recording does not operate during auto-rewind How to Set to Repeat Record at End of Tape ButtonREC. to select REW →Recording with the Sequential Switcher Connection with the Sequential SwitcherTiming for Camera Switching C D a B C DREC Trigger Output Selection in the Alarm Recording Press the ShiftButton to set the REC Trigger SELPlayback Tracking AdjustmentRecording time mode Time mode for playback Using the Shuttle Dial REW StopPicture Search Play Slow Still PlayPlayback in Various Modes Press the SET button to Set the Minute to Time Date SearchSearch Operation Still picture mode Press the Play button Alarm SearchAlarm M to light Signal Levels of INPUT/OUTPUT Terminals Input/Output terminal Signal level Additional remarksCheck the playback picture recorded in SPA2 mode Press the or Time Mode button to go to SPA2 modeDaily and Periodic Inspection Order of Daily ChecksTape Usage Frequency Steps to Take after Daily ChecksRequest for Periodic Checks Dew Condensation Before Calling Service Personnel InstallationFunction/Operation RecordingPlayback Other mattersSpecifications Connector sectionAccessories Dew caution sheetLimited Warranty 70971826