Toshiba kV-9960A instruction manual Setting the Restart Recording

Page 25

RESTART RECORDING

Setting the Restart Recording

On the SETUP screen set RESTART REC to ON.

INTRODUCTION

Press the DISPLAY

1 button. The MENU screen appears on the monitor screen.

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

PREPARATION

Press the or SHIFT

2 button to blink SETUP and press the + or – SET button.

DISPLAY

TIME MODE +

 

SET

 

 

SHIFT

TRACKING

 

 

 

 

LOCATION SELECT

M E N U

CLOCK ADJUST SETUP DISPLAY MODE PROGRAM ALARM RECALL TIME DATE SEARCH

END=[DISPLAY]

Press the or SHIFT

3 buttonREC. to blink RESTART

DISPLAY TIME MODE +

SET

SHIFT

TRACKING

 

 

LOCATION SELECT

S E T U P

 

 

ALARM REC TIME

15S

SPEED

SPA 2

RESTART REC

OFF

 

TAPE END MODE

STOP

ALARM

STOP

MENU=[DISPLAY]

Press the + or – SET

4 button to go to ON.

DISPLAY

TIME MODE +

 

SET

 

 

SHIFT

TRACKING

 

 

 

 

LOCATION SELECT

S E T U P

 

 

ALARM REC TIME

15S

SPEED

SPA 2

RESTART REC

ON

 

TAPE END MODE

STOP

ALARM

STOP

MENU=[DISPLAY]

PLAYBACK

OPERATION

Notes:

iWhen a power failure occurs (10 days or less in duration) during recording or timer recording, the VCR resumes automatically to the same mode when the power is restored regardless of whether “RESTART REC” is ON or OFF.

iWhen the power is recovered after more than 10 days have passed, the tape remains at the position where it stopped when the power failure occurred.

NOTICE

24

Image 25
Contents Instruction Manual Please Read Important PrecautionsPower Sources Important Safety InstructionsRadiators, heat registers, stoves Unplug this product from the wallPower Lines AccessoriesWhen the power-supply cord or plug is damaged To restore the product to its normal operationTable of Contents FeaturesFront Panel Instructions in BriefTape Remain button Time Mode / SET + buttonsCassette Compartment Display buttonRear Panel Specification of Battery Word on the Exclusive 3N-100AAS Battery PackInstallation RemovalVCR Display Press to start play back REW buttonFF button Connection with a Video Camera ConnectionsVideo Typical Connection with the Sequential SwitcherTo REC TRIGG. OUT OutputContents of Screen Display Alarm Recall Screen Operation Setting the ClockDate-Time Display ON-SCREEN FunctionsVCR display Monitor screenDisplay Screen Is pressed. When an alarm is Alarm numberChanges to the alarm number This function enables to indicate and record informationWhen the tape reaches Alarm MemoryCounter Displays Counter MemoryRegarding the error code E-6 Display Error MessageTape Remain Code Number Condition of AbnormalityHOW to Operate 24 Hour Virtual Real Time Mode Setting the RECORDING/PLAY Back TimeMode display Loading a Cassette Loading and Unloading a Video CassetteUnloading a Cassette Camera and monitor TV Not been removed RecordingRestart Recording Setting the Restart RecordingSetting the Timer Program Timer RecordingDaily Timer Recording Program ScreenPress the Timer button Time Mode button is pressed, the displayShould be more than 1 minute. If they are same, timer During timer power off mode, alarm recording will notPress the Shift ButtonGRAM.to blink PRO Weekly Timer RecordingPress the Shift Button to blink the MO1 start time Example Overlapping ProgramsFR2 DLYOperation at Alarm Input Alarm RecordingAlarm Recall Display Event RecordingConnecting the Alarm Terminals Display Recording time Setting the Alarm RecordingCont ManualAuto Recording Connecting the External control terminalOperation of Auto Recording Auto recordingHow to Forbid Auto Recording How to Release Auto RecordingPress Timer button to release the timer mode Press the + or SETSetting contents Buzzer Screen display Counter display How to Set to Stop at End of TapeOperation After Tape END Detection Display Operation after detection of tape endAlarm recording does not operate during auto-rewind How to Set to Auto Rewind at End of TapeMenu Screen ButtonREC. to select REW → How to Set to Repeat Record at End of TapeConnection with the Sequential Switcher Recording with the Sequential SwitcherTiming for Camera Switching C D a B C DPress the Shift REC Trigger Output Selection in the Alarm RecordingButton to set the REC Trigger SELRecording time mode Time mode for playback Tracking AdjustmentPlayback REW Stop Using the Shuttle DialPicture Search Play Slow Still PlayPlayback in Various Modes Search Operation Time Date SearchPress the SET button to Set the Minute to Alarm M to light Alarm SearchStill picture mode Press the Play button Input/Output terminal Signal level Additional remarks Signal Levels of INPUT/OUTPUT TerminalsPress the or Time Mode button to go to SPA2 mode Check the playback picture recorded in SPA2 modeDaily and Periodic Inspection Order of Daily ChecksRequest for Periodic Checks Steps to Take after Daily ChecksTape Usage Frequency Dew Condensation Installation Before Calling Service PersonnelFunction/Operation RecordingOther matters PlaybackConnector section SpecificationsAccessories Dew caution sheet70971826 Limited Warranty