SterlingTEK A0551797 manual Typical Two-Circuit 60-100 Ton Water Cooled Chiller, Model SSCW-xxx

Page 11

Figure 1

Typical Two-Circuit 60-100 Ton Water Cooled Chiller

Model

 

 

 

SSCW-xxx

 

 

 

30

 

40

50

 

60

 

 

 

 

Cooling Capacity (tons) @ 50°F (10°C) LWT •

32.4

 

41.4

50.2

 

64.8

Capacity stages (qty.)

 

 

2

 

4

EER (BTUH/W)

 

15.65

 

14.91

15.35

 

15.66

Nominal water flow (gpm)

Evaporator ‚

78 [295.3]

 

99 [374.8]

120 [454.2]

 

156 [590.5]

[lpm]

Condensers ƒ

97 [367.2]

 

124 [469.4]

151 [571.6]

 

194 [734.4]

Condenser connection (no

manifold) Flange Conn. (in.)

(2) 2

 

(2) 2

(2) 2

 

(2) 2 1/2

Evaporator manifold connection Victaulic

3

 

3

3

 

3

Amp draw, nameplate (460/3/60 V) „

56

 

70

88

 

111

Dimensions (in.)[cm]

Height

 

 

85 [215.9]

 

 

Width

66 [167.6]

94 [238.8]

 

Depth

 

45 [114.3]

 

 

Shipping weight (lbs)[kg]

 

1,520

 

1,900

2,120

 

2,700

 

 

[689.5]

 

[861.8]

[961.6]

 

[1224.7]

Max operating weight (lbs.)[kg]

1,610

 

2,010

2,260

 

2,870

 

 

[730.3]

 

[911.7]

[1025.1]

 

[1301.8]

SSC Series Central Chilling Stations

Page 11 of 86

Image 11
Contents SSC Series Central Chilling Stations SSC Series Central Chilling Stations Wear Safety Glasses and Work Gloves Safety ConsiderationsTable of Contents Getting Started on the SSC Series Advanced Touchscreen Startup ChecklistsCharts and Figures Necessary Documents IntroductionModels Covered Standard FeaturesAvailable Options Standard Features on Remote CondensersModel Number Nomeclature Model SSCW-xxx Typical Two-Circuit 60-100 Ton Water Cooled ChillerCooling Capacity tons @ 50F 10 C LWT 73.1 81.4 Model SSCR-xxx Typical Two-Circuit 60-100 Ton Remote Air Cooled ChillerSscr Series Remote Condenser Models Event of Shipping Damages Unpacking and InspectionReturns If the Shipment is Not CompleteIf the Shipment is Not Correct Uncrating Your New Chiller SSC Series Central Chilling Stations Making Electrical Connections 3InstallationInstallation Location Considerations SSC Series Central Chilling Stations All Models Piping ConsiderationsMaking Process Water Connections From Process Making Tank Piping ConnectionsMaking Water-Cooled Condenser Connections Water Connection Sizing ConsiderationsGalvanic Corrosion Considerations Water Treatment ConsiderationsCondenser Water Installing the Remote Air-Cooled CondenserCompressor Checking Motor DirectionSSC Series Central Chilling Stations Lead-Lag Pumps AlarmsStaging Lead-Lag CompressorsFreezestat Control Chilled Water CircuitRefrigeration Circuit Freezing Protection Curve VolumeLow Pressure Cutout Flow SwitchHigh Pressure Cutout Condenser Water Manifold Control NippleControl Probe Chilled Water ManifoldSSC Series Central Chilling Stations Water-Cooled SSC Series Startup Checklist Startup ChecklistsSSC Series Central Chilling Stations Water-Cooled SSC Series Startup Remote Air-Cooled SSC Series Startup ChecklistSSC Series Central Chilling Stations Remote Air-Cooled SSC Series Startup Shutdown Determining Flow RateSSC Series Central Chilling Stations SSC Series Central Chilling Stations Graphic Panel Devices Indicator Lights and Control Switches MMISSC Series Central Chilling Stations Touchscreen Interface Introduction MMI Using the StandardTouchscreen Interface SSC Series Standard Control Panel Using the SSC Series Standard Touchscreen InterfaceMain Menu Screen Compressor Status Screen Viewing and Operating Chiller CompressorsViewing Compressor Status Operating the chiller compressors Chiller Configuration ScreenCompressor Lead/Lag Screen Compressor Enable ScreenCompressor Run Time Display Screen Viewing Compressor Run TimesPump Status Screen Viewing and Operating Chiller PumpsViewing Chiller Pump Status Operating Chiller Pumps Pump Enables ScreenPump Run Time Display Screen Viewing Pump Run TimesPump Lead/Lag Screen Alarm Condition Screen Viewing Active Alarms and Handling Alarm ConditionsOr Death Setting System Temperatures Viewing and Setting System TemperaturesSSC Series Central Chilling Stations Using the Advanced Using the SSC Series Advanced Touchscreen Interface Main Menu Screen Viewing and Operating Chiller Compressors Chiller Status Screen Operating the chiller compressors Viewing Compressor Run Times Viewing and Operating Chiller Pumps Viewing Chiller Pump Status Operating Chiller Pumps Hourmeters Pump Run Time screen displays Viewing Active Alarms and Handling Alarm Conditions Alarm Condition Screen Or Death System Status Screen Temperature Input Display Screen Lubrication Condenser MaintenanceRecommended Pump Tank Spare Parts Evaporator MaintenancePump Motor Seal Makeup ValvePreventive Maintenance Service SSC Series Central Chilling Stations Problem Possible Cause Solution 10TroubleshootingAllow time to cool and reset Verify proper rotation if Service Notes Index Water Treatment Service Notes Service Notes Service Notes Sterling Th Street New Berlin, WI 262 641-8610 ∙ Fax 262 Parts Department