Linear VS-GSWG manual Variable Speed Drive Programming, Programming the Hitachi Inverter

Page 31

Variable Speed Drive Programming

CAUTION

This unit has been programmed at the factory. No changes should be necessary for normal operation. PLEASE CONSULT THE FACTORY BEFORE MAKING ANY CHANGES!

Programming the Hitachi Inverter

1.Apply power

2.Press FUNC

3.Use ▲▼ arrows to advance to F_ _ (F002 for L200)

4.Press FUNC arrow to get to F02 (L100 ONLY)

5.Press FUNC, arrows to change to 3.0 (3.00 for L200),

STR

6.Up arrow to advance to next parameter, (F03), FUNC to view, arrows to change, STR to store and continue, advance through listed parameters and store new values.

7.To switch from one letter prefi x to another, press FUNC 3 times, advance to desired letter prefi x, press FUNC, advance to desired parameter.

8.When all parameters have been changed, advance to D01, press FUNC, then press STR. This will display the operating speed in Hz. (0-95)

NOTE: L200 model

NOTE: L200 model must

must have this switch in

have these two switches

the UP (SR) position.

in the DOWN position.

Figure 14. Hitachi L200 Inverter

List of parameters set at factory

MODEL L100

MODEL L200

FUNCTION

DESCRIPTION

RECOMMENDED

FUNCTION

DESCRIPTION

 

RECOMMENDED

SETTING

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

F02

ACCEL TIME

3.0

F002

ACCEL TIME

3.00

 

 

 

 

 

 

F03

DECEL TIME

3.0

F003

DECEL TIME

3.00

 

 

 

 

 

 

 

A01

SPEED SOURCE

00 (POT)

A001

SPEED SOURCE

00

(POT)

 

 

 

 

 

 

 

A02

RUN COMMAND SOURCE

01

A002

RUN COMMAND SOURCE

01

 

 

 

 

 

 

 

 

A04

MAX SPEED

95.0 (Hz)

A004

MAX SPEED

95

(Hz)

 

 

 

 

 

 

A20

TARGET SPEED

95.0 (Hz)

A020

TARGET SPEED

95.0 (Hz)

 

 

 

 

 

 

A21

SECOND SPEED

20.0 (Hz)

A021

SECOND SPEED

20.0 (Hz)

 

 

 

 

 

 

 

 

 

 

A042

AUTO TORQUE BOOST

0

 

 

 

 

 

 

 

 

 

 

 

A044

BOOST PERCENT

00

 

 

 

 

 

 

 

 

 

 

 

A081

AUTO VOLTAGE

01

 

 

 

 

 

REGULATION

 

 

 

 

 

 

 

 

A62

MIN SPEED

20.0 (Hz)

A062

MIN SPEED

20.0 (Hz)

 

 

 

 

 

 

 

B01

AUTO RESET

01

B001

AUTO RESET

01

 

 

 

 

 

 

 

 

 

 

 

B130

INHIBIT DECEL

01

 

 

 

 

 

OVERVOLTAGE

 

 

 

 

 

 

 

 

 

C03

TERM 3 FUNC

03

C003

TERM 3 FUNC

03

 

 

 

 

 

 

 

 

C04

TERM 4 FUNC

11

C004

TERM 4 FUNC

11

 

 

 

 

 

 

 

 

 

 

 

C014

TERM 4 STATE

01

 

 

 

 

 

 

 

 

VS-GSWG Swing Gate Operator Installation Guide

- 29 -

P1250 Revision X6 7-8-2011

 

Image 31
Contents VS-GSWG Table of Contents Safety Information and Warnings Pre-installation InformationAC Power Wiring Wiring SpecificationsDC Control and Accessory Wiring Gate Preparation Mounting Pad InstallationMounting Specifications Operator Preparation Gate Arm InstallationVent Plug Installation Gate Arm AssemblyEarth Ground Operator SetupController Access AC Power ConnectionSetting Speeds using LSO-2 & LSC-2 Open and Close Limit AdjustmentLimit Nuts Rough Adjustment Limit Nuts Fine AdjustmentLoosen the set screw on the adjustment nut Torque Limiter AdjustmentButtons Controller FeaturesApex Function Display Indications Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Maximum Open Direction Current Setting Run Alarm and Pre-start AlarmMaximum Close Direction Current Setting Advanced Controller Programming Constant Pressure Mode Auxiliary Relay ModeReverse Delay Time Brake Delay TimeRadio Enable Reset Cycle CountMaintenance Alert Trigger Anti-tailgate EnableMGT Obstacle Transmitter Learn Reset Controller to Factory DefaultsRadio Transmitter Learn Radio Transmitter DeleteLoop Layout Illustration Safety Edge Layout Illustration Photoeye Installation Illustration Open and Close Limit settings Dual Gate InstallationsOptional In-Cabinet Heater Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting General Preventative MaintenanceMonth Preventative Maintenance FCC NoticeModel VS-GSWG Exploded View Model SWG Mechanical Parts List Variable Speed Control Box Assemblies Controller Parts ListProgramming the Hitachi Inverter Variable Speed Drive ProgrammingShown for Clarity only not Included in ARM Assembly Gate Arm Assembly Parts ListThis page left blank intentionally Gate Operator Installation Checklist