Linear VS-GSWG manual Preventative Maintenance, FCC Notice, General, Lubrication

Page 27

Preventative Maintenance

WARNING

Always disconnect power from operator before servicing. Keep clear of gate during operation.

General

Linear gate operators are designed for many years of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance. To ensure that a unit is ready for operation at all times, and to preclude serious damage or failure, inspect the unit systematically. Proper adjustments and lubrication should be made as recommended.

Lubrication

Bearings — For models which have pillow block style bearings with grease fi ttings, lubricate at least twice a year with a lithium complex based, petroleum oil NLGI 2 rated grease. Oilite and precision sealed bearings do not require additional lubrication.

Motor — Motors have sealed ball bearings and do not require further lubrication. If bearing noise develops after several years of operation, bearings should be replaced by a motor repair company, or the motor should be replaced if necessary.

Swing Gate Arm — Check all bolts for proper tension and tighten if necessary. Lightly lubricate all pivot points with a light machine oil.

For all gate operators, you must inspect the gate for proper operation. The gate should move easily without binding through its entire travel. If the gate does bind, adjust or fix as required. Failure to keep the gate in good working condition will have adverse effects on the operator.

6-Month Preventative Maintenance

1.For operators which utilize torque limiting clutches, check for proper tightness. If there appears to be dust from wear on the pads, inspect the pads and replace if necessary. If the clutch cannot be adjusted tightly enough to move the gate without slipping, the pads must be replaced.

2.For operators with V-belts, inspect for wear and replace as necessary. Check for proper tension and adjust if required. Check all pulley setscrews for tightness and tighten if necessary.

3.For operators with internal chain drives, inspect chain and sprockets for wear and replace if necessary. Check for proper tension and alignment, and adjust if required. Check all hub sprocket setscrews and tighten if required.

4.Check limit switches and limit actuators (cams, limit nuts, etc.) for wear and replace as required. In rotary limit switch assemblies, wipe the limit shaft clean and apply a light coating of dry lubricant.

5.For operators with magnetic brakes, check for proper adjustment. Brake disc must run free when the brake is engaged. For brake assemblies other than C-face style, the brake should be adjusted so that the solenoid plunger throw is between 3/8” to 1/2”. Too much throw will damage the solenoid. If the solenoid emits a loud buzzing sound when the motor is run, the brake must be adjusted.

6.In operators which have a disconnect handle, inspect disconnect handle for proper function and lubricate if necessary. Use a lithium based grease on all moving parts.

7.Inspect all nuts and bolts for proper tightness and tighten as necessary.

8.Check all reversing devices for proper function. Inspect all contact edges for wear and replace if required. Check photoeyes for proper alignment and function.

9. Check current sensing for proper adjustment when

fi nished with inspection and maintenance.

10.Inspect the installation area. Are all the warning signs intact and visible? If they are missing or need replaced, contact Linear. Be sure there are no control stations mounted within reach of the gate. Review safety literature with the customer and advise them to remove any such stations found.

FCC Notice

This device complies with FCC Rules Part 15 and Industry Canada Rules & Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

VS-GSWG Swing Gate Operator Installation Guide

- 25 -

P1250 Revision X6 7-8-2011

 

Image 27
Contents VS-GSWG Table of Contents Safety Information and Warnings Pre-installation InformationWiring Specifications AC Power WiringDC Control and Accessory Wiring Mounting Pad Installation Gate PreparationMounting Specifications Operator Preparation Gate Arm InstallationVent Plug Installation Gate Arm AssemblyEarth Ground Operator SetupController Access AC Power ConnectionSetting Speeds using LSO-2 & LSC-2 Open and Close Limit AdjustmentLimit Nuts Rough Adjustment Limit Nuts Fine AdjustmentLoosen the set screw on the adjustment nut Torque Limiter AdjustmentButtons Controller FeaturesApex Function Display Indications Indicator DescriptionsTerminal Group Function Terminal DescriptionsOperator Accessory Connections Operator Accessory ConnectionsBasic Controller Programming Run Alarm and Pre-start Alarm Maximum Open Direction Current SettingMaximum Close Direction Current Setting Advanced Controller Programming Constant Pressure Mode Auxiliary Relay ModeReverse Delay Time Brake Delay TimeRadio Enable Reset Cycle CountMaintenance Alert Trigger Anti-tailgate EnableMGT Obstacle Transmitter Learn Reset Controller to Factory DefaultsRadio Transmitter Learn Radio Transmitter DeleteLoop Layout Illustration Safety Edge Layout Illustration Photoeye Installation Illustration Dual Gate Installations Open and Close Limit settingsOptional In-Cabinet Heater Operation Indications Gate OperationMGT Obstacle Transmitter Trouble Error IndicationsEntrapment Comm Link Connection FailureTroubleshooting General Preventative MaintenanceMonth Preventative Maintenance FCC NoticeModel VS-GSWG Exploded View Model SWG Mechanical Parts List Variable Speed Control Box Assemblies Controller Parts ListProgramming the Hitachi Inverter Variable Speed Drive ProgrammingShown for Clarity only not Included in ARM Assembly Gate Arm Assembly Parts ListThis page left blank intentionally Gate Operator Installation Checklist